Electroencephalography (EEG) records brain activity linked to both executed and imagined movements, but separating true motor signals from background noise in high-dimensional EEG data remains a challenge. Reliable classifiers are therefore vital for accurately tracking patient progress over time. This work is part of a larger initiative, the Smart NeuroRehab Ecosystem, which has two primary goals: (1) to propose innovative physical-rehabilitation strategies for neurologic conditions such as stroke using emerging technologies that make therapy more accessible, and (2) to collect and analyze EEG data using machine learning (ML) models that classify movement-related brain signals. EEG data are complex and often difficult to interpret. In this research, we explore the use of quantum machine learning as an alternative approach for EEG signal classification. Compared to classical ML strategies, quantum methods may offer a fundamentally different way of representing and processing data, potentially improving classification performance or computational efficiency. We implement and analyze a ten-qubit Variational Quantum Classifier (VQC), and compare its performance to a tuned Random Forest baseline using EEG data from a publicly available 64-channel dataset. The task involves classifying each EEG time-window as either a movement or rest condition. Across 40 preliminary runs, the VQC achieves a macro-F1 score of approximately 0.75, accuracy of 0.76, and AUROC of 0.83, outperforming the Random Forest (macro-F1 ≈ 0.71, AUROC ≈ 0.79). In addition to higher macro-F1 and AUROC scores, the VQC also demonstrated significantly better precision and recall on the movement class, based on paired statistical tests. Most experiments were conducted on a quantum simulator, with a subset tested on a cloud-based quantum processor. These findings suggest that hybrid quantum-classical models can match or exceed the performance of tuned classical pipelines without increasing computational complexity. Within the scope of the Smart NeuroRehab project, this work demonstrates that quantum approaches may offer a practical path to continuous monitoring of EEG in clinical settings. Future improvements in quantum hardware may expand the range of practical applications in biomedical signal analysis.
Electroencephalography (EEG) records brain activity linked to both executed and imagined movements, but separating true motor signals from background noise in high-dimensional EEG data remains a challenge. Reliable classifiers are therefore vital for accurately tracking patient progress over time. This work is part of a larger initiative, the Smart NeuroRehab Ecosystem, which has two primary goals: (1) to propose innovative physical-rehabilitation strategies for neurologic conditions such as stroke using emerging technologies that make therapy more accessible, and (2) to collect and analyze EEG data using machine learning (ML) models that classify movement-related brain signals. EEG data are complex and often difficult to interpret. In this research, we explore the use of quantum machine learning as an alternative approach for EEG signal classification. Compared to classical ML strategies, quantum methods may offer a fundamentally different way of representing and processing data, potentially improving classification performance or computational efficiency. We implement and analyze a ten-qubit Variational Quantum Classifier (VQC), and compare its performance to a tuned Random Forest baseline using EEG data from a publicly available 64-channel dataset. The task involves classifying each EEG time-window as either a movement or rest condition. Across 40 preliminary runs, the VQC achieves a macro-F1 score of approximately 0.75, accuracy of 0.76, and AUROC of 0.83, outperforming the Random Forest (macro-F1 ≈ 0.71, AUROC ≈ 0.79). In addition to higher macro-F1 and AUROC scores, the VQC also demonstrated significantly better precision and recall on the movement class, based on paired statistical tests. Most experiments were conducted on a quantum simulator, with a subset tested on a cloud-based quantum processor. These findings suggest that hybrid quantum-classical models can match or exceed the performance of tuned classical pipelines without increasing computational complexity. Within the scope of the Smart NeuroRehab project, this work demonstrates that quantum approaches may offer a practical path to continuous monitoring of EEG in clinical settings. Future improvements in quantum hardware may expand the range of practical applications in biomedical signal analysis.
Electroencephalography (EEG) provides a powerful non-invasive modality for capturing millisecond-scale brain dynamics, yet traditional analysis pipelines often rely on hand-crafted features and classical models with limited ability to capture nonlinear dependencies. This study introduces Q-EEG, a novel quantum-enhanced computational framework for brain state classification. The proposed approach integrates classical pre-processing with quantum machine learning to exploit the representational capacity of quantum circuits. Raw EEG signals are first band-pass filtered into canonical rhythms—delta (0.5–4 Hz), theta (4–8 Hz), alpha (8–13 Hz), beta (13–30 Hz), and gamma (30–100 Hz)—and artefact removal is performed using ICA. Average band powers are then computed via the PSD and assembled into feature vectors. These normalized features are embedded in quantum states via rotation gates, forming the initial input to a VQC. The VQC models cross-frequency relationships using parameterised rotating layers and entangling operations, with weights trained using hybrid classical–quantum training with the parameter-shift rule and gradient-based optimisers. The computational basis classifies via measurements and evaluates the framework on seizure-versus-non-seizure detection tasks. Compared to SVM and Random Forest, accuracy, precision, recall, and F1-score are measured. Experimental results show that quantum-enhanced EEG analysis may capture complex brain patterns, enabling scalable, interpretable, and clinically useful diagnostic systems. This study shows that Q-EEG can bridge neuroscience with quantum computing, enabling clinical translation.
In neuroscience and therapeutic practice, electroencephalography (EEG) is a vital instrument for tracking and analysing brain activity. While traditional neural network models, like EEG-Net, have made significant progress in interpreting EEG signals, they frequently encounter difficulties due to the great dimensionality and complexity of the data. Quantum machine learning (QML) techniques offer new ways to improve machine learning models, thanks to recent developments in quantum computing. As a forward-looking approach, we present Quantum-EEG Net (QEEG Net), a novel hybrid neural network that combines quantum computing with the classical EEG Net architecture to improve EEG encoding and analysis. While the results may not always outperform conventional methods, it demonstrates its potential. In order to capture more complex patterns in EEG data and maybe provide computational benefits, QEEG Net integrates quantum layers into the neural network. Using the benchmark EEG dataset, BCI Competition IV 2a, we test QEEG Net and show that it consistently performs better than standard EEG-Net on the majority of participants and has other robustness to noise.
Electroencephalography is widely used in braincomputer interfaces, neurological research, and brain-state classification. However, EEG signals contain noise, artifacts, and variations between individuals, making accurate classification difficult. This project proposes an Adaptive Quantum Computing Framework for EEG Brain-State Classification Using Entanglement-Aware Feature Mapping. Initially, EEG signals are collected from publicly available datasets and preprocessed using filtering, artifact removal, segmentation, and normalization techniques. Relevant temporal and frequency-domain features are extracted and encoded into quantum states using parameterized quantum gates. An entanglement-aware featuremapping technique captures relationships between selected features through quantum entangling operations. A Variational Quantum Classifier is then employed to classify brain states using a hybrid quantum-classical optimization process. The adaptive mechanism evaluates different feature maps, entanglement patterns, circuit depths, and training parameters to identify suitable configurations. The proposed framework is evaluated using accuracy, precision, recall, macroF1 score, computational cost, and noise sensitivity. Classical machine learning and deep learning models are used for comparison. Subjectindependent testing assesses the model's ability to classify EEG signals from previously unseen participants. The study aims to investigate the effectiveness and limitations of adaptive quantum computing for EEG brain-state classification. Keywords: Quantum Computing, EEG Classification, Quantum Machine Learning, Entanglement-Aware Feature Mapping, Variational Quantum Classifier, Brain–Computer Interface.
Electroencephalography (EEG) is widely used in neuroscience and clinical research for analyzing brain activity. While deep learning models such as EEGNet have shown success in decoding EEG signals, they often struggle with data complexity, inter-subject variability, and noise robustness. Recent advancements in quantum machine learning (QML) offer new opportunities to enhance EEG analysis by leveraging quantum computing’s unique properties. In this study, we extend the previously proposed Quantum-EEGNet (QEEGNet), a hybrid neural network incorporating quantum layers into EEGNet, to investigate its generalization ability across multiple EEG datasets. Our evaluation spans a diverse set of cognitive and motor task datasets, assessing QEEGNet’s performance in different learning scenarios. Experimental results reveal that while QEEGNet demonstrates competitive performance and maintains robustness in certain datasets, its improvements over traditional deep learning methods remain inconsistent. These findings suggest that hybrid quantum-classical architectures require further optimization to fully leverage quantum advantages in EEG processing. Despite these limitations, our study provides new insights into the applicability of QML in EEG research and highlights challenges that must be addressed for future advancements.
Electroencephalography (EEG) is a critical tool in neuroscience and clinical practice for monitoring and analyzing brain activity. Traditional neural network models, such as EEG-Net, have achieved considerable success in decoding EEG signals but often struggle with the complexity and high dimensionality of the data. Recent advances in quantum computing present new opportunities to enhance machine learning models through quantum machine learning (QML) techniques. In this paper, we introduce Quantum-EEGNet (QEEGNet), a novel hybrid neural network that integrates quantum computing with the classical EEGNet architecture to improve EEG encoding and analysis, as a forward-looking approach, acknowledging that the results might not always surpass traditional methods but it shows its potential. QEEGNet incorporates quantum layers within the neural network, allowing it to capture more intricate patterns in EEG data and potentially offering computational advantages. We evaluate QEEGNet on a benchmark EEG dataset, BCI Competition IV 2a, demonstrating that it consistently outperforms traditional EEG-Net on most of the subjects and other robustness to noise. Our results highlight the significant potential of quantum-enhanced neural networks in EEG analysis, suggesting new directions for both research and practical applications in the field.
Purpose This study investigates the integration of quantum-enhanced machine learning (QML) into medical image analysis, focusing on classification and feature extraction tasks. It aims to evaluate whether hybrid quantum-classical models can overcome the limitations of traditional machine learning in handling high-dimensional, clinically relevant imaging data. Design/methodology/approach Hybrid architectures combining classical preprocessing with quantum components, specifically variational quantum circuits (VQCs) and quantum kernel methods, were developed and implemented in simulated quantum environments using Qiskit and PennyLane on Google Colab. Publicly available datasets (ChestX-ray14, Brain Tumor MRI and CT Hemorrhage) were preprocessed and encoded into quantum states. Model performance was evaluated against classical baselines (MLP and CNN) using accuracy, precision, recall, F1-score, convergence speed and trainable parameters. Findings Quantum-enhanced models achieved competitive or superior performance compared to classical models with significantly fewer trainable parameters and faster convergence. The Quantum Kernel SVM demonstrated the highest precision (89.1%) and F1-score (88.5%) using only 8 parameters, while VQC models converged up to 2× faster than classical baselines. These results highlight the potential of QML to improve efficiency, robustness and scalability in diagnostic imaging workflows, particularly in resource-constrained or data-limited settings. Research limitations/implications The study relies on simulated quantum environments, which do not capture hardware noise or qubit limitations. Future work will extend to real quantum devices, multimodal data integration and interpretability strategies. Practical implications Quantum kernel methods and lightweight VQC architectures enable faster, resource-efficient diagnostic modeling, making them suitable for clinical environments with limited computational capacity or time-sensitive decision-making needs. Social implications Improving the efficiency and accessibility of medical image analysis has the potential to support faster diagnosis and enhance healthcare delivery, particularly in underserved or resource-limited regions. Originality/value This study provides a practical evaluation of hybrid quantum-classical models applied to multiple real medical imaging datasets in a reproducible simulated environment. It offers an early-stage framework demonstrating how QML techniques can be integrated into existing machine learning pipelines for medical image analysis.