Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Magnetic resonance studies of dressed atoms

Thomas E. Barrett

Published Nov 1, 1997• 0 citations
OpenAlex

Related papers

Magnetic resonance of a two-state atom dressed by a light field

Thomas E. Barrett, Nathan G. Woodard, Gregory P. Lafyatis

We discuss and demonstrate the driving of magnetic resonance transitions between members of a dressed atom doublet. A simple extension of existing dressed atom theory, describes the experimental results reasonably well. We mention low intensity, bare atom interpretations of the experiment and conclude with suggestions for further studies and possible applications.

Physical Review Letters•Jul 20, 1992•9 citations

Magnetic resonance with gas-phase atoms

Michael Mehring, Gerhard Wäckerle

Advances in magnetic and optical resonance•Jan 1, 1997•1 citation

Dressed states and optical resonance

Piers Coleman

•Jan 1, 1982•0 citations

Laser-detected magnetic resonance spectra dressed by a radio-frequency field

Zhi Liang, Xu‐xing Geng, Pan-li Qi +4 more

We theoretically and experimentally investigate the laser-detected magnetic resonance spectra dressed by a radio-frequency magnetic field in F g = 4 of D1 line of cesium atoms. The analytical expression of the transmission spectrum for magnetic resonance dressed by a radio-frequency magnetic field is derived and has substantial agreement with the transmission spectra observed in the experiment. The theoretical prediction of the ratio of the amplitudes of the two sidebands with the detuning is basically consistent with the experimental data, which confirms the validity of the analytical expression. The separation between the two sidebands under resonance shows a highly linear proportion to the amplitude of the dressing field, which may provide a useful scheme for the measurement of radio-frequency magnetic field and magnetic imaging.

Optics Express•Sep 15, 2021•6 citations

DRESSED-ATOM CONTINUUM RESONANCES

Piers Coleman, P. L. Knight

Le Journal de Physique Colloques•Nov 1, 1982•0 citations

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva +1 more

The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.

arXiv:1807.01274•Physical Review Applied•Feb 20, 2019•15 citations
We theoretically and experimentally investigate the laser-detected magnetic resonance spectra dressed by a radio-frequency magnetic field in F g = 4 of D1 line of cesium atoms. The analytical expression of the transmission spectrum for magnetic resonance dressed by a radio-frequency magnetic field is derived and has substantial agreement with the transmission spectra observed in the experiment. The theoretical prediction of the ratio of the amplitudes of the two sidebands with the detuning is basically consistent with the experimental data, which confirms the validity of the analytical expression. The separation between the two sidebands under resonance shows a highly linear proportion to the amplitude of the dressing field, which may provide a useful scheme for the measurement of radio-frequency magnetic field and magnetic imaging.
The low-frequency signal from ultralow-field magnetic resonance imaging (ULF-MRI) setups leads to the use of high-sensitivity noninductive detectors. The simplicity and robustness of optical atomic magnetometers (OAMs) make them excellent candidates to this end, but they suffer from magnetic field inhomogeneities. Appropriate magnetic ``dressing'' of precessing atomic spins can overcome this limitation: Applying a dressing field with opportune inhomogeneity compensates the atomic line broadening induced by the MRI gradient, restoring OAM sensitivity and enabling $i\phantom{\rule{0}{0ex}}n$ $s\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}u$ detection of ULF-MRI signals by optical magnetometry.