Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement

Suppression of heading error induced by vector light shift in a CPT atomic magnetometer using a double-pass configuration

Chen Wang, Pengcheng Du, Feifan Yang, Gang Liu

Published Feb 23, 2026• 0 citations
Publisher
DOI
10.1016/j.measurement.2026.120938

Related papers

Suppression of light shift in dual-pump three-axis vector atomic magnetometers

Lin Li, Junjian Tang, Binbin Zhao +1 more

Optics & Laser Technology•Aug 7, 2023•3 citations

Measurement and suppression of tensor light shift for nonlinear magneto-optical rotating atomic magnetometers

Mengnan Tian, Liwei Jiang, Yanchao Chai +5 more

Sensors and Actuators A Physical•Apr 21, 2025•2 citations

Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers

Yuhao Wang, Ziqi Yuan, Shudong Lin +4 more

Measurement•Oct 15, 2025•2 citations

Suppression of light shifts in pulsed CPT clocks using a combined error signal to stabilize the local oscillator frequency

Отдел лазерной физики и технологий Новосибирского государственного университета, Новосибирск, Россия, Ivan Gromov, Polina Kozmina

Международная научно-практическая конференция «Актуальные проблемы науки и образования в условиях современных вызовов»•Jan 1, 2024•0 citations

Nuclear Zeeman Effect on Heading Errors and the Suppression in Atomic Magnetometers

Chang, Yue, Guo, Yu-Hao, Shuang-Ai Wan +1 more

The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to the RF driving magnetic field. Thus, one can design the configuration of the magnetometer and make it work in the smaller-heading-error regime. To suppress the heading error, our studies suggest to sum up the output precession frequencies from atomic cells pumped by two lasers with opposite helicities and probed by lasers propagating in orthogonal directions (one parallel and another perpendicular to the RF field), instead of utilizing probe lasers propagating in the same directions. Due to the nuclear Zeeman effect, the average precession frequencies in the latter case can have a non-negligible angular dependence, while in the former case the nuclear-Zeeman-effect induced heading error can be largely compensated and the residue is within 1Hz. Furthermore, for practical use, we propose to simply utilize a small magnetic field parallel/antiparallel to the pump laser. By tuning the magnitude of this auxiliary field, the heading error can be flattened around different angles, which can improve the accuracy when the magnetometer works around a certain orientation angle.

arXiv:2102.03037•Jan 1, 2021•2 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•7 citations
The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to the RF driving magnetic field. Thus, one can design the configuration of the magnetometer and make it work in the smaller-heading-error regime. To suppress the heading error, our studies suggest to sum up the output precession frequencies from atomic cells pumped by two lasers with opposite helicities and probed by lasers propagating in orthogonal directions (one parallel and another perpendicular to the RF field), instead of utilizing probe lasers propagating in the same directions. Due to the nuclear Zeeman effect, the average precession frequencies in the latter case can have a non-negligible angular dependence, while in the former case the nuclear-Zeeman-effect induced heading error can be largely compensated and the residue is within 1Hz. Furthermore, for practical use, we propose to simply utilize a small magnetic field parallel/antiparallel to the pump laser. By tuning the magnitude of this auxiliary field, the heading error can be flattened around different angles, which can improve the accuracy when the magnetometer works around a certain orientation angle.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.