LaserPhys Youth School-Conference

Magneto-optical Hanle resonances on the transitions in 133Cs D1-line in an elliptically polarized light wave

Katerina Kozlova, Anton Makarov, Denis V. Brazhnikov, Andrei Goncharov

Published Jan 1, 2025• 0 citations
Publisher

Abstract

In current work magneto-optical Hanle resonances were registered in two experimental schemas: in classic light absorption in media was registered, in modified scheme with using elliptically polarized light an ellipticity change was recorded. For modified scheme sensitivity was estimated in two tranisition in the D1-line. The obtaained results can be used to create a highly sensitive magnetic sensor.

DOI
10.15862/83mnnpk25.19

Related papers

Features of magneto-optical resonances in an elliptically polarized traveling light wave

Denis V. Brazhnikov, A. V. Taǐchenachev, A. M. Tumaĭkin +5 more

The parameters of nonlinear absorption magneto-optical resonances in the Hanle configuration have been studied as functions of the ellipticity of a traveling light wave. It has been found that these parameters (amplitude, width, and amplitude-to-width ratio) depend strongly on the polarization of the light wave. In particular, the resonance amplitude can increase by more than an order of magnitude when the polarization changes from linear to optimal elliptic. It has been shown that this effect is associated with the Doppler frequency shift for atoms in a gas. The theoretical results have been corroborated in experiments in Rb vapor.

arXiv:quant-ph/0610053•Journal of Experimental and Theoretical Physics Letters•Mar 1, 2006•28 citations

Magneto-optical resonances in elliptically polarized light field

Denis V. Brazhnikov, А. В. Тайченачев, Anatolii M Tumaikin +4 more

Electromagnetically induced absorption (EIA) in Hanle configuration versus ellipticity of an optical running wave is investigated. All theoretical results are confirmed experimentally quite well. It is shown that magneto-optical resonance parameters (amplitude, width and amplitude-to-width ratio) depend on the wave polarization substantially. For example, the rsonance amplitude in the case of elliptic polarization of th elight wave can be the order more than for linear polarization.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2006•0 citations

Atomic magnetometry based on the ground-state Hanle effect in an elliptically polarized light wave

D. V. Brazhnikov, A. O. Makarov, K. S. Kozlova +1 more

We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature ($\approx\,$$0.125$ cm$^3$) glass cesium vapor cell heated to a relatively low temperature of $\approx\,$$85^\circ$C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching $180$ fT/$\surd$Hz in a $200$ Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be $\approx\,$$5$ fT/$\surd$Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.

physics.atom-phCross-listedarXiv:2511.18710•The European Physical Journal D•Nov 25, 2025•0 citations

Electromagnetically Induced Absorption in an Elliptically Polarized Light Field

Denis V. Brazhnikov, A. V. Taichenachev, Anatolii M Tumaikin +4 more

Electromagnetically induced absorption (EIA) in Hanle configuration versus ellipticity of an optical running wave is investigated. All theoretical results are confirmed experimentally quite well. It is shown that magneto-optical resonance parameters (amplitude, width and amplitude-to-width ratio) depend on the wave polarization substantially. For example, the resonance amplitude in the case of elliptic polarization of the light wave can be the order more than for linear polarization.

International Scientific-Technical Conference on Actual Problems of Electronic Instrument Engineering (APEIE)•Sep 1, 2006•0 citations

Electromagnetically Induced Absorption in an Elliptically Polarized Light Field

Denis V. Brazhnikov, А. В. Тайченачев, Anatolii M Tumaikin +4 more

Electromagnetically induced absorption (EIA) in Hanle configuration versus ellipticity of an optical running wave is investigated. All theoretical results are confirmed experimentally quite well. It is shown that magneto-optical resonance parameters (amplitude, width and amplitude-to-width ratio) depend on the wave polarization substantially. For example, the resonance amplitude in the case of elliptic polarization of the light wave can be the order more than for linear polarization.

International Scientific-Technical Conference on Actual Problems of Electronic Instrument Engineering (APEIE)•Sep 1, 2006•0 citations

Coherent magneto-optical resonances on the potassium D2 line in modified hanle configuration for magnetometry applications

S. Tsvetkov, C. Andreeva, S. Gateva

Experimental investigation of magneto-optical resonances on the potassium D2 line with λ=766.7 nm from the point of view of magnetometry applications is reported. The resonances are registered in a modified Hanle effect configuration based on counterpropagating pump and probe laser beams with orthogonal linear polarizations in a buffer gas cell with dimensions (diameter and length) of 8 mm. The amplitude, width, and contrast of the resonances registered in fluorescence and transmission are measured. The transformation of the bright magneto-optical resonances detected in fluorescence to dark ones by controlling the optical thickness of potassium vapor is analyzed. The influence of the laser intensity, buffer gas, and transverse magnetic field are considered. The experimental results show the system’s potential for magnetic field sensing and self-calibration.

AIP conference proceedings•Jan 1, 2024•0 citations
In current work magneto-optical Hanle resonances were registered in two experimental schemas: in classic light absorption in media was registered, in modified scheme with using elliptically polarized light an ellipticity change was recorded. For modified scheme sensitivity was estimated in two tranisition in the D1-line. The obtaained results can be used to create a highly sensitive magnetic sensor.
The parameters of nonlinear absorption magneto-optical resonances in the Hanle configuration have been studied as functions of the ellipticity of a traveling light wave. It has been found that these parameters (amplitude, width, and amplitude-to-width ratio) depend strongly on the polarization of the light wave. In particular, the resonance amplitude can increase by more than an order of magnitude when the polarization changes from linear to optimal elliptic. It has been shown that this effect is associated with the Doppler frequency shift for atoms in a gas. The theoretical results have been corroborated in experiments in Rb vapor.
We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature (≈ \approx\,≈0.1250.1250.125 cm3^33) glass cesium vapor cell heated to a relatively low temperature of ≈ \approx\,≈85∘85^\circ85∘C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching 180180180 fT/√\surd√Hz in a 200200200 Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be ≈ \approx\,≈555 fT/√\surd√Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.
Experimental investigation of magneto-optical resonances on the potassium D2 line with λ=766.7 nm from the point of view of magnetometry applications is reported. The resonances are registered in a modified Hanle effect configuration based on counterpropagating pump and probe laser beams with orthogonal linear polarizations in a buffer gas cell with dimensions (diameter and length) of 8 mm. The amplitude, width, and contrast of the resonances registered in fluorescence and transmission are measured. The transformation of the bright magneto-optical resonances detected in fluorescence to dark ones by controlling the optical thickness of potassium vapor is analyzed. The influence of the laser intensity, buffer gas, and transverse magnetic field are considered. The experimental results show the system’s potential for magnetic field sensing and self-calibration.