Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Photonics

Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution

Wenzhao Huang, Zifu Su, Weiqian Zhao, Yafei Yu, Jindong Wang, Zhengjun Wei

Published Mar 30, 2026• 0 citations
Publisher

Abstract

Weak measurement enables the amplification of weak physical effects via post-selection and has become an important tool in precision optical metrology; however, conventional schemes based on mean-pointer shifts suffer from response saturation, limited linear range, and stringent stability requirements. Here, we propose and experimentally demonstrate a weak-measurement scheme based on spectral-interference trough shifts, where the zero-intensity points of the post-selected spectrum act as the measurement pointer, establishing an analytical mapping between the trough displacement and the target phase or time delay. Theoretical analysis shows that, under detector resolution limits, the measurement resolution depends solely on the frequency of extinction point and is independent of weak-value singular amplification or bias-phase modulation, thereby maintaining high sensitivity while avoiding pointer saturation. Experiments demonstrate that the trough-shift scheme achieves significantly better agreement between measured and theoretical sensitivities than biased weak measurement and provides a stable linear response without additional bias-compensation structures, reaching a minimum resolvable phase variation at the 10−7 level. Moreover, the approach intrinsically supports multi-period traceable measurements and exhibits strong robustness against intensity fluctuations and spectral distortions, offering a promising route toward high-sensitivity, large-dynamic-range, and stable weak measurement-based optical sensing.

DOI
10.3390/photonics13040336

Related papers

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•6 citations

Weak-value-amplification metrology without spectral analysis

Jingzheng Huang, Chen Fang, Guihua Zeng

We propose a scheme called difference weak measurement, and we illustrate its advantages for measuring a small longitude phase shift in high precision. Compared to the standard interferometry and standard weak measurement schemes, the proposed scheme has a much higher resolution in the presence of various practical imperfections, such as alignment error and light intensity variation error. Moreover, we highlight the advantage of utilizing a complex weak value, where its imaginary part can reduce the harmful effect induced by channel decoherence. Finally, we propose a closed-loop scenario to solve the narrow dynamic range problem that exists in the current weak measurement schemes. The difference weak measurement scheme simultaneously fulfills the requirements of high precision, wide dynamic range, and strong robustness, which makes it a powerfully practical tool for phase-shift measurement and other metrological tasks.

arXiv:1803.08637•Physical Review A•Jun 26, 2018•15 citations

Retaining high precision and sensitivity for an extended range of phase estimation via modulated weak measurement

Zhaoxue Li, Jiangdong Qiu, Linguo Xie +5 more

We theoretically propose and experimentally demonstrate a modulated weak measurement scheme that permits a precise estimation of the extended phase shift. By choosing the frequency and the total post-selected light intensity as the input and output meter variables, respectively, a linear weak measurement model is established that is especially applicable to precise phase estimation. By performing a time-delay-dependent modulation strategy based on the feedback modulation of the experimental outcome, both the high phase-sensitivity and measurement precision can be retained. We have achieved a precision at the order of ∼10−5 rad that can be effectively retained with an increase in the measured phase.

Applied Physics Letters•Nov 5, 2018•14 citations

Adaptive Biased Weak Measurement for Robust High-Precision Phase Estimation

Lan Zhong, Yu-Fan Zhang, Wen‐Hao Zhang +2 more

Abstract Quantum metrology has emerged as a crucial paradigm for enhancing measurement sensitivity beyond classical limits. While standard weak measurement and static biased phase methods can effectively amplify extremely small signals, they fundamentally suffer from a trade-off between postselection probability and linear response range, leaving them vulnerable to parameter drift. Motivated by realistic experimental applications such as measuring optical birefringence or thickness using a polarization-frequency Sagnac interferometer, we propose an adaptive biased weak measurement (ABWM) scheme that combines the sensitivity enhancement of biased weak measurement with a feedback-assisted adjustment of the bias phase. By dynamically updating the bias phase in response to measurement outcomes, the system can track slow parameter variations and maintain nearoptimal estimation precision. Numerical simulations under technical noise demonstrate reliable convergence from multiple random initial bias phases and show that the proposed adaptive- β strategy achieves more accurate dynamic tracking than standard weak measurement and static biased weak measurement. Our results suggest that ABWM provides a flexible and resource-efficient strategy for high-precision quantum metrology in realistic experimental scenarios.

Chinese Physics B•Jul 30, 2026•0 citations

Weak-measurement method for surface-roughness estimation

Hui-Chao Qu, Ya Xiao, Zhao-Qi-Zhi Han +2 more

High-precision surface-roughness estimation plays an important role in many applications. However, the classical estimating methods are limited by shot noise and can only achieve a precision of 0.1 nm with a white-light interferometer. Here, we propose two weak-measurement schemes to estimate surface roughness through a spectrum analysis and intensity analysis. The estimating precision with the spectrum analysis is about ${10}^{\ensuremath{-}5}$ nm by using a currently available spectrometer with a resolution of $\mathrm{\ensuremath{\Delta}}\ensuremath{\lambda}=0.04$ pm and the corresponding sensitivity is better than 0.1 THz/nm. The precision and sensitivity of the light intensity analysis scheme achieved is as high as 0.07 nm and 1/nm, respectively. By introducing a modulated phase, we show that the sensitivity and precision achieved in our schemes can be effectively retained in a wider dynamic range. We further provide the experimental design of a surface profiler based on our schemes. It simultaneously meets the requirements of high precision, high sensitivity, and a wide measurement range, making it a promising practical tool.

arXiv:2202.13644•Physical Review A•Jun 10, 2022•3 citations

Practical sub-nanometer optical path difference metrology using biased weak measurement with real weak values

Huang Jing-Hui, Jing-zheng Huang, Hongliang Cui +5 more

We experimentally demonstrate a sub-nanometer optical path difference (OPD) metrology scheme based on biased weak measurement (BWM) with real weak values using a classical coherent light source. By introducing a controlled bias phase in a Mach-Zehnder interferometric configuration, the proposed approach enables enhanced detection of sub-nanometer OPD variations while maintaining compatibility with common optical components and narrowband light sources. We systematically compare the measurement response, sensitivity, and signal-to-noise ratio (SNR) of BWM with those of standard weak measurement (SWM) and conventional interferometric measurement (CM) under identical experimental conditions. Relative to SWM, BWM provides an approximately fourfold enhancement in measurement response within the linear operating range, while achieving a (94 ± 10)-fold signal amplification compared with CM. Furthermore, the measured SNR exhibits an order-of-magnitude improvement over CM under detector-saturation-limited measurement conditions. Experimentally, the BWM scheme achieves a minimum detectable OPD of (5.6 ± 0.36) × 10 −4 nm, obtained from Allan deviation analysis. These results highlight the potential of weak measurement as a practical strategy for high-precision optical path metrology and precision interferometric sensing.

Optics Express•Aug 25, 2026•0 citations
Weak measurement enables the amplification of weak physical effects via post-selection and has become an important tool in precision optical metrology; however, conventional schemes based on mean-pointer shifts suffer from response saturation, limited linear range, and stringent stability requirements. Here, we propose and experimentally demonstrate a weak-measurement scheme based on spectral-interference trough shifts, where the zero-intensity points of the post-selected spectrum act as the measurement pointer, establishing an analytical mapping between the trough displacement and the target phase or time delay. Theoretical analysis shows that, under detector resolution limits, the measurement resolution depends solely on the frequency of extinction point and is independent of weak-value singular amplification or bias-phase modulation, thereby maintaining high sensitivity while avoiding pointer saturation. Experiments demonstrate that the trough-shift scheme achieves significantly better agreement between measured and theoretical sensitivities than biased weak measurement and provides a stable linear response without additional bias-compensation structures, reaching a minimum resolvable phase variation at the 10−7 level. Moreover, the approach intrinsically supports multi-period traceable measurements and exhibits strong robustness against intensity fluctuations and spectral distortions, offering a promising route toward high-sensitivity, large-dynamic-range, and stable weak measurement-based optical sensing.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
We propose a scheme called difference weak measurement, and we illustrate its advantages for measuring a small longitude phase shift in high precision. Compared to the standard interferometry and standard weak measurement schemes, the proposed scheme has a much higher resolution in the presence of various practical imperfections, such as alignment error and light intensity variation error. Moreover, we highlight the advantage of utilizing a complex weak value, where its imaginary part can reduce the harmful effect induced by channel decoherence. Finally, we propose a closed-loop scenario to solve the narrow dynamic range problem that exists in the current weak measurement schemes. The difference weak measurement scheme simultaneously fulfills the requirements of high precision, wide dynamic range, and strong robustness, which makes it a powerfully practical tool for phase-shift measurement and other metrological tasks.
We theoretically propose and experimentally demonstrate a modulated weak measurement scheme that permits a precise estimation of the extended phase shift. By choosing the frequency and the total post-selected light intensity as the input and output meter variables, respectively, a linear weak measurement model is established that is especially applicable to precise phase estimation. By performing a time-delay-dependent modulation strategy based on the feedback modulation of the experimental outcome, both the high phase-sensitivity and measurement precision can be retained. We have achieved a precision at the order of ∼10−5 rad that can be effectively retained with an increase in the measured phase.
Abstract Quantum metrology has emerged as a crucial paradigm for enhancing measurement sensitivity beyond classical limits. While standard weak measurement and static biased phase methods can effectively amplify extremely small signals, they fundamentally suffer from a trade-off between postselection probability and linear response range, leaving them vulnerable to parameter drift. Motivated by realistic experimental applications such as measuring optical birefringence or thickness using a polarization-frequency Sagnac interferometer, we propose an adaptive biased weak measurement (ABWM) scheme that combines the sensitivity enhancement of biased weak measurement with a feedback-assisted adjustment of the bias phase. By dynamically updating the bias phase in response to measurement outcomes, the system can track slow parameter variations and maintain nearoptimal estimation precision. Numerical simulations under technical noise demonstrate reliable convergence from multiple random initial bias phases and show that the proposed adaptive- β strategy achieves more accurate dynamic tracking than standard weak measurement and static biased weak measurement. Our results suggest that ABWM provides a flexible and resource-efficient strategy for high-precision quantum metrology in realistic experimental scenarios.
High-precision surface-roughness estimation plays an important role in many applications. However, the classical estimating methods are limited by shot noise and can only achieve a precision of 0.1 nm with a white-light interferometer. Here, we propose two weak-measurement schemes to estimate surface roughness through a spectrum analysis and intensity analysis. The estimating precision with the spectrum analysis is about ${10}^{\ensuremath{-}5}$ nm by using a currently available spectrometer with a resolution of $\mathrm{\ensuremath{\Delta}}\ensuremath{\lambda}=0.04$ pm and the corresponding sensitivity is better than 0.1 THz/nm. The precision and sensitivity of the light intensity analysis scheme achieved is as high as 0.07 nm and 1/nm, respectively. By introducing a modulated phase, we show that the sensitivity and precision achieved in our schemes can be effectively retained in a wider dynamic range. We further provide the experimental design of a surface profiler based on our schemes. It simultaneously meets the requirements of high precision, high sensitivity, and a wide measurement range, making it a promising practical tool.
We experimentally demonstrate a sub-nanometer optical path difference (OPD) metrology scheme based on biased weak measurement (BWM) with real weak values using a classical coherent light source. By introducing a controlled bias phase in a Mach-Zehnder interferometric configuration, the proposed approach enables enhanced detection of sub-nanometer OPD variations while maintaining compatibility with common optical components and narrowband light sources. We systematically compare the measurement response, sensitivity, and signal-to-noise ratio (SNR) of BWM with those of standard weak measurement (SWM) and conventional interferometric measurement (CM) under identical experimental conditions. Relative to SWM, BWM provides an approximately fourfold enhancement in measurement response within the linear operating range, while achieving a (94 ± 10)-fold signal amplification compared with CM. Furthermore, the measured SNR exhibits an order-of-magnitude improvement over CM under detector-saturation-limited measurement conditions. Experimentally, the BWM scheme achieves a minimum detectable OPD of (5.6 ± 0.36) × 10 −4 nm, obtained from Allan deviation analysis. These results highlight the potential of weak measurement as a practical strategy for high-precision optical path metrology and precision interferometric sensing.