Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Investigation of the measurement dynamics of a flux qubit inductively coupled to a readout dc-SQUID

Peter Groszkowski, Jay Gambetta, Frank K. Wilhelm

Published Mar 21, 2011• 0 citations
OpenAlex

Related papers

DC-SQUID Quantum Non-Demolition Readout of Superconducting Flux Qubits

Kees Harmans

Bulletin of the American Physical Society•Mar 24, 2011•0 citations

Adjusting the dc-SQUID working point by a flux trapping loop for readout of gap-tunable flux qubit

Xiaobo Zhu, Yulin Wu, Hui Deng +5 more

Bulletin of the American Physical Society•Mar 5, 2015•0 citations

Simulation and measurement of a fluxonium qubit inductively coupled to a readout resonator

W. Clarke Smith, Angela Kou, Uri Vool +3 more

Bulletin of the American Physical Society•Mar 6, 2015•0 citations

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•27 citations

A dc SQUID qubit using a dc SQUID readout

R. H. Koch, John R. Kirtley, James R. Rozen +5 more

APS•Mar 1, 2004•0 citations

Realization and Characterization of a Squid Flux Qubit with a Direct Readout Scheme

F. Chiarello, P. Carelli, Maria Gabriella Castellano +6 more

Springer eBooks•May 29, 2006•0 citations
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.