Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Quantum-induced coherence imaging with a long interference region

Yansheng Bao, Bochen Wang, Ze Min Wu, Changyong Tian, Yani Zuo, Zhengyong Li

Published Jan 20, 2026• 0 citations
Publisher

Abstract

Zou-Wang-Mandel (ZWM) quantum-induced coherence has been demonstrated for high-sensitive detection and sensing applications such as high signal-to-noise ratio ranging and imaging in complex environments. The path overlapping of the idler prohibits the determination of the exact path from which the signal originates. However, the interference region of quantum-induced coherence is limited to coherence length of parametric down-conversion (PDC) photons generated by nonlinear processes, which has remained an urgent issue to address. Here, we propose a method to increase the interference region of quantum-induced coherence imaging systems, from micrometers to centimeters at least by seed injection (SI) of the same frequency as the idler, and resulting in brighter fringes. Compared to typical ZWM quantum-induced coherence imaging, our system not only retains the advantages of noise resistance and no coincidence requirement but also exhibits possibilities of high-coherence, long-distance, and high-visibility imaging.

DOI
10.1364/ol.581283

Related papers

Heralded Induced-Coherence Interferometry in a Noisy Environment

L. Theerthagiri, Balakrishnan Viswanathan, C. M. Chandrashekar

Induced-coherence interferometry, first introduced in the Zou-Wang-Mandel (ZWM) setup, enables retrieval of object information from the interference pattern of light that never interacted with the object. This scheme relies on two identically correlated photon pairs and the absence of "which-way" information about the photons illuminating the object to induce coherence in their companions. In previous studies, the effect of thermal background on the ZWM interferometer was considered; here we explicitly include background noise and analyze the interference visibility in both low- and high-gain regimes, revealing how thermal photons introduce an incoherent offset that lowers the observed interference contrast. We show that the visibility can be restored either by optimal attenuation or by extending the geometry to a three-SPDC configuration. Furthermore, we demonstrate that introducing heralded detection removes the detrimental effect of thermal background noise, restoring high-contrast interference fringes.

quant-pharXiv:2511.03176•Nov 6, 2025•2 citations

Quantum Induced Coherence Light Detection and Ranging

Gewei Qian, Xingqi Xu, Shun-An Zhu +6 more

Quantum illumination has been proposed and demonstrated to improve the signal-to-noise ratio (SNR) in light detection and ranging (LiDAR). When relying on coincidence detection alone, such a quantum LiDAR is limited by the timing jitter of the detector and suffers from jamming noise. Inspired by the Zou-Wang-Mandel experiment, we design, construct, and validate a quantum induced coherence (QuIC) LiDAR which is inherently immune to ambient and jamming noises. In traditional LiDAR the direct detection of the reflected probe photons suffers from deteriorating SNR for increasing background noise. In QuIC LiDAR we circumvent this obstacle by only detecting the entangled reference photons, whose single-photon interference fringes are used to obtain the distance of the object, while the reflected probe photons are used to erase path information of the reference photons. In consequence, the noise accompanying the reflected probe light has no effect on the detected signal. We demonstrate such noise resilience with both LED and laser light to mimic the background and jamming noise. The proposed method paves a new way of battling noise in precise quantum electromagnetic sensing and ranging.

arXiv:2212.12924•Physical Review Letters•Jul 18, 2023•41 citations

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.

quant-pharXiv:2512.19637•APL Photonics•Dec 23, 2025•2 citations

Controlling induced coherence for quantum imaging

Mikhail I. Kolobov, Enno Giese, Samuel Lemieux +2 more

Abstract Induced coherence in parametric down-conversion between two coherently pumped nonlinear crystals that share a common idler mode can be used as an imaging technique. Based on the interference between the two signal modes of the crystals, an image can be reconstructed. By obtaining an expression for the interference pattern that is valid in both the low- and the high-gain regimes of parametric down-conversion, we show how the coherence of the light emitted by the two crystals can be controlled. With our comprehensive analysis we provide deeper insight into recent discussions about the application of induced coherence to imaging in different regimes. Moreover, we propose a scheme for optimizing the visibility of the interference pattern so that it directly corresponds to the degree of coherence of the light generated in the two crystals. We find that this scheme leads in the high-gain regime to a visibility arbitrarily close to unity.

arXiv:1702.07742•Journal of Optics•Mar 6, 2017•43 citations

New progress in quantum imaging with undetected photons (Conference Presentation)

Markus Gräfe, Marta Gilaberte Basset, Josué R. León Torres

Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.

Quantum Communications and Quantum Imaging•Sep 10, 2019•0 citations

Quantum optical induced-coherence tomography by a hybrid interferometer

Eun Mi Kim, Sun Kyung Lee, Sang Min Lee +2 more

Abstract Quantum interferometry based on induced-coherence phenomena has demonstrated the possibility of undetected-photon measurements. Perturbation in the optical path of probe photons can be detected by interference signals generated by quantum mechanically correlated twin photons propagating through a different path, possibly at a different wavelength. To the best of our knowledge, this work demonstrates for the first time a hybrid-type induced-coherence interferometer that incorporates a Mach–Zehnder-type interferometer for near-visible photons and a Michelson-type interferometer for infrared (IR) photons, based on double-pass-pumped spontaneous parametric down-conversion. This configuration enables IR optical measurements via the detection of near-visible photons and provides methods for optimizing the quality of measurements by identifying photon pairs of different origins. We theoretically identify that the induced-coherence interference visibility is approximately the same as the heralding efficiency between twin photons along the relevant spatial modes, and experimentally maximize the visibility by setting up a common reference spatial mode for IR photons. Applications to both time-domain and frequency-domain quantum optical induced-coherence tomography for three-dimensional test structures are demonstrated. The results prove the feasibility of practical undetected-photon sensing and imaging techniques based on the presented structure.

arXiv:2309.06777•Quantum Science and Technology•Dec 5, 2023•11 citations
Zou-Wang-Mandel (ZWM) quantum-induced coherence has been demonstrated for high-sensitive detection and sensing applications such as high signal-to-noise ratio ranging and imaging in complex environments. The path overlapping of the idler prohibits the determination of the exact path from which the signal originates. However, the interference region of quantum-induced coherence is limited to coherence length of parametric down-conversion (PDC) photons generated by nonlinear processes, which has remained an urgent issue to address. Here, we propose a method to increase the interference region of quantum-induced coherence imaging systems, from micrometers to centimeters at least by seed injection (SI) of the same frequency as the idler, and resulting in brighter fringes. Compared to typical ZWM quantum-induced coherence imaging, our system not only retains the advantages of noise resistance and no coincidence requirement but also exhibits possibilities of high-coherence, long-distance, and high-visibility imaging.
Induced-coherence interferometry, first introduced in the Zou-Wang-Mandel (ZWM) setup, enables retrieval of object information from the interference pattern of light that never interacted with the object. This scheme relies on two identically correlated photon pairs and the absence of "which-way" information about the photons illuminating the object to induce coherence in their companions. In previous studies, the effect of thermal background on the ZWM interferometer was considered; here we explicitly include background noise and analyze the interference visibility in both low- and high-gain regimes, revealing how thermal photons introduce an incoherent offset that lowers the observed interference contrast. We show that the visibility can be restored either by optimal attenuation or by extending the geometry to a three-SPDC configuration. Furthermore, we demonstrate that introducing heralded detection removes the detrimental effect of thermal background noise, restoring high-contrast interference fringes.
Quantum illumination has been proposed and demonstrated to improve the signal-to-noise ratio (SNR) in light detection and ranging (LiDAR). When relying on coincidence detection alone, such a quantum LiDAR is limited by the timing jitter of the detector and suffers from jamming noise. Inspired by the Zou-Wang-Mandel experiment, we design, construct, and validate a quantum induced coherence (QuIC) LiDAR which is inherently immune to ambient and jamming noises. In traditional LiDAR the direct detection of the reflected probe photons suffers from deteriorating SNR for increasing background noise. In QuIC LiDAR we circumvent this obstacle by only detecting the entangled reference photons, whose single-photon interference fringes are used to obtain the distance of the object, while the reflected probe photons are used to erase path information of the reference photons. In consequence, the noise accompanying the reflected probe light has no effect on the detected signal. We demonstrate such noise resilience with both LED and laser light to mimic the background and jamming noise. The proposed method paves a new way of battling noise in precise quantum electromagnetic sensing and ranging.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
Abstract Induced coherence in parametric down-conversion between two coherently pumped nonlinear crystals that share a common idler mode can be used as an imaging technique. Based on the interference between the two signal modes of the crystals, an image can be reconstructed. By obtaining an expression for the interference pattern that is valid in both the low- and the high-gain regimes of parametric down-conversion, we show how the coherence of the light emitted by the two crystals can be controlled. With our comprehensive analysis we provide deeper insight into recent discussions about the application of induced coherence to imaging in different regimes. Moreover, we propose a scheme for optimizing the visibility of the interference pattern so that it directly corresponds to the degree of coherence of the light generated in the two crystals. We find that this scheme leads in the high-gain regime to a visibility arbitrarily close to unity.
Since the second quantum revolution, the growing exploitation of quantum states led to many sophisticated and novel applications [Phil. Trans. R. Soc. Lond. A 361, 1655 (2003). Former, mainly academic research is more and more transferred into real-world quantum technology ready to serve practical tasks. Today, the quantum computer is within reach, satellite based quantum communication already started, and the field of sensing and imaging was revolutionized, too. Non-classical states of light promise a phase sensitivity beyond any classical possibility [PRL 112, 103604 (2014)] and super-resolution capability [Nature Commun. 8, 14786 (2017)]. Moreover, based on quantum correlations, which are rooted in the very heart of quantum mechanics, the imaging of samples with photons that have never interacted with the object is feasible. This science fiction like phenomenon was first investigated by Mandel [PRA 44, 4614 (1991)] and later implemented for actual imaging purposes in the Zeilinger group [Nature 512, 409 (2014)]. We are going to present the transfer of this approach into applicable quantum technology within the realm of the Fraunhofer Key Research Initiative Quantum Methods for Advanced Imaging Solutions (QUILT). The method itself is based on induced coherence without induced emission [PRA 44, 4614 (1991)]. We built a novel compact implementation of this scheme based on only one nonlinear crystal. The crystal is coherently pumped by a laser from two sides such that signal and idler photon pairs can be collinearly emitted in either of two opposite directions (to the right or to the left). On the right side the idler beam will be separated by a dichroic mirror (DM) and interacts with an object (directly placed in front of a mirror or reflective object). On the left side the signal beam will be separated by another dichroic mirror and hit the camera, which is either a sCMOS or an EMCCD. Additional lenses provide the particular imaging. Sine the two possibilities for the idler beam – going right and interact with the object or going left from the nonlinear crystal – interfere the object could be observed by idler detection. However, the same interference can be observed for the signal beams although the never interacted with the object. Hence, the object can be imaged by detecting the signal light only. The crucial point here is the lack of wich-path information of the idler beams in this type of Michelson interferometric setup. The following points should be emphasized: (i) the signal channels never interact with the object, (ii) there is no induced emission due to the idler beam that interacted with the object, and (iii) there is no coincidence detection involved in this scheme. The obvious advantage of this technique is that the wavelength of the idler photons can be tailored to match the interesting spectral range for interaction with the object. At the same time, the signal photons, which are actually detected, can stay in the VIS range where, e.g., Si-based detectors are optimized. Besides the application for life science imaging, we are comparing the quantum imaging properties utilizing momentum correlations or spatial correlations, where the ladder is a modus that was never investigated before. As an outlook we work on significantly enhance SPDC sources in scope of quantum performance and wavelength separation. Obviously, pushing the short-wavelength idler photons further into the deep UV or XUV broadens the range of applications, but must be implemented by non-SPDC photon pair sources.
Abstract Quantum interferometry based on induced-coherence phenomena has demonstrated the possibility of undetected-photon measurements. Perturbation in the optical path of probe photons can be detected by interference signals generated by quantum mechanically correlated twin photons propagating through a different path, possibly at a different wavelength. To the best of our knowledge, this work demonstrates for the first time a hybrid-type induced-coherence interferometer that incorporates a Mach–Zehnder-type interferometer for near-visible photons and a Michelson-type interferometer for infrared (IR) photons, based on double-pass-pumped spontaneous parametric down-conversion. This configuration enables IR optical measurements via the detection of near-visible photons and provides methods for optimizing the quality of measurements by identifying photon pairs of different origins. We theoretically identify that the induced-coherence interference visibility is approximately the same as the heralding efficiency between twin photons along the relevant spatial modes, and experimentally maximize the visibility by setting up a common reference spatial mode for IR photons. Applications to both time-domain and frequency-domain quantum optical induced-coherence tomography for three-dimensional test structures are demonstrated. The results prove the feasibility of practical undetected-photon sensing and imaging techniques based on the presented structure.