Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Scalable Multi-Loop Cold Atom Rotation Sensor

Rühmann, Sandra, Ahlers, Holger, Deppner, Christian, Herr, Waldemar, Schubert, Christian

Published Mar 1, 2025• 0 citations
OpenAlex

Abstract

Matter-wave interferometry with cold atoms offers a competitive tool for absolute measurements of acceleration and rotation. The sensitivity of atom-interferometric gyroscopes depends on the area enclosed by the interferometer. In this contribution, we present a concept for a rotation sensor, utilizing a multi-loop interferometer geometry to achieve a scalable area while maintaining a compact setup. It enables rotation measurements of a single axis on ground and can be extended to measure rotations along all three spatial axes in microgravity, for potential applications in space missions, Earth observation, and navigation systems.

Related papers

Development of compact cold-atom sensors for inertial navigation

Baptiste Battelier, B. Barrett, Lauriane Fouché +7 more

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.

arXiv:1605.02454•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•84 citations

Multi-loop atomic Sagnac interferometry

Christian Schubert, Sven Abend, Matthias Gersemann +4 more

The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.

arXiv:2102.00991•Scientific Reports•Aug 9, 2021•35 citations

Atom interferometry at arbitrary orientations and rotation rates

Quentin d’Armagnac de Castanet, Cyrille Des Cognets, Romain Arguel +6 more

The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.

arXiv:2402.18988•Nature Communications•Jul 30, 2024•35 citations

Sagnac interferometry with cold atoms

C. Jentsch, S. Chelkowski, Ernst Maria Rasel +1 more

Summary form only given. Matter wave interferometers have become very promising tools in fundamental physics and metrology. The sensitivities obtained with such atomic quantum sensors compete with classical state-of-the-art devices for acceleration and rotation measurements. Currently, we are setting up a new cold atom Sagnac interferometer (CASI) to realize high precision measurements of rotations with a compact and flexible setup. Using cold atoms the experiment aims to achieve sensitivities down to 2/spl times/10/sup -9/ rad/s/Hz for a compact interferometer as short as 15 cm. Rotations and accelerations will be discriminated by synchronous operation of two counterpropagating ensembles of ultra-cold atoms. We will give an overview about the concept and the parameters of our future interferometer. The results of the characterization of our 2D-MOT, which serves as a brilliant source for our cold atom interferometer, will be presented. The compact design of the sensor will be transportable. Thus, it will permit the comparison with other gyroscopes. CASI will be a first step towards a cold atom space experiment of the second generation.

European Quantum Electronics Conference (EQEC)•Jan 1, 2003•0 citations

Six-Axis Inertial Sensor Using Cold-Atom Interferometry

B. Canuel, Florence Leduc, David Holleville +8 more

We have developed an atom interferometer providing a full inertial base. This device uses two counterpropagating cold-atom clouds that are launched in strongly curved parabolic trajectories. Three single Raman beam pairs, pulsed in time, are successively applied in three orthogonal directions leading to the measurement of the three axis of rotation and acceleration. In this purpose, we introduce a new atom gyroscope using a butterfly geometry. We discuss the present sensitivity and the possible improvements.

arXiv:physics/0604061•Physical Review Letters•Jul 7, 2006•400 citations

Interferometry with Bose-Einstein condensates for inertial sensing

Sven Abend

Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations
Matter-wave interferometry with cold atoms offers a competitive tool for absolute measurements of acceleration and rotation. The sensitivity of atom-interferometric gyroscopes depends on the area enclosed by the interferometer. In this contribution, we present a concept for a rotation sensor, utilizing a multi-loop interferometer geometry to achieve a scalable area while maintaining a compact setup. It enables rotation measurements of a single axis on ground and can be extended to measure rotations along all three spatial axes in microgravity, for potential applications in space missions, Earth observation, and navigation systems.
Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.
The sensitivity of light and matter-wave interferometers to rotations is based on the Sagnac effect and increases with the area enclosed by the interferometer. In the case of light, the latter can be enlarged by forming multiple fibre loops, whereas the equivalent for matter-wave interferometers remains an experimental challenge. We present a concept for a multi-loop atom interferometer with a scalable area formed by light pulses. Our method will offer sensitivities as high as [Formula: see text] rad/s at 1 s in combination with the respective long-term stability as required for Earth rotation monitoring.
The exquisite precision of atom interferometers has sparked the interest of a large community for uses ranging from fundamental physics to geodesy and inertial navigation. However, their implementation for onboard applications is still limited, not least because rotation and acceleration are intertwined in a single phase shift, which makes the extraction of a useful signal more challenging. Moreover, the spatial separation of the wave packets due to rotations leads to a loss of signal. We present an atom interferometer operating over a large range of random angles, rotation rates and accelerations. A model of the expected phase shift allows us to untangle the rotation and acceleration signals. We also implement a real-time compensation system using fiber-optic gyroscopes and a rotating reference mirror to maintain the full contrast of the interferometer. We demonstrate a single-shot sensitivity to acceleration of 24 μg for rotation rates reaching 14° s−1. Cold atoms inertial sensors offer great precision and sensitivity, yet their use in mobile applications has been hindered by the effects of rotations on their measurements. Here, authors demonstrate an atom interferometer operating over a wide range of orientations and rotation rates, thanks to hybridisation with accelerometers and gyroscopes.
Summary form only given. Matter wave interferometers have become very promising tools in fundamental physics and metrology. The sensitivities obtained with such atomic quantum sensors compete with classical state-of-the-art devices for acceleration and rotation measurements. Currently, we are setting up a new cold atom Sagnac interferometer (CASI) to realize high precision measurements of rotations with a compact and flexible setup. Using cold atoms the experiment aims to achieve sensitivities down to 2/spl times/10/sup -9/ rad/s/Hz for a compact interferometer as short as 15 cm. Rotations and accelerations will be discriminated by synchronous operation of two counterpropagating ensembles of ultra-cold atoms. We will give an overview about the concept and the parameters of our future interferometer. The results of the characterization of our 2D-MOT, which serves as a brilliant source for our cold atom interferometer, will be presented. The compact design of the sensor will be transportable. Thus, it will permit the comparison with other gyroscopes. CASI will be a first step towards a cold atom space experiment of the second generation.
We have developed an atom interferometer providing a full inertial base. This device uses two counterpropagating cold-atom clouds that are launched in strongly curved parabolic trajectories. Three single Raman beam pairs, pulsed in time, are successively applied in three orthogonal directions leading to the measurement of the three axis of rotation and acceleration. In this purpose, we introduce a new atom gyroscope using a butterfly geometry. We discuss the present sensitivity and the possible improvements.
Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.