Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

A field-deployable compact gravimeter based on a grating magneto-optical trap with μGal-level long-term stability

Sangwon Seo, Hyun-Gue Hong, Jae-Hoon Lee, Sang Eon Park, Taeg Yong Kwon, Sanglok Lee, Jeongju Choi, Meungho Seo, Jongcheol Park, Sang-Bum Lee

Published Feb 9, 2026• 3 citations
Publisher

Abstract

We present a compact quantum gravimeter based on a grating magneto-optical trap using 87Rb atoms that achieves μGal-level long-term stability without passive vibration isolation. The sensor head integrates magnetic shielding, an ion pump, optical components, and a classical seismometer within a total volume of less than 75L. The gravimeter achieves a sensitivity of 270 μGal/Hz and a stability of 5 μGal at a 1-h average with the long-term gravity record in good agreement with the theoretical tidal model. These results demonstrate a field-deployable platform for portable and chip-integrable quantum gravimetry.

DOI
10.1063/5.0307253

Related papers

A Compact Cold Atom Gravimeter Utilizing a Grating Magneto Optical Trap

Sangwon Seo, Jae Hoon Lee, Sang-Bum Lee +6 more

For a wide range of applications quantum gravimeters demands miniaturizing the physics package of a sensor which is, in laboratory environments, as big as a few meters. One approach to this end is adopting unconventional magneto-optical traps (MOT) such as pyramid MOTs [1] and grating MOTs (gMOT) [2]. In particular, grating MOT has opened an interesting opportunity to integrate complex experimental apparatuses into a planar chip [3], [4].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•0 citations

Mobile quantum gravimeter with a novel pyramidal magneto-optical trap

Xiaojing Wu, Storm Weiner, Zachary Pagel +2 more

We demonstrate a mobile quantum gravimeter measuring tidal gravity variations in the laboratory and surveying gravity in the field. With simplicity and sensitivity, our instrument paves the way for bringing quantum sensors to field applications.

Conference on Lasers and Electro-Optics•Jan 1, 2020•4 citations

Design and construction of a transportable quantum gravimeter and realization of an atom-chip magnetic trap

Maral Sahelgozin

The quantum gravimeter QG-1 is designed to perform local gravity measurements in field with residual uncertainties surpassing state-of-the-art absolute gravimeters. It will use delta-kick collimated Bose-Einstein condensates (BEC) of 87 Rb atoms as the source for matter-wave interferometry and aims for an uncertainty level below 3 nm/s 2 with a repetition rate of 0.5 Hz. In the frame of this thesis, the atom-chip source has been set up and characterized. In order to meet the requirements for transportability, the apparatus needs to be compact and robust. Additionally, a high BEC flux is desired for the targeted statistical uncertainty. To meet these requirements a double magneto-optical trap (MOT) configuration based on a 3-layer atom chip has been implemented. Furthermore, a compact high power fiber-based laser system has been developed to provide the light for atomic manipulation. To power and control this laser system and generate the magnetic fields necessary to trap atoms, a miniaturized electronic system with low power consumption has been utilized and characterized. The steps towards trapping the atoms inside a magnetic trap on which the evaporation will be implemented have been realized and optimized. A two-dimensional MOT has been employed and an optimized atomic beam flux of 2.2 × 10 9 atoms/s with a mean longitudinal velocity of 17.2 m/s and a narrow longitudinal velocity distribution of 2.2 m/s has been used to load a 3D-chip MOT. The resulting 3D-MOT has been characterized and a loading rate of 8.1×10 8 atoms/s has been attained. After loading for 300 ms, 2.4×10 8 atoms are trapped in the 3D-MOT. Applying a subsequent compressed MOT stage, the cloud density has been increased by a factor of 10. This denser atomic ensemble with 2.9 × 10 10 atoms/cm 3 has been further cooled in a polarization gradient cooling (PGC) stage to 5.6 μK in order to increase the mode match with the subsequent magnetic trap. In the initial large volume magnetic trap generated by the wire structures on the mesoscopic and the base layers of the atom-chip assembly, 3.6 × 10 7 atoms have been captured. This trap features a temperature of 44.3 μK, a trapping frequency of 9.1 Hz in its weak confining axis and a phase-space density of 4.5 × 10 −7 . The process of transferring the atoms into the final magnetic trap with higher trapping frequency for an efficient BEC evaporation, which is formed by the wire structures on the base and science chip has been tested. With this, all the necessary functionalities of a high-flux BEC source setup have been demonstrated.

•Jan 1, 2019•3 citations

Grating chips for quantum technologies

J. P. McGilligan, Paul F. Griffin, Rachel Elvin +3 more

Rb atoms to 3 μK in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.

arXiv:1702.04150•Scientific Reports•Mar 17, 2017•87 citations

Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter

Zhong-Kun Hu, Bu-Liang Sun, Xiao‐Chun Duan +5 more

We present an ultrahigh-sensitivity gravimeter based on an ${}^{87}$Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ $\text{m}/{\text{s}}^{2}$) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.

Physical Review A•Oct 8, 2013•414 citations

Compact Cold-Atom Platform Based on Optical Grating and Planar Coil Chips

Chang-Jiang Huang, Lei Xu, Liang Chen +4 more

Abstract We present a compact cold atom platform where an optical grating chip and planar coil chip are placed inside a compact vacuum chamber to create a magneto-optical trap. This approach significantly reduces the system volume to about 20 × 20 × 20 cm3 compared to conventional vacuum systems and offers greater flexibility in accessing the trapped atoms. We demonstrate the trapping of 3 × 105 cold rubidium atoms at a temperature of 100 μK in a vacuum pressure below 10−7 mbar. The simplified optical geometry, low power consumption, and high degree of integration make this a promising platform for portable and versatile cold-atom devices in quantum sensing, timing, and information processing.

Chinese Physics Letters•May 6, 2025•2 citations
We present a compact quantum gravimeter based on a grating magneto-optical trap using 87Rb atoms that achieves μGal-level long-term stability without passive vibration isolation. The sensor head integrates magnetic shielding, an ion pump, optical components, and a classical seismometer within a total volume of less than 75L. The gravimeter achieves a sensitivity of 270 μGal/Hz and a stability of 5 μGal at a 1-h average with the long-term gravity record in good agreement with the theoretical tidal model. These results demonstrate a field-deployable platform for portable and chip-integrable quantum gravimetry.
The quantum gravimeter QG-1 is designed to perform local gravity measurements in field with residual uncertainties surpassing state-of-the-art absolute gravimeters. It will use delta-kick collimated Bose-Einstein condensates (BEC) of 87 Rb atoms as the source for matter-wave interferometry and aims for an uncertainty level below 3 nm/s 2 with a repetition rate of 0.5 Hz. In the frame of this thesis, the atom-chip source has been set up and characterized. In order to meet the requirements for transportability, the apparatus needs to be compact and robust. Additionally, a high BEC flux is desired for the targeted statistical uncertainty. To meet these requirements a double magneto-optical trap (MOT) configuration based on a 3-layer atom chip has been implemented. Furthermore, a compact high power fiber-based laser system has been developed to provide the light for atomic manipulation. To power and control this laser system and generate the magnetic fields necessary to trap atoms, a miniaturized electronic system with low power consumption has been utilized and characterized. The steps towards trapping the atoms inside a magnetic trap on which the evaporation will be implemented have been realized and optimized. A two-dimensional MOT has been employed and an optimized atomic beam flux of 2.2 × 10 9 atoms/s with a mean longitudinal velocity of 17.2 m/s and a narrow longitudinal velocity distribution of 2.2 m/s has been used to load a 3D-chip MOT. The resulting 3D-MOT has been characterized and a loading rate of 8.1×10 8 atoms/s has been attained. After loading for 300 ms, 2.4×10 8 atoms are trapped in the 3D-MOT. Applying a subsequent compressed MOT stage, the cloud density has been increased by a factor of 10. This denser atomic ensemble with 2.9 × 10 10 atoms/cm 3 has been further cooled in a polarization gradient cooling (PGC) stage to 5.6 μK in order to increase the mode match with the subsequent magnetic trap. In the initial large volume magnetic trap generated by the wire structures on the mesoscopic and the base layers of the atom-chip assembly, 3.6 × 10 7 atoms have been captured. This trap features a temperature of 44.3 μK, a trapping frequency of 9.1 Hz in its weak confining axis and a phase-space density of 4.5 × 10 −7 . The process of transferring the atoms into the final magnetic trap with higher trapping frequency for an efficient BEC evaporation, which is formed by the wire structures on the base and science chip has been tested. With this, all the necessary functionalities of a high-flux BEC source setup have been demonstrated.
We present an ultrahigh-sensitivity gravimeter based on an 87{}^{87}87Rb atom interferometer using stimulated Raman transitions. Compared with our previous work, a two-dimensional magneto-optical trap is added in the new gravimeter to increase the atom number and improve the detection signal-to-noise ratio, and a better optical phase-locked loop system is used to reduce the phase noise of Raman beams. Benefiting from these efforts and the excellent performance of the active vibration isolator, a short-term sensitivity of about 4.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$ ($1\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ m/s2\text{m}/{\text{s}}^{2}m/s2) is reached, which improves the sensitivity by a factor of 2 compared with the former best reported value. By a modulation experiment, we further indicate that the residual vibration noise contribution is about 1.2 $\ensuremath{\mu}\text{Gal}/\sqrt{\text{Hz}}$, which implies a possible improvement over the present absolute gravity measurement level by about one order of magnitude. Moreover, we demonstrate a calibration experiment to directly evaluate the sub-$\ensuremath{\mu}$Gal resolution of our gravimeter.
Abstract We present a compact cold atom platform where an optical grating chip and planar coil chip are placed inside a compact vacuum chamber to create a magneto-optical trap. This approach significantly reduces the system volume to about 20 × 20 × 20 cm3 compared to conventional vacuum systems and offers greater flexibility in accessing the trapped atoms. We demonstrate the trapping of 3 × 105 cold rubidium atoms at a temperature of 100 μK in a vacuum pressure below 10−7 mbar. The simplified optical geometry, low power consumption, and high degree of integration make this a promising platform for portable and versatile cold-atom devices in quantum sensing, timing, and information processing.