Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Electrical Engineering and Control Science (IC2ECS)

Count-Rate-Modulated NV-Diamond Quantum Magnetometry with Phase-Noise Suppression and Sensitivity Breakthrough

Ximing Gao, Wei Luo, Jiguang Zhao, Bing Tian, Liang Zhao, Bo Yang

Published Dec 5, 2025• 0 citations
Publisher

Abstract

Nitrogen-vacancy (NV) diamond magnetometry provides high sensitivity and room-temperature operation, yet its performance is limited by microwave inhomogeneity, phase noise, and nonlinear response under broadband conditions. This paper proposes a fluorescence count-rate modulation (FCM) strategy integrated with synchronized microwave control and FPGA-based timing, enabling enhanced spin manipulation efficiency, broadband phase-noise suppression, and robust sensitivity improvement. FCM introduces controlled perturbations to NV spin evolution via micro-pulse fluorescence modulation, accelerating Rabi dynamics and stabilizing optical readout. Experiments demonstrate improved coherence ($6.3 \mu \mathrm{~s}$), increased contrast (52.5%), and enhanced sensitivity (6.9 $\mathrm{nT} / \sqrt{ } \mathrm{Hz}$), outperforming intensity modulation (IM), dynamic decoupling (DD), and unmodulated schemes. The method maintains stability across $\mathbf{1 0 0}$-hour continuous operation and distinct environmental conditions. Results indicate that FCM provides a scalable pathway toward practical high-precision broadband quantum magnetometry.

DOI
10.1109/ic2ecs68700.2025.11362013

Related papers

Composite-pulse enhanced room-temperature diamond magnetometry

Yang Dong, Jingyan Xu, Shao-Chun Zhang +6 more

The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.

Functional Diamond•Jan 2, 2021•8 citations

Precision magnetometry and imaging via quantum manipulation of spins in diamond

Keigo Arai

.Precise control of quantum states is a cornerstone of quantum science and technology. Recently, a multi-level electronic spin system in a robust room-temperature solid, based on the nitrogen-vacancy (NV) color center in diamond, has emerged as a leading platform for quantum sensing as well as quantum information processing at room temperature. Developing new approaches to high-precision NV spin manipulation provides key insights for advancing these quantum technologies. In this thesis, I demonstrate three experimental methods for controlling NV spins with various concentrations toward high-performance magnetic field sensing and imaging. First, the wide-field optical magnetic microscopy experiment provides ensemble- NV control via continuous-wave electron spin resonance and camera-based parallel spin-state readout. This microscope offers a factor of 100 larger field-of-view compared to the confocal detection size, which enables magnetic imaging of populations of living bacteria. Second, the Fourier magnetic imaging experiment demonstrates for the first time multiple-NV control using phase encoding. Pulsed magnetic field gradients encode in the NV spin phase the information about the position of the NV centers as well as the external magnetic field in the Fourier-space. This scheme allows 100-fold improvement in spatial resolution beyond the optical diffraction limit, and has higher signal-to-noise ratio than other super-resolution imaging techniques when applied to NV spins. Third, the geometric phase magnetometry experiment employs single-NV control using a Berry sequence, consisting of off-resonant microwaves whose parameters vary along a cyclic path, thereby realizing 100 times larger magnetic field dynamic-range compared to the typical Ramsey-type interferometry approach. Finally, I discuss the possibilities of combining these techniques to realize various other quantum applications in future work.

•Jan 1, 2016•0 citations

High-sensitivity double-quantum magnetometry in diamond via quantum control

Yang Dong, Hao-Bin Lin, Wei Zhu +1 more

High-fidelity quantum operation of qubits plays an important role in magnetometry based on nitrogen-vacancy (NV) centers in diamonds. However, the nontrivial spin-spin coupling of the NV center decreases signal contrast and sensitivity. Here, we overcome this limitation by exploiting the amplitude modulation of microwaves, which allows us to perfectly detect magnetic signals at low fields. Compared with the traditional double-quantum sensing protocol, the full contrast of the detection signal was recovered, and the sensitivity was enhanced three times in the experiment. Our method is applicable to a wide range of sensing tasks, such as temperature, strain, and electric field.

JUSTC•Jan 1, 2022•1 citation

Toward T2-Limited DC Diamond Quantum Magnetometry via Flux Concentration and Modulation

Yijin Xie, Caijin Xie, Yunbin Zhu +7 more

High-sensitivity magnetometry is of critical importance to the fields of biomagnetism and geomagnetism. However, magnetometry for dc and low-frequency signal detection faces the challenge of sensitivity improvement, resulting from the low-frequency noise induced by multiple types of noise sources. In particular, for the solid-state spin dc quantum magnetometry, the sensitivity has been limited by short dephasing time. Here, we realized the conversion of the magnetic signal from dc to ac by utilizing a flux concentration and modulation (FCM) technique so that the dynamical decoupling method can be applied to prolong the dephasing time. Hence, we have successfully demonstrated a dc magnetometer with a sensitivity of 32 pT/Hz$^{{1}/{2}}$, which is about two orders of magnitude over that of the Ramsey-type dc magnetometer. Further enhancement of the sensitivity is systematically analyzed, although is challenging but plenty of room is achievable. Our results shed light on the realization of room temperature dc quantum magnetometry with femtotesla-sensitivity in the future.

arXiv:2204.07343•IEEE Sensors Journal•Aug 2, 2023•12 citations

QDsiM: A Noise-Aware Simulation Toolkit for Quantum Diamond Microscope

Satyam Pandey, Abhimanyu Magapu, Prabhat Anand +2 more

The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...

quant-pharXiv:2601.11649•Jan 16, 2026

Room-temperature Composite-pulses for Robust Diamond Magnetometry

Jingyan Xu, Dong, Yang, Shao-Chun Zhang +6 more

The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as $110\%$. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of $4$, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.

arXiv:1811.00191•Nov 1, 2018•3 citations
Nitrogen-vacancy (NV) diamond magnetometry provides high sensitivity and room-temperature operation, yet its performance is limited by microwave inhomogeneity, phase noise, and nonlinear response under broadband conditions. This paper proposes a fluorescence count-rate modulation (FCM) strategy integrated with synchronized microwave control and FPGA-based timing, enabling enhanced spin manipulation efficiency, broadband phase-noise suppression, and robust sensitivity improvement. FCM introduces controlled perturbations to NV spin evolution via micro-pulse fluorescence modulation, accelerating Rabi dynamics and stabilizing optical readout. Experiments demonstrate improved coherence (6.3μ s6.3 \mu \mathrm{~s}6.3μ s), increased contrast (52.5%), and enhanced sensitivity (6.9 nT/Hz\mathrm{nT} / \sqrt{ } \mathrm{Hz}nT/​Hz), outperforming intensity modulation (IM), dynamic decoupling (DD), and unmodulated schemes. The method maintains stability across 100\mathbf{1 0 0}100-hour continuous operation and distinct environmental conditions. Results indicate that FCM provides a scalable pathway toward practical high-precision broadband quantum magnetometry.
The sensitivity of practical solid quantum sensing can be boosted up by increasing the number of probes. However, the effects of spin dephasing caused by inhomogeneous broadening and imperfect quantum control can reduce the fidelity of quantum control and the sensitivity of quantum sensing with the dense ensemble of probes, such as nitrogen-vacancy (NV) centers in diamond. Here, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening and control errors via optimized modulation of the control field. Such a composite-pulse was verified on NV center to keep high fidelity quantum control up to a spectrum detuning as large as 110% of Rabi frequency. The sensitivity of the magnetometer with NV center ensemble was experimentally improved by a factor of 4, comparing to dynamical decoupling with a normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in practical applications. The used principle is universal and not restricted to NV center ensemble magnetometer.
.Precise control of quantum states is a cornerstone of quantum science and technology. Recently, a multi-level electronic spin system in a robust room-temperature solid, based on the nitrogen-vacancy (NV) color center in diamond, has emerged as a leading platform for quantum sensing as well as quantum information processing at room temperature. Developing new approaches to high-precision NV spin manipulation provides key insights for advancing these quantum technologies. In this thesis, I demonstrate three experimental methods for controlling NV spins with various concentrations toward high-performance magnetic field sensing and imaging. First, the wide-field optical magnetic microscopy experiment provides ensemble- NV control via continuous-wave electron spin resonance and camera-based parallel spin-state readout. This microscope offers a factor of 100 larger field-of-view compared to the confocal detection size, which enables magnetic imaging of populations of living bacteria. Second, the Fourier magnetic imaging experiment demonstrates for the first time multiple-NV control using phase encoding. Pulsed magnetic field gradients encode in the NV spin phase the information about the position of the NV centers as well as the external magnetic field in the Fourier-space. This scheme allows 100-fold improvement in spatial resolution beyond the optical diffraction limit, and has higher signal-to-noise ratio than other super-resolution imaging techniques when applied to NV spins. Third, the geometric phase magnetometry experiment employs single-NV control using a Berry sequence, consisting of off-resonant microwaves whose parameters vary along a cyclic path, thereby realizing 100 times larger magnetic field dynamic-range compared to the typical Ramsey-type interferometry approach. Finally, I discuss the possibilities of combining these techniques to realize various other quantum applications in future work.
High-fidelity quantum operation of qubits plays an important role in magnetometry based on nitrogen-vacancy (NV) centers in diamonds. However, the nontrivial spin-spin coupling of the NV center decreases signal contrast and sensitivity. Here, we overcome this limitation by exploiting the amplitude modulation of microwaves, which allows us to perfectly detect magnetic signals at low fields. Compared with the traditional double-quantum sensing protocol, the full contrast of the detection signal was recovered, and the sensitivity was enhanced three times in the experiment. Our method is applicable to a wide range of sensing tasks, such as temperature, strain, and electric field.
High-sensitivity magnetometry is of critical importance to the fields of biomagnetism and geomagnetism. However, magnetometry for dc and low-frequency signal detection faces the challenge of sensitivity improvement, resulting from the low-frequency noise induced by multiple types of noise sources. In particular, for the solid-state spin dc quantum magnetometry, the sensitivity has been limited by short dephasing time. Here, we realized the conversion of the magnetic signal from dc to ac by utilizing a flux concentration and modulation (FCM) technique so that the dynamical decoupling method can be applied to prolong the dephasing time. Hence, we have successfully demonstrated a dc magnetometer with a sensitivity of 32 pT/Hz1/2^{{1}/{2}}1/2, which is about two orders of magnitude over that of the Ramsey-type dc magnetometer. Further enhancement of the sensitivity is systematically analyzed, although is challenging but plenty of room is achievable. Our results shed light on the realization of room temperature dc quantum magnetometry with femtotesla-sensitivity in the future.
The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...
The sensitivity of a practical quantum magnetometer is challenged by both inhomogeneous coupling between sensors and environment and errors in quantum control. Based on the physical criteria of modern quantum sensing, we present a robust and effective composite-pulse for high fidelity operation against inhomogeneous broadening of sensor and control errors via optimized modulation of control field. Such a technique is verified on nitrogen-vacancy (NV) center in diamond to keep almost perfect operation up to a detuning as larger as 110%110\%110%. The sensitivity of the magnetometer with NV center ensemble is experimentally improved by a factor of 444, comparing to dynamical decoupling with normal rectangular pulse. Our work marks an important step towards high trustworthy ultra-sensitive quantum sensing with imperfect quantum control in realistic systems. The used principle however, is universal and not restricted to NV center ensemble magnetometer.