Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Sympathetic-laser-cooling ion microwave frequency standard with accuracy and stability at 10 − 15 level

Y.Z. Zheng, S. N. Miao, Yiting Chen, Wenxin Shi, Jianwei Zhang, Lijun Wang

Published Mar 3, 2026• 0 citations
Publisher
DOI
10.1103/1fp9-738h

Related papers

Laser-cooled ytterbium-ion microwave frequency standard

S. Mulholland, H. A. Klein, G. P. Barwood +6 more

arXiv:1811.06421•Applied Physics B•Oct 5, 2019•26 citations

High-Performance Microwave Frequency Standard Based on Sympathetically Cooled Ions

H. R. Qin, S. N. Miao, J. Z. Han +4 more

The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled ${}^{40}{\mathrm{Ca}}^{+}$ as coolant ions, ${}^{113}{\mathrm{Cd}}^{+}$ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.

arXiv:2204.05040•Physical Review Applied•Aug 8, 2022•15 citations

Laser-cooled Cs-fountain frequency standard

Kurt Gibble, Steven Chu

Quantum Electronics and Laser Science Conference•May 2, 1993•0 citations

Sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for Microwave Ion Clocks

J. Z. Han, H. R. Qin, Limin Guo +6 more

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured at $90(10)$ mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of $2\times10^{-17}$. Up to $4.2\times10^5$ Cd$^+$ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still $10^5$ Cd$^+$ ions present, indicating that this Ca$^+$--Cd$^+$ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca$^+$ lasers and fluorescence, which was carefully estimated to an accuracy of $5.4(0.5)\times10^{-17}$ using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.

arXiv:2002.04228•Feb 11, 2020•0 citations

Progress on Ion Microwave Frequency Standards at Tsinghua University

H. R. Qin, Y.Z. Zheng, L. J. Wang +6 more

SummaryThe ion microwave frequency standard is a candidate for the next generation of practical microwave frequency standards, which has a very wide application potential. Tsinghua University has continuously been working on the research and development of ion microwave frequency standards. A demonstration experiment of two laser-cooled cadmium ion microwave clocks with zero dead time shows a short-term stability of τ-0.95averaging. Besides, a microwave frequency standard based on cadmium ions sympathetically cooled by ytterbium ions has been realized, and the clock signal has been obtained. In addition, two new laser-cooled ytterbium ion microwave clocks are also being built.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 15, 2023•0 citations

A ^199Hg^+ Trapped Ion Microwave Frequency Standard

Dana J. Berkeland, J.D. Miller, Wayne M. Itano +2 more

APS•May 1, 1998•0 citations
The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled 40Ca+{}^{40}{\mathrm{Ca}}^{+}40Ca+ as coolant ions, 113Cd+{}^{113}{\mathrm{Cd}}^{+}113Cd+ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.
Sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for Microwave Ion Clocks
We report sympathetic cooling of 113^{113}113Cd+^++ by laser-cooled 40^{40}40Ca+^++ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of 113^{113}113Cd+^++ ions was achieved. The temperature of these ions was measured at 90(10)90(10)90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of 2×10−172\times10^{-17}2×10−17. Up to 4.2×1054.2\times10^54.2×105 Cd+^++ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still 10510^5105 Cd+^++ ions present, indicating that this Ca+^++--Cd+^++ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca+^++ lasers and fluorescence, which was carefully estimated to an accuracy of 5.4(0.5)×10−175.4(0.5)\times10^{-17}5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
SummaryThe ion microwave frequency standard is a candidate for the next generation of practical microwave frequency standards, which has a very wide application potential. Tsinghua University has continuously been working on the research and development of ion microwave frequency standards. A demonstration experiment of two laser-cooled cadmium ion microwave clocks with zero dead time shows a short-term stability of τ-0.95averaging. Besides, a microwave frequency standard based on cadmium ions sympathetically cooled by ytterbium ions has been realized, and the clock signal has been obtained. In addition, two new laser-cooled ytterbium ion microwave clocks are also being built.