Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The European Physical Journal Plus

Optimizing one-qubit refrigerators in the strong-coupling regime

J. J. Fernández

Published Feb 3, 2026• 0 citations
Publisher

Abstract

Abstract Real refrigerators operate in finite time, deviating from classical thermodynamics, which predicts zero cooling power at Carnot efficiency. Finite-time thermodynamics (FTT) addresses this by incorporating realistic constraints, but quantum extensions often rely on the weak-coupling approximation. This approximation fails in systems—such as superconducting circuits or nanomechanical resonators—where qubit-bath interactions are strong. To overcome this, we study a one-qubit refrigerator using the non-perturbative reaction-coordinate polaron transform (RCPT), which systematically captures strong-coupling effects through an exact mapping and dressing of a collective bath mode. We derive the renormalized qubit energy and effective dissipation rates, leading to a closed expression for the steady-state cooling power $$Q_{\text {c}}^{\text {RCPT}}(\lambda )$$ Q c RCPT ( λ ) . Numerical optimization reveals a critical coupling strength $$\lambda _{\text {c}} \approx 0.71$$ λ c ≈ 0.71 beyond which cooling performance deteriorates sharply. We analyze the impact of coupling strength on the maximum cooling power, the trade-off function $$\Omega$$ Ω , and a family of figures of merit $$\varepsilon ^I Q_{\text {c}}$$ ε I Q c . Our results establish the validity bounds of the weak-coupling approximation and demonstrate that excessive coupling suppresses energy extraction, providing essential guidelines for designing robust quantum thermal devices in the strong-coupling regime.

DOI
10.1140/epjp/s13360-026-07341-0

Related papers

Optimizing quantum thermodynamic cooling cycles

Luis Alfonso Correa

The study of nanoscopic thermal devices attracts an increasing attention, not only because of their key role in understanding the emergence of thermodynamics from quantum theory, but also for the potential use of quantum-mechanical thermal cycles, especially refrigerators, in quantum technologies. This thesis, is devoted to the performance optimization of autonomous (heat-driven) refrigerators. For a quantum refrigerator, one has a full microscopic description of the simple system serving as a working medium, and of its interaction with the external heat baths. This enables a consistent `finite-time? thermodynamic analysis, not relying on any phenomenological assumptions about the leading sources of irreversibility, and allows to establish arguably general performance bounds, essential to benchmark the operation of realistic devices. In particular, tight and model-independent upper bounds for the coefficient of performance at maximum power, are derived here for a class of strongly coupled refrigerators, and seen to hold more generally for other types of heat and power-driven cycles. Remarkably, these ultimate limitations only depend on the particulars of the system-baths interaction at the interface with the object to be cooled. Strategies might be then defined so as to saturate those limits: It is shown how the working medium of the refrigerator may be, for instance, scaled up into a parallel multi-stage configuration, resembling that of macroscopic multi-effect absorption chillers, as a means to increase its cooling power. Similarly, by applying reservoir engineering techniques on selected transitions between the energy states of the working medium, one can mimic exploitable non-equilibrium fluctuations in the baths, capable of boosting the overall power and COP beyond what would be otherwise allowed by the second law of thermodynamics. In this way, heat-driven chillers could be set to compete on a equal footing with the best power-driven refrigerators.

•Jan 1, 2014•0 citations

Strong system-bath coupling effects in quantum absorption refrigerators

Felix Ivander, Nicholas Anto-Sztrikacs, Dvira Segal

We study the performance of three-level quantum absorption refrigerators, paradigmatic autonomous quantum thermal machines, and reveal central impacts of strong couplings between the working system and the thermal baths. Using the reaction coordinate quantum master equation method, which treats system-bath interactions beyond weak coupling, we demonstrate that in a broad range of parameters the cooling window at strong coupling can be captured by a weak-coupling theory, albeit with parameters renormalized by the system-bath coupling energy. As a result, at strong system-bath couplings the window of cooling is significantly reshaped compared to predictions of weak-coupling treatments. We further show that strong coupling admits direct transport pathways between the thermal reservoirs. Such beyond-second-order transport mechanisms are typically detrimental to the performance of quantum thermal machines. Our study reveals that it is inadequate to claim for either a suppression or an enhancement of the cooling performance as one increases system-bath coupling-when analyzed against a single parameter and in a limited domain. Rather, a comprehensive approach should be adopted so as to uncover the reshaping of the operational window.

arXiv:2111.05302•Physical review. E•Mar 10, 2022•27 citations

Optimization of inverse one-qubit refrigerators

J. J. Fernández

Abstract We study several optimal working regimes of one-qubit quantum refrigerators having one qubit at their cold side. We demonstrate that they can be optimized using the techniques of finite-time thermodynamics on the solutions of the Lindblad equation. Our results show that differently to what happens in classic refrigerators, in our quantum ones the optimization of the cooling power does not lead to an optimal working regime but that using the $$\Omega$$ Ω function we can find it. Then, we generalize the study using a family of target functions defined by powers of the coefficient of performance times the cooling power to carry out a more general optimization. These last optimizations reveal the importance that every parameter defining the refrigerator has on the performance of the refrigerators when they work optimally.

The European Physical Journal Plus•May 26, 2025•1 citation

Optimal performance of endoreversible quantum refrigerators

Luis Alfonso Correa, José P. Palao, Gerardo Adesso +1 more

The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results that are model independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for any endoreversible quantum refrigerator. At striking variance with the universality of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.

arXiv:1408.0473•Physical Review E•Dec 17, 2014•54 citations

Performance bound for quantum absorption refrigerators

Luis Alfonso Correa, José P. Palao, Gerardo Adesso +1 more

An implementation of quantum absorption chillers with three qubits has been recently proposed that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modeling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.

arXiv:1212.4501•Physical Review E•Apr 29, 2013•177 citations

Impossibility of Refrigeration and Engine Operation in Minimal Qubit Repeated-Interaction Models

Gabrielle Barsky-Giles, Alessandro Prositto, Matthew Gerry +1 more

We investigate the operation of a qubit as a quantum thermal device within the repeated interaction framework, allowing for strong system-bath coupling and finite interaction times. We analyze two minimal models: an alternating-coupling setup, in which the qubit sequentially interacts with hot and cold baths, and a simultaneous-coupling setup, where both baths interact with the qubit during each collision. For the alternating model, we obtain an exact analytical solution for the limit-cycle state, valid for arbitrary coupling strengths and collision durations. Using this solution, we rigorously prove a no-go theorem for quantum refrigeration. We further demonstrate that, although work can be generated locally at individual system-bath contacts, the total work over a cycle is always nonpositive, precluding engine operation. In the absence of work, the model describes pure heat conduction, for which we derive a closed-form expression for the heat current and show that it exhibits a nonmonotonic turnover behavior. The simultaneous-coupling model is analyzed perturbatively. In the short-collision-time limit, it reproduces the same steady-state behavior as the alternating model, reinforcing the generality of the constraints identified. Our results establish fundamental limitations on qubit-based quantum thermal machines operating under Markovian repeated interactions and highlight the need for enriched models to realize functional quantum thermal devices.

quant-pharXiv:2602.18300•The Journal of Chemical Physics•Feb 23, 2026•1 citation
Abstract Real refrigerators operate in finite time, deviating from classical thermodynamics, which predicts zero cooling power at Carnot efficiency. Finite-time thermodynamics (FTT) addresses this by incorporating realistic constraints, but quantum extensions often rely on the weak-coupling approximation. This approximation fails in systems—such as superconducting circuits or nanomechanical resonators—where qubit-bath interactions are strong. To overcome this, we study a one-qubit refrigerator using the non-perturbative reaction-coordinate polaron transform (RCPT), which systematically captures strong-coupling effects through an exact mapping and dressing of a collective bath mode. We derive the renormalized qubit energy and effective dissipation rates, leading to a closed expression for the steady-state cooling power QcRCPT(λ)Q_{\text {c}}^{\text {RCPT}}(\lambda )QcRCPT​(λ) Q c RCPT ( λ ) . Numerical optimization reveals a critical coupling strength λc≈0.71\lambda _{\text {c}} \approx 0.71λc​≈0.71 λ c ≈ 0.71 beyond which cooling performance deteriorates sharply. We analyze the impact of coupling strength on the maximum cooling power, the trade-off function Ω\OmegaΩ Ω , and a family of figures of merit εIQc\varepsilon ^I Q_{\text {c}}εIQc​ ε I Q c . Our results establish the validity bounds of the weak-coupling approximation and demonstrate that excessive coupling suppresses energy extraction, providing essential guidelines for designing robust quantum thermal devices in the strong-coupling regime.
The study of nanoscopic thermal devices attracts an increasing attention, not only because of their key role in understanding the emergence of thermodynamics from quantum theory, but also for the potential use of quantum-mechanical thermal cycles, especially refrigerators, in quantum technologies. This thesis, is devoted to the performance optimization of autonomous (heat-driven) refrigerators. For a quantum refrigerator, one has a full microscopic description of the simple system serving as a working medium, and of its interaction with the external heat baths. This enables a consistent `finite-time? thermodynamic analysis, not relying on any phenomenological assumptions about the leading sources of irreversibility, and allows to establish arguably general performance bounds, essential to benchmark the operation of realistic devices. In particular, tight and model-independent upper bounds for the coefficient of performance at maximum power, are derived here for a class of strongly coupled refrigerators, and seen to hold more generally for other types of heat and power-driven cycles. Remarkably, these ultimate limitations only depend on the particulars of the system-baths interaction at the interface with the object to be cooled. Strategies might be then defined so as to saturate those limits: It is shown how the working medium of the refrigerator may be, for instance, scaled up into a parallel multi-stage configuration, resembling that of macroscopic multi-effect absorption chillers, as a means to increase its cooling power. Similarly, by applying reservoir engineering techniques on selected transitions between the energy states of the working medium, one can mimic exploitable non-equilibrium fluctuations in the baths, capable of boosting the overall power and COP beyond what would be otherwise allowed by the second law of thermodynamics. In this way, heat-driven chillers could be set to compete on a equal footing with the best power-driven refrigerators.
We study the performance of three-level quantum absorption refrigerators, paradigmatic autonomous quantum thermal machines, and reveal central impacts of strong couplings between the working system and the thermal baths. Using the reaction coordinate quantum master equation method, which treats system-bath interactions beyond weak coupling, we demonstrate that in a broad range of parameters the cooling window at strong coupling can be captured by a weak-coupling theory, albeit with parameters renormalized by the system-bath coupling energy. As a result, at strong system-bath couplings the window of cooling is significantly reshaped compared to predictions of weak-coupling treatments. We further show that strong coupling admits direct transport pathways between the thermal reservoirs. Such beyond-second-order transport mechanisms are typically detrimental to the performance of quantum thermal machines. Our study reveals that it is inadequate to claim for either a suppression or an enhancement of the cooling performance as one increases system-bath coupling-when analyzed against a single parameter and in a limited domain. Rather, a comprehensive approach should be adopted so as to uncover the reshaping of the operational window.
Abstract We study several optimal working regimes of one-qubit quantum refrigerators having one qubit at their cold side. We demonstrate that they can be optimized using the techniques of finite-time thermodynamics on the solutions of the Lindblad equation. Our results show that differently to what happens in classic refrigerators, in our quantum ones the optimization of the cooling power does not lead to an optimal working regime but that using the Ω\OmegaΩ Ω function we can find it. Then, we generalize the study using a family of target functions defined by powers of the coefficient of performance times the cooling power to carry out a more general optimization. These last optimizations reveal the importance that every parameter defining the refrigerator has on the performance of the refrigerators when they work optimally.
The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results that are model independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for any endoreversible quantum refrigerator. At striking variance with the universality of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.
An implementation of quantum absorption chillers with three qubits has been recently proposed that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modeling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.
We investigate the operation of a qubit as a quantum thermal device within the repeated interaction framework, allowing for strong system-bath coupling and finite interaction times. We analyze two minimal models: an alternating-coupling setup, in which the qubit sequentially interacts with hot and cold baths, and a simultaneous-coupling setup, where both baths interact with the qubit during each collision. For the alternating model, we obtain an exact analytical solution for the limit-cycle state, valid for arbitrary coupling strengths and collision durations. Using this solution, we rigorously prove a no-go theorem for quantum refrigeration. We further demonstrate that, although work can be generated locally at individual system-bath contacts, the total work over a cycle is always nonpositive, precluding engine operation. In the absence of work, the model describes pure heat conduction, for which we derive a closed-form expression for the heat current and show that it exhibits a nonmonotonic turnover behavior. The simultaneous-coupling model is analyzed perturbatively. In the short-collision-time limit, it reproduces the same steady-state behavior as the alternating model, reinforcing the generality of the constraints identified. Our results establish fundamental limitations on qubit-based quantum thermal machines operating under Markovian repeated interactions and highlight the need for enriched models to realize functional quantum thermal devices.