The ion microwave frequency standard is a candidate for the next generation of microwave frequency standard with the potential for very wide applications. The Dick effect and second-order Doppler frequency shift (SODFS) limit the performance of ion microwave frequency standards. The introduction of sympathetic cooling technology can suppress the Dick effect and SODFS and improve the stability and accuracy of the frequency standard. However, the sympathetically cooled ion microwave frequency standard has seldom been studied before. This paper reports a high-performance sympathetically cooled ion microwave frequency standard in a Paul trap. Using laser-cooled
40Ca+ as coolant ions,
113Cd+ ion crystal is cooled to below 100 mK and has a coherence lifetime of over 40 s. The short-term frequency stability reached $3.48\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/{\ensuremath{\tau}}^{1/2}$, which is comparable to that of the mercury ion frequency standard. Its uncertainty is $1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$, which is better than that of directly laser-cooled cadmium ion frequency standard.
We report sympathetic cooling of
113Cd
+ by laser-cooled
40Ca
+ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of
113Cd
+ ions was achieved. The temperature of these ions was measured at
90(10) mK, and the corresponding uncertainty arising from the second-order Doppler shifts was estimated to a level of
2×10−17. Up to
4.2×105 Cd
+ ions were confined in the trap, and the confinement time constant was measured to be 84 hours. After three hours of confinement, there were still
105 Cd
+ ions present, indicating that this Ca
+--Cd
+ dual ion system is surprisingly stable. The ac Stark shift was induced by the Ca
+ lasers and fluorescence, which was carefully estimated to an accuracy of
5.4(0.5)×10−17 using a high-accuracy \textit{ab initio} approach. The Dick-effect-limited Allan deviation was also deduced because deadtimes were shorter. These results indicate that a microwave clock based on this sympathetic cooling scheme holds promise in providing ultra-high frequency accuracy and stability.
SummaryThe ion microwave frequency standard is a candidate for the next generation of practical microwave frequency standards, which has a very wide application potential. Tsinghua University has continuously been working on the research and development of ion microwave frequency standards. A demonstration experiment of two laser-cooled cadmium ion microwave clocks with zero dead time shows a short-term stability of τ-0.95averaging. Besides, a microwave frequency standard based on cadmium ions sympathetically cooled by ytterbium ions has been realized, and the clock signal has been obtained. In addition, two new laser-cooled ytterbium ion microwave clocks are also being built.