Optical and Quantum Sensing and Precision Metrology II

Novel tests of relativity with optical ion clocks

Christian Sanner

Published Mar 5, 2026• 0 citations
Publisher

Abstract

Optical clocks based on atoms and ions probe relativistic effects with unparalleled sensitivity. By performing clock spectroscopy on a single ytterbium ion in a cryogenic environment we have full quantum control over all internal and external degrees of freedom and expect strongly improved coherence times. This makes it possible to realize novel tests of relativity in a regime where superpositions of proper time emerge.

DOI
10.1117/12.3089860

Related papers

Quantum Signatures of Proper Time in Optical Ion Clocks

Gabriel Sorci, Joshua Foo, Dietrich G. Leibfried +2 more

Optical clocks based on atoms and ions probe relativistic effects with unprecedented sensitivity. They resolve time dilation due to atom motion or different positions in the gravitational potential through frequency shifts. However, all measurements of time dilation so far can be explained effectively as the result of dynamics with respect to a classical proper time parameter. Here we show that atomic clocks can probe effects where a classical description of the proper time dynamics is insufficient as superpositions of proper time emerge. We apply a Hamiltonian formalism to derive time dilation effects in harmonically trapped clock atoms and show how second-order Doppler shifts due to the vacuum energy, squeezing, and quantum corrections to the dynamics arise. We also demonstrate that time-dilation-induced entanglement between motion and clock evolution can become observable in state-of-the-art clocks when the motion of the atoms is strongly squeezed, realizing proper time interferometry. Our results show that experiments with trapped ion clocks are within reach of probing relativistic evolution of clocks for which a quantum description of proper time becomes necessary.

arXiv:2509.09573•Physical Review Letters•Feb 27, 2026•6 citations

Trapping and cooling of single ions for frequency metrology and quantum optics experiments

L. Slodička, M. (Minh Tuan) Pham, A. (Adam) Lešundák +8 more

Single trapped ions trapped in Paul traps correspond to ideal candidates for realization of extremely accurate optical atomic clocks and practical studies of the light–atom interactions and nonlinear mechanical dynamics. These systems benefit from both, the superb isolation of the ion from surrounding environment and excellent control of its external and internal\ndegrees of freedom, at the same time, which makes them exquisite platforms for experimental studies and applications of light matter interaction at its most fundamental level. The exceptional degree of control of single or few ion's state enabled in past decade number of major advancements in the applications from the fields of experimental quantum information\nprocessing and frequency metrology, including recent realization of scalable Shor's\nalgorithm, fractional uncertainties of the frequency measurements close to 10-18 level, or simulations of complex quantum many-body effects. These results, together with the rapid advancements in the production of low-noise segmented micro-traps, promise prompt access to long-desired regimes of quantum optomechanics and further development and applications\nof optical atomic clocks.

•Jan 1, 2016•0 citations

Exploiting phase coherence for improved resolution in optical atomic frequency ratios

Tara M. Fortier

Optical atomic clocks that operate at frequencies up to 100,000 times higher than their microwave counterparts permit better resolutions and accuracies, while also providing more leeway in environmental control for out of lab applications. Many of the precision applications of these clocks, including relativistic geodesy and tests of fundamental physics rely on the intercomparison of at least two optical clocks. Relative comparisons that include single ion clocks, however, can require close to one month of continuous averaging to achieve measurement instabilities near 1 part in 1018. The long averaging times result from limits imposed on the quantum project noise as a result of signal detection from a single ion, as well as atom probe time limitations due to laser-atom decoherence. In this talk I will describe how the phase coherent properties of an optical frequency comb can be used to enable correlated and synchronous measurement of atomic clocks as a means to improve their relative measurement instability by close to a factor of 10, and nearly 100 times speed up in averaging time over conventional measurement techniques.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•47 citations

Entanglement-Enhanced Optical Ion Clock

Kai Dietze, Lennart Pelzer, Ludwig Krinner +11 more

Entangled states hold the promise of improving the precision and accuracy of quantum sensors. We experimentally demonstrate that spectroscopy of an optical clock transition using entangled states can outperform its classical counterpart. Two ^{40}Ca^{+} ions are entangled in a quantum state with vanishing first-order magnetic field sensitivity, extending the coherence time of the atoms and enabling near-lifetime-limited probe times of up to 550 ms. In our protocol, entangled ions reach the same instability as uncorrelated ions, but at half the probe time, enabling faster cycle times of the clock. We run two entangled ^{40}Ca^{+} ions as an optical clock and compare its frequency instability with a ^{87}Sr lattice clock. The instability of the entangled ion clock is below a clock operated with classically correlated states for all probe times. We observe instabilities below the theoretically expected quantum projection noise limit of two uncorrelated ions for interrogation times below 100 ms. The lowest fractional frequency instability of 7×10^{-16}/sqrt[τ/1 s] is reached for 250 ms probe time, limited by residual phase noise of the probe laser. This represents the lowest instability reported to date for a ^{40}Ca^{+} ion clock.

arXiv:2506.11810•Physical Review Letters•Jan 2, 2026•9 citations

Frequency standards based on ultracold atoms in tests of general relativity, navigation and gravimetry

Ksenia Yu. Khabarova, K. S. Kudeyarov, N. Kolachevsky

Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 10 18 . The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for 'dark matter') as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues.

Quantum Electronics•May 9, 2017•0 citations
Optical clocks based on atoms and ions probe relativistic effects with unparalleled sensitivity. By performing clock spectroscopy on a single ytterbium ion in a cryogenic environment we have full quantum control over all internal and external degrees of freedom and expect strongly improved coherence times. This makes it possible to realize novel tests of relativity in a regime where superpositions of proper time emerge.
Optical clocks based on atoms and ions probe relativistic effects with unprecedented sensitivity. They resolve time dilation due to atom motion or different positions in the gravitational potential through frequency shifts. However, all measurements of time dilation so far can be explained effectively as the result of dynamics with respect to a classical proper time parameter. Here we show that atomic clocks can probe effects where a classical description of the proper time dynamics is insufficient as superpositions of proper time emerge. We apply a Hamiltonian formalism to derive time dilation effects in harmonically trapped clock atoms and show how second-order Doppler shifts due to the vacuum energy, squeezing, and quantum corrections to the dynamics arise. We also demonstrate that time-dilation-induced entanglement between motion and clock evolution can become observable in state-of-the-art clocks when the motion of the atoms is strongly squeezed, realizing proper time interferometry. Our results show that experiments with trapped ion clocks are within reach of probing relativistic evolution of clocks for which a quantum description of proper time becomes necessary.
Single trapped ions trapped in Paul traps correspond to ideal candidates for realization of extremely accurate optical atomic clocks and practical studies of the light–atom interactions and nonlinear mechanical dynamics. These systems benefit from both, the superb isolation of the ion from surrounding environment and excellent control of its external and internal\ndegrees of freedom, at the same time, which makes them exquisite platforms for experimental studies and applications of light matter interaction at its most fundamental level. The exceptional degree of control of single or few ion's state enabled in past decade number of major advancements in the applications from the fields of experimental quantum information\nprocessing and frequency metrology, including recent realization of scalable Shor's\nalgorithm, fractional uncertainties of the frequency measurements close to 10-18 level, or simulations of complex quantum many-body effects. These results, together with the rapid advancements in the production of low-noise segmented micro-traps, promise prompt access to long-desired regimes of quantum optomechanics and further development and applications\nof optical atomic clocks.
Optical atomic clocks that operate at frequencies up to 100,000 times higher than their microwave counterparts permit better resolutions and accuracies, while also providing more leeway in environmental control for out of lab applications. Many of the precision applications of these clocks, including relativistic geodesy and tests of fundamental physics rely on the intercomparison of at least two optical clocks. Relative comparisons that include single ion clocks, however, can require close to one month of continuous averaging to achieve measurement instabilities near 1 part in 1018. The long averaging times result from limits imposed on the quantum project noise as a result of signal detection from a single ion, as well as atom probe time limitations due to laser-atom decoherence. In this talk I will describe how the phase coherent properties of an optical frequency comb can be used to enable correlated and synchronous measurement of atomic clocks as a means to improve their relative measurement instability by close to a factor of 10, and nearly 100 times speed up in averaging time over conventional measurement techniques.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
Entangled states hold the promise of improving the precision and accuracy of quantum sensors. We experimentally demonstrate that spectroscopy of an optical clock transition using entangled states can outperform its classical counterpart. Two ^{40}Ca^{+} ions are entangled in a quantum state with vanishing first-order magnetic field sensitivity, extending the coherence time of the atoms and enabling near-lifetime-limited probe times of up to 550 ms. In our protocol, entangled ions reach the same instability as uncorrelated ions, but at half the probe time, enabling faster cycle times of the clock. We run two entangled ^{40}Ca^{+} ions as an optical clock and compare its frequency instability with a ^{87}Sr lattice clock. The instability of the entangled ion clock is below a clock operated with classically correlated states for all probe times. We observe instabilities below the theoretically expected quantum projection noise limit of two uncorrelated ions for interrogation times below 100 ms. The lowest fractional frequency instability of 7×10^{-16}/sqrt[τ/1 s] is reached for 250 ms probe time, limited by residual phase noise of the probe laser. This represents the lowest instability reported to date for a ^{40}Ca^{+} ion clock.
Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 10 18 . The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for 'dark matter') as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues.