Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Oscilador paramétrico óptico baseado em um processo degenerado de mistura de quatro ondas em átomos

Pedro Enrique Piñeros Lourenço

Published Sep 24, 2025• 0 citations
OpenAlex

Abstract

We have implemented the degenerate version of an optical parametric oscillator (OPO) based on hot Rubidium atoms. Here we present the characterization of the output power as a function of the input power. From this characterization, we observed a soft transition between below and above threshold oscillation for situations in which the OPO cavity finesse is small. Furthermore, we show quadrature noise measurements performed by resonator detection of the beam produced on the OPO. Moreover, we studied near and below threshold regime through homodyne detection to analyze noise compression and Gaussian statistics of the photocurrent. Our results show that in the degenerate operation above threshold we obtained excess in amplitude and phase quadratures. On the other hand, we measured 6% of noise compression in phase quadrature below threshold. We discuss some sources of excess noise that affect the system, and we explore strategies to mitigate this noise. In general, the finesse of the OPO cavity allows us to observe the atomic contribution to the output noise spectrum. Also, they do not reveal evidence of sidebands entanglement or non-Gaussian features. However, we outline a pathway toward the improvement of the degenerate atomic OPO for direct generation of squeezed states, with potential applications for quantum sensing.

Related papers

Quantum Noise Correlations of an Optical Parametric Oscillator Based on a Nondegenerate Four Wave Mixing Process in Hot Alkali Atoms

Alvaro Montaña Guerrero, P. Nussenzveig, M. Martinelli +2 more

We present the first measurement of two-mode squeezing between the twin beams produced by a doubly resonant optical parameter oscillator (OPO) in an above threshold operation based on parametric amplification by nondegenerate four wave mixing with rubidium (^{85}Rb). We demonstrate a maximum intensity difference squeezing of -2.7 dB (-3.5 dB corrected for losses) with a pump power of 285 mW and an output power of 12 mW for each beam, operating close to the D1 line of Rb atoms. The use of open cavities combined with the high gain media can provide a strong level of noise compression and the access to new operation regimes that could not be explored by crystal based OPOs. The spectral bandwidth of the squeezed light is broadened by the cavity dynamics, and the squeezing level is robust for strong pump powers. Stable operation was obtained up to 4 times above the threshold. Moreover, operation of the OPO close to the atomic resonances of alkali atoms allows a natural integration into quantum networks, including structures such as quantum memories.

arXiv:2004.01590•Physical Review Letters•Aug 21, 2020•27 citations

Pump noise in an optical parametric oscillator operated above threshold

K. W. Leong, N. C. Wong, Jeffrey H. Shapiro

A cw optical parametric oscillator (OPO) operated above threshold is of particular interest in current squeezing experiments. Quadrature squeezing in the signal and idler modes and in the pump mode is predicted. Intensity squeezing in the difference intensity of the signal and idler is predicted and has recently been observed.1 We have built a doubly resonant cw OPO with a magnesium oxide- doped lithium niobate crystal that is single-pass-pumped with the 530.9-nm line of a kryptonion laser. Mode hopping instability near degeneracy puts stringent requirements on the frequency stability of the pump laser and the mechanical stability of the OPO cavity. We have oberved such instability near degeneracy and determined the stability requirements for this OPO. Stable operation can be obtained as the OPO is operated away from degeneracy but at a higher threshold. Classically the single-pass pump output is predicted to be clamped at the threshold value so that the OPO in this configuration acts as a pump power limiter. Quantum mechanically, we have found that the pump intensity noise is enhanced. Measurements on the pump intensity noise spectrum in this particular configuration have been made and compared to our theoretical predictions.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Non-Gaussian states produced by close-to-threshold optical parametric oscillators: Role of classical and quantum fluctuations

Virginia D’Auria, Corrado de Lisio, A. Porzio +3 more

Quantum states with non-Gaussian statistics generated by optical parametric oscillators (OPO) with fluctuating parameters are studied by means of the kurtosis excess of the external field quadratures. The field generated is viewed as the response of a nonlinear device to the fluctuations of pump laser amplitude and frequency, crystal temperature, and cavity detuning, in addition to quantum noise sources. The kurtosis excess has been evaluated perturbatively up to the third order in the strength of the crystal nonlinear coupling factor and the second order in the classical fluctuating parameters. Applied to the device described in Opt. Expr. 13, 948 (2005), the model has given values of the kurtosis excess in good agreement with the measured ones.

arXiv:0907.3825•Physical Review A•Mar 29, 2010•27 citations

Microwave Frequency Characterisation of Squeezed Light From an Optical Parametric Oscillator

Roger Senior

The quantum statistics of a laser result in noise when measurements of the beam are made. This noise sets a classical limit beyond which a laser cannot be used with increasing sensitivity. This quantum noise limit is imposed on many of the uses of lasers currently, especially in power limited devices such as optical communications. The statistics of the laser photon field can be modified to produce a non-classical state resulting in lower noise than the quantum noise limit when detected appropriately. This state, called a squeezed state, has been measured previously from a cavity enhanced optical parametric oscillator (OPO) only at frequency sidebands within the linewidth of the cavity. ¶ This thesis reports measurements of squeezing at microwave frequency sidebands on an optical beam produced by an optical parametric oscillator. This is the first reported measurement of squeezing at frequency sidebands at higher longitudinal modes of the cavity from an OPO. Noise reduction below the quantum noise limit is measured at sideband frequencies of 5 MHz, 1.7 GHz, 3.4 GHz and 5.1 GHz, corresponding to the zeroth, first, second and third longitudinal modes from the squeezed beam. These results are the highest frequency sideband measurements of squeezing to date. In addition to measuring squeezing at different longitudinal modes for the fundamental Gaussian spatial mode, non-classical noise reduction is measured at the same frequencies for a squeezed higher order spatial mode, TEM10. ¶ A single mode theoretical model of the OPO is presented, based on the work of ref. [1]. Computer simulations of the squeezing predicted by this model are developed and compared to the experimental results, showing excellent agreement between the different longitudinal modes for each of the two spatial modes measured.

•Jan 1, 2006•0 citations

Compact source of Einstein-Podolsky-Rosen entanglement and squeezing at very low noise frequencies

Julien Laurat, T. Coudreau, G. Keller +2 more

We report on the experimental demonstration of strong quadrature Einstein-Podolsky-Rosen entanglement and squeezing at very low noise sideband frequencies produced by a single type-II, self-phase-locked, frequency degenerate optical parametric oscillator below threshold. The generated two-mode squeezed vacuum state is preserved for noise frequencies as low as $50\phantom{\rule{0.3em}{0ex}}\mathrm{kHz}$. Designing simple setups able to generate nonclassical states of light in the kHz regime is a key challenge for high sensitivity detection of ultraweak physical effects such as gravitational wave or small beam displacement.

arXiv:quant-ph/0403224•Physical Review A•Oct 25, 2004•67 citations

Generation of squeezed states at low analysis frequencies

Xin Wen, Yashuai Han, Liu Jin-Yu +3 more

Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.

Acta Physica Sinica•Jan 1, 2018•4 citations
We have implemented the degenerate version of an optical parametric oscillator (OPO) based on hot Rubidium atoms. Here we present the characterization of the output power as a function of the input power. From this characterization, we observed a soft transition between below and above threshold oscillation for situations in which the OPO cavity finesse is small. Furthermore, we show quadrature noise measurements performed by resonator detection of the beam produced on the OPO. Moreover, we studied near and below threshold regime through homodyne detection to analyze noise compression and Gaussian statistics of the photocurrent. Our results show that in the degenerate operation above threshold we obtained excess in amplitude and phase quadratures. On the other hand, we measured 6% of noise compression in phase quadrature below threshold. We discuss some sources of excess noise that affect the system, and we explore strategies to mitigate this noise. In general, the finesse of the OPO cavity allows us to observe the atomic contribution to the output noise spectrum. Also, they do not reveal evidence of sidebands entanglement or non-Gaussian features. However, we outline a pathway toward the improvement of the degenerate atomic OPO for direct generation of squeezed states, with potential applications for quantum sensing.
We present the first measurement of two-mode squeezing between the twin beams produced by a doubly resonant optical parameter oscillator (OPO) in an above threshold operation based on parametric amplification by nondegenerate four wave mixing with rubidium (^{85}Rb). We demonstrate a maximum intensity difference squeezing of -2.7 dB (-3.5 dB corrected for losses) with a pump power of 285 mW and an output power of 12 mW for each beam, operating close to the D1 line of Rb atoms. The use of open cavities combined with the high gain media can provide a strong level of noise compression and the access to new operation regimes that could not be explored by crystal based OPOs. The spectral bandwidth of the squeezed light is broadened by the cavity dynamics, and the squeezing level is robust for strong pump powers. Stable operation was obtained up to 4 times above the threshold. Moreover, operation of the OPO close to the atomic resonances of alkali atoms allows a natural integration into quantum networks, including structures such as quantum memories.
A cw optical parametric oscillator (OPO) operated above threshold is of particular interest in current squeezing experiments. Quadrature squeezing in the signal and idler modes and in the pump mode is predicted. Intensity squeezing in the difference intensity of the signal and idler is predicted and has recently been observed.1 We have built a doubly resonant cw OPO with a magnesium oxide- doped lithium niobate crystal that is single-pass-pumped with the 530.9-nm line of a kryptonion laser. Mode hopping instability near degeneracy puts stringent requirements on the frequency stability of the pump laser and the mechanical stability of the OPO cavity. We have oberved such instability near degeneracy and determined the stability requirements for this OPO. Stable operation can be obtained as the OPO is operated away from degeneracy but at a higher threshold. Classically the single-pass pump output is predicted to be clamped at the threshold value so that the OPO in this configuration acts as a pump power limiter. Quantum mechanically, we have found that the pump intensity noise is enhanced. Measurements on the pump intensity noise spectrum in this particular configuration have been made and compared to our theoretical predictions.
Quantum states with non-Gaussian statistics generated by optical parametric oscillators (OPO) with fluctuating parameters are studied by means of the kurtosis excess of the external field quadratures. The field generated is viewed as the response of a nonlinear device to the fluctuations of pump laser amplitude and frequency, crystal temperature, and cavity detuning, in addition to quantum noise sources. The kurtosis excess has been evaluated perturbatively up to the third order in the strength of the crystal nonlinear coupling factor and the second order in the classical fluctuating parameters. Applied to the device described in Opt. Expr. 13, 948 (2005), the model has given values of the kurtosis excess in good agreement with the measured ones.
The quantum statistics of a laser result in noise when measurements of the beam are made. This noise sets a classical limit beyond which a laser cannot be used with increasing sensitivity. This quantum noise limit is imposed on many of the uses of lasers currently, especially in power limited devices such as optical communications. The statistics of the laser photon field can be modified to produce a non-classical state resulting in lower noise than the quantum noise limit when detected appropriately. This state, called a squeezed state, has been measured previously from a cavity enhanced optical parametric oscillator (OPO) only at frequency sidebands within the linewidth of the cavity. ¶ This thesis reports measurements of squeezing at microwave frequency sidebands on an optical beam produced by an optical parametric oscillator. This is the first reported measurement of squeezing at frequency sidebands at higher longitudinal modes of the cavity from an OPO. Noise reduction below the quantum noise limit is measured at sideband frequencies of 5 MHz, 1.7 GHz, 3.4 GHz and 5.1 GHz, corresponding to the zeroth, first, second and third longitudinal modes from the squeezed beam. These results are the highest frequency sideband measurements of squeezing to date. In addition to measuring squeezing at different longitudinal modes for the fundamental Gaussian spatial mode, non-classical noise reduction is measured at the same frequencies for a squeezed higher order spatial mode, TEM10. ¶ A single mode theoretical model of the OPO is presented, based on the work of ref. [1]. Computer simulations of the squeezing predicted by this model are developed and compared to the experimental results, showing excellent agreement between the different longitudinal modes for each of the two spatial modes measured.
We report on the experimental demonstration of strong quadrature Einstein-Podolsky-Rosen entanglement and squeezing at very low noise sideband frequencies produced by a single type-II, self-phase-locked, frequency degenerate optical parametric oscillator below threshold. The generated two-mode squeezed vacuum state is preserved for noise frequencies as low as 50kHz50\phantom{\rule{0.3em}{0ex}}\mathrm{kHz}50kHz. Designing simple setups able to generate nonclassical states of light in the kHz regime is a key challenge for high sensitivity detection of ultraweak physical effects such as gravitational wave or small beam displacement.
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.