This thesis presents an in depth look into the design and construction of a series of new co-magnetometry experiments. Work to design a high performance magnetic shield that minimises magnetic shield noise whilst maintaining a larger internal volume is detailed. A high-performance magnetic coil assembly that optimally fits within a cylindrical environment is designed and implemented. Preliminary work to characterise one of the co-magnetometry systems utilising novel high pressure 87Rb - 21Ne atomic vapour cells is conducted. This presented possible multiple Lar-mor precession resonances within the vapour cell, representing new physics. The creation of separated regions within the vapour cell due to high diffusion times is hypothesised and offered for further investigation.
This thesis presents an in depth look into the design and construction of a series of new co-magnetometry experiments. Work to design a high performance magnetic shield that minimises magnetic shield noise whilst maintaining a larger internal volume is detailed. A high-performance magnetic coil assembly that optimally fits within a cylindrical environment is designed and implemented. Preliminary work to characterise one of the co-magnetometry systems utilising novel high pressure 87Rb - 21Ne atomic vapour cells is conducted. This presented possible multiple Lar-mor precession resonances within the vapour cell, representing new physics. The creation of separated regions within the vapour cell due to high diffusion times is hypothesised and offered for further investigation.
This thesis presents advancements in radio-frequency atomic magnetometry utilising cold atoms as sensors. While cold atom magnetometers demonstrate lower absolute sensitivity compared to conventional vapour cell systems due to reduced atom numbers, they offer exceptional spatial resolution at the micrometre scale. The experimental apparatus features a cold atom production system capable of reaching quantum degeneracy through a refined cooling sequence that involves optical molasses, magnetic trapping and evaporation, and optical evaporative cooling in the dipole trap, culminating in a 87Rb Bose-Einstein condensate. This work details the development and characterisation of magnetometer set-ups with progressively enhanced performance. The first magnetometer utilised atoms in the optical molasses phase as a sensor, achieving an AC sensitivity of 330 pT/√Hz with approximately 108 atoms at 20 μK. Comprehensive magnetometry optimisation methods were developed to enhance sensitivity. Following laboratory interruptions due to the COVID-19 pandemic, system rebuilding incorporated significant upgrades, including a new probe laser and gradient compensation systems. The improved magnetometer prototype achieved a substantially enhanced sensitivity of 0.72±0.33 pT/√Hz, approaching the fundamental sensitivity limit of the system. Using atoms in the magnetic trap as a sensor, a sensitivity of 1.85 pT/√Hz was demonstrated. The system was verified to be photon-shot noise limited. Investigations into a double-pass probe configuration showed that, while the measured sensitivity was similar to that of the single-pass (4.3 pT/√Hz compared to 3.1 pT/√Hz at a probe power of 6.4 μW measured at the detector), the rotation angle increased by a factor of 2.2, with significantly reduced noise levels. These findings suggest that multi-pass strategies hold promise for enhanced performance in future implementations. In addition, the first signal detection from a BEC magnetometer, achieving 4.5 nT/√Hz with only 95,000 atoms at 35 nK was demonstrated.
The development of an experimental apparatus to produce Bose-Einstein condensates (BECs) of ⁸⁷Rb atoms and their application to magnetometry are discussed. Optical detection of atomic Larmor precession is a widely explored method for high-sensitivity measurements of magnetic fields. In this context, short laser/atom interaction time, atomic thermal diffusion and decoherence effects are among the main limitations. In this thesis, we overcome such problems by using spin-polarised ⁸⁷Rb ultra-cold atoms as the sensing element. After the atoms are polarised, a resonant pulse of radio-frequency excites Larmor precession, which is sensitive to external magnetic fields. By measuring the perturbations of the radio-frequency induced spin precession, information on the magnetic fields of interest. This is achieved by monitoring the polarisation plane’s rotation of a linearly polarised resonant laser probe. In the first part of this thesis, the building and optimisation of a laser-cooling set up to obtain a BEC in a hybrid trap is reported. In order to achieve the Phase Space Density (PSD) required for BEC, several different stages of trapping and cooling are necessary. Each phase has been implemented and optimised. The first step consists in the magneto-optical trap (MOT). Here a velocity dependent damping force and a spatially dependent confining force give the largest changes in PSD. Then atoms are loaded into a hybrid trap obtained by overlapping a quadrupole magnetic potential and a far detuned optical crossed dipole trap. The final stage for the condensation consists of forced evaporative cooling, both via magnetic and optical evaporation. In the second part of the thesis, a general overview of the principles of optical atomic magnetometry is provided and the advantages of using ultra-cold atoms with respect to conventional thermal vapours are discussed. The implementation, operation and a preliminary characterisation of the ultra-cold atom magnetometer are described along with the preliminary results collected. Finally, a plan for future improvements of its sensitivity is presented.
This thesis describes the design, construction and optimisation of a new apparatus to produce Bose-Einstein condensates (BECs) of 87Rb atoms. The main aim in building this system was to include a high resolution imaging system capable of resolving single atoms. Optical access for the imaging system was created by including a stage of atom transport in which the atoms are magnetically transferred ~50 cm from a magneto-optical trap (MOT), where they are initially collected, to a glass science cell where experiments are carried out and imaging takes place. Two magnetic transport schemes have been demonstrated, based on approaches first used in other laboratories. First, a scheme in which the atoms are transferred in a moving pair of magnetic trapping coils. Second, a hybrid scheme where the atoms are translated part of the distance in the moving coils, and the rest of the way by switching the current in a chain of fixed coils. This second scheme was designed to allow optical access for a high numerical aperture microscope objective to be placed immediately next to the science cell for high resolution imaging.The atoms were first collected in a large pyramid MOT which can be loaded with 3 × 10^9 atoms in a time of 20 s. Around half of these atoms – those in the |F = 1, mF = −1> magnetic substate – were then magnetically trapped prior to transport. The typical fraction of the trapped atoms transferred to the science cell was ~30% and ~18% for the moving coils and hybrid schemes respectively.Evaporative cooling was carried out on the atom cloud following transport with the moving coils and loading into a time-orbiting potential trap. The optimised cooling sequence lasted for 28 s and consistently produced a pure condensate with 5 × 10^5 atoms. A BEC has also been produced by evaporative cooling following hybrid transport. The next experimental steps will be to optimise the hybrid transfer approach further and install the high resolution imaging system.The system is well-placed to continue an ongoing series of experiments in which ultracold atoms are trapped in RF-dressed potentials. These potentials will be used to study low-dimensional quantum gases as well as in experiments where small atom number BECs are rapidly rotated to enter the fractional quantum Hall regime.
Spinor Bose-Einstein condensates (BECs) are multi-component superfluids with magnetic interactions, formed from dilute gases of atoms in the Zeeman sublevels mF of a single hyperfine ground state F. Spinor BECs are inherently magnetic quantum objects, and exhibit a multitude of features such as spin domains, magnon excitations, and distinct magnetic phases. At the heart of the magnetic nature of a spinor BEC is the spin-dependent collisional interaction c, which determines the overall magnetic behaviour of the superfluid. In conjunction with the quadratic Zeeman shift q, the magnitude and sign of c give rise to an intricate magnetic phase diagram. The magnetic phase of a spinor BEC is tunable, and c and q are the knobs. In addition to realising quantum simulators of magnetism, spinor BECs are also precise magnetic sensors. Atomic magnetometry measures the Larmor precession frequency of atoms, which is proportional to the magnetic field strength. The sensitivity of an atomic magnetometer is principally dependent on the duration of the measurement (interrogation time) and number of atoms participating in the measurement. BECs are highly suitable as atomic magnetometers, allowing for long interrogation times and high atomic density, with microscopic sensor volumes. The latter is an important consideration, as measurement of small magnetic sources demand equally microscopic sensors. Established forms of magnetometry (such as warm vapour magnetometers) use large sensing volumes and are not trivially miniaturised. The exquisite sensitivity of a spinor BEC to magnetic fields becomes a liability when one studies low energy (~ 1 Hz) spinor physics over long evolution times (100 ms) in a typical laboratory environment. To first order, the spin-collisional interaction is independent of the magnetic field. However, spatially inhomogeneous magnetic fields are problematic, exerting mechanical forces on the magnetically sensitive spin components, suppressing spin collisions and possibly introducing relaxation mechanisms that confound the observation of intrinsic equilibration. Precise characterisation of magnetic field gradients and their cancellation is thus of paramount importance. In this thesis, the interaction of a spinor BEC with its environment is studied. The construction, operation and optimisation of a BEC machine is described in detail, as well as the quantum state preparation and control techniques used. Spin-mixing collisions were studied by observing population oscillations, the characteristic hallmark of such coherent phenomena. The observed population dynamics showed strong evidence of the deleterious effects of magnetic field gradients. A series of experiments were performed using spin-echo pulse sequences to decouple the evolving spinor condensate from the inhomogeneous magnetic environment with encouraging results, but which posed further questions. The fidelity of spin-echo pulses in the strong radiative coupling regime was also studied. Spinor condensates were then employed as sensitive magnetometers to characterise the magnetic landscape they inhabit. A new method of measuring magnetic field gradients was developed, using a pair of spinor BECs separated in space that are simultaneously addressed by a Ramsey interferometry sequence. Combined with a re-orientable magnetic bias field, the resulting gradiometer was used to measure the magnetic field gradient tensor in vacuo. This scheme can be extended to realise a high-precision vector co-magnetometer, with spatiotemporal sensitivity comparable to established forms of magnetometry. Vector light shifts (VLSs) are optically-induced energy shifts that result in effective magnetic fields, which in our case originate from the laser beams used to trap the atoms. The VLS vanishes for purely linearly polarised light, which is experimentally difficult to obtain in vacuo. Small elliptical polarisation imperfections originating from birefringent optics and the glass vacuum cell result in a non-zero shift that contaminates magnetometry measurements. The VLS is spatially varying due to the intensity gradient of the trapping light. Due to gravitational sag of the trapping potential, the spatial variation of the VLS is accentuated, resulting in an effective magnetic field gradient that contributes to dephasing and component separation. The simultaneous Ramsey interferometry experiments are then adapted to measure the VLS-induced Zeeman shift and diagnose its elimination. Up to 99.96% of the VLS is eliminated using this method, and extensions to the technique are described.
This thesis presents a study on the realisation of a usable rubidium atomic beam inside a sealed vapour cell. A velocity selective optical pumping scheme was implemented to enable the detection of atoms of a particular velocity class travelling between two separated laser beams. This represents a new spectroscopic technique, the usefulness of which has been demonstrated through its applications. In the present work, the vapour cell atomic beam has been used to measure Larmor precession of polarised atoms in a magnetic field and one-dimensional laser cooling.
The field of magnetometry has played a pivotal role in developing our understanding of the world around us, by providing a wealth of unique information via non-invasive magnetic measurements. In many applications the characteristics of magnetic fields — their strength and temporal dependence, for example — constitute a unique fingerprint of their source, and provide a window into both their origin and any underlying physical processes that produced them. The invention of the laser, and recent advancements in anti-relaxation coatings for vapour cells, has revolutionised the field of magnetometry and given rise to a myriad of optical magnetometers which demonstrate exquisite sensitivity. This has seen a movement away from traditional cryogenic magnetometry techniques — which utilise superconducting quantum interference devices — and has ushered in a slew of optical techniques which offer a whole host of benefits such as room-temperature operability, intrinsic accuracy, and portability. Applications which were previously inaccessible due to demanding requirements such as high sensitivity at ambient temperatures, are now permissible using these newly developed optical techniques. This thesis details the development of an ultrastable optical magnetometer based on nonlinear magneto-optical rotation in rubidium vapour, that has been optimised for high sensitivity over long timescales. Additionally, a novel measurement technique — which relies on tracking the instantaneous phase of atomic spin precession — has been developed and demonstrated, resulting in significant improvements to both the amplitude and frequency response of the device when compared to conventional measurement techniques described in the literature. Significant attention is paid to technical and fundamental noise sources, which must be minimised in order to achieve high performance — especially over long timescales. The latter chapters discuss the development of the magnetometer into a sensitive and reliable system, capable of measuring extremely small magnetic-field fluctuations, and transient fields with arbitrarily complex temporal dependence. The capability of the device to measure minute field fluctuations, as well as rapid transient disturbances, may find use in real-world applications such as geophysical exploration, medical diagnostics and imaging, and magnetic anomaly detection. Furthermore, any fundamental physics applications which demand accurate and precise measurements of magnetic fields may find application of this device — and the novel measurement techniques developed within this thesis—extremely beneficial.