IEEE International Conference on Quantum Computing and Engineering (QCE)

Impact of Multi-Photon States on the Calibration of Single-Photon Detectors Using a Portable Bi-Photon Source

Sujeet Pani, Duncan Earl, F. E. Becerra

Published Aug 30, 2025• 0 citations
Publisher

Abstract

We investigate the absolute calibration of single photon detectors (SPDs) based on a portable bi-photon source. We study the impact of multi-photon quantum states from the source on the calibration accuracy and develop a theoretical model to account for this and other effects. Our work provides a path towards practical absolute SPD calibration for future standardized photonic quantum technologies.

DOI
10.1109/qce65121.2025.10401

Related papers

Effects of multi-photon states in the calibration of single-photon detectors based on a portable bi-photon source

S. Pani, Duncan Earl, F. E. Becerra

Single-photon detectors (SPDs) are ubiquitous in many protocols for quantum imaging, sensing, and communications. Many of these protocols critically depend on the precise knowledge of their detection efficiency. A method for the calibration of SPDs based on sources of quantum-correlated photon pairs uses single-photon detection to generate heralded single photons, which can be used as a standard of radiation at the single-photon level. These heralded photons then allow for precise calibration of SPDs in absolute terms. In this work, we investigate the absolute calibration of avalanche photodiodes based on a portable, commercial bi-photon source, and investigate the effects of multi-photon events from the spontaneous parametric down conversion (SPDC) process in these sources. We show that the multi-photon character of the bi-photon source, together with system losses, has a significant impact on the achievable accuracy for the calibration of SPDs. However, modeling the expected photon counting statistics from the squeezed vacuum in the SPDC process allows for accurate estimation of the efficiency of SPDs, assuming that the system losses are known. This study provides essential information for the design and optimization of portable bi-photon sources for their application in on-site calibration of SPDs with high accuracy, without requiring any other reference standard.

arXiv:2412.02566•AVS Quantum Science•Nov 18, 2024•2 citations

Metrology Perspective of Single‐Photon Detectors: Review on Global Calibration Methods

Anish Mahavir Bhargav, Rajib Kumar Rakshit, Samaresh Das +1 more

Abstract The evolution of quantum standards for SI units and funding support from national governments has led to rapid technological developments in the quantum sciences. With this, new and more powerful quantum optical devices that find applications in several fields are obtained. Single‐photon detectors (SPDs) are considered as a critical element in these emerging technologies. A traceability chain for SPD calibration is required to ensure their performance reliability and quality. Different methods and techniques are being developed worldwide for the calibration of SPDs. In this paper, the developments that have occurred globally in SPD calibration and the uncertainty value achieved until now are summarized along with the scope of possible improvement areas.

Advanced Quantum Technologies•Aug 12, 2021•14 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•26 citations

Absolute self-calibration of the quantum efficiency of single-photon detectors

Xihao Chen, Yanhua Zhai, Da Zhang +1 more

Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.

Optics Letters•Jul 25, 2006•21 citations

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations

Twin-photon techniques for photo-detector calibration

G. Brida, Marco Genovese, Marco Gramegna

The aim of this review paper is to enlighten some recent progresses in quantum optical metrology in the part of quantum efficiency measurements of photo-detectors performed with bi-photon states. The intrinsic correlated nature of entangled photons from Spontaneous Parametric Down Conversion phenomenon has opened wide horizons to a new approach for the absolute measurement of photo-detector quantum efficiency, outgoing the requirement for conventional standards of optical radiation; in particular the simultaneous feature of the creation of conjugated photons led to a well known technique of coincidence measurement, deeply understood and implemented for standard uses. On the other hand, based on manipulation of entanglement developed for Quantum Information protocols implementations, a new method has been proposed for quantum efficiency measurement, exploiting polarisation entanglement in addition to energy-momentum and time ones, that is based on conditioned polarisation state manipulation. In this review, after a general discussion on absolute photo-detector calibration, we compare these different methods, in order to give an accurate operational sketch of the absolute quantum efficiency measurement state of the art.

arXiv:quant-ph/0505227•Laser Physics Letters•Nov 15, 2005•61 citations
We investigate the absolute calibration of single photon detectors (SPDs) based on a portable bi-photon source. We study the impact of multi-photon quantum states from the source on the calibration accuracy and develop a theoretical model to account for this and other effects. Our work provides a path towards practical absolute SPD calibration for future standardized photonic quantum technologies.
Single-photon detectors (SPDs) are ubiquitous in many protocols for quantum imaging, sensing, and communications. Many of these protocols critically depend on the precise knowledge of their detection efficiency. A method for the calibration of SPDs based on sources of quantum-correlated photon pairs uses single-photon detection to generate heralded single photons, which can be used as a standard of radiation at the single-photon level. These heralded photons then allow for precise calibration of SPDs in absolute terms. In this work, we investigate the absolute calibration of avalanche photodiodes based on a portable, commercial bi-photon source, and investigate the effects of multi-photon events from the spontaneous parametric down conversion (SPDC) process in these sources. We show that the multi-photon character of the bi-photon source, together with system losses, has a significant impact on the achievable accuracy for the calibration of SPDs. However, modeling the expected photon counting statistics from the squeezed vacuum in the SPDC process allows for accurate estimation of the efficiency of SPDs, assuming that the system losses are known. This study provides essential information for the design and optimization of portable bi-photon sources for their application in on-site calibration of SPDs with high accuracy, without requiring any other reference standard.
Abstract The evolution of quantum standards for SI units and funding support from national governments has led to rapid technological developments in the quantum sciences. With this, new and more powerful quantum optical devices that find applications in several fields are obtained. Single‐photon detectors (SPDs) are considered as a critical element in these emerging technologies. A traceability chain for SPD calibration is required to ensure their performance reliability and quality. Different methods and techniques are being developed worldwide for the calibration of SPDs. In this paper, the developments that have occurred globally in SPD calibration and the uncertainty value achieved until now are summarized along with the scope of possible improvement areas.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
The aim of this review paper is to enlighten some recent progresses in quantum optical metrology in the part of quantum efficiency measurements of photo-detectors performed with bi-photon states. The intrinsic correlated nature of entangled photons from Spontaneous Parametric Down Conversion phenomenon has opened wide horizons to a new approach for the absolute measurement of photo-detector quantum efficiency, outgoing the requirement for conventional standards of optical radiation; in particular the simultaneous feature of the creation of conjugated photons led to a well known technique of coincidence measurement, deeply understood and implemented for standard uses. On the other hand, based on manipulation of entanglement developed for Quantum Information protocols implementations, a new method has been proposed for quantum efficiency measurement, exploiting polarisation entanglement in addition to energy-momentum and time ones, that is based on conditioned polarisation state manipulation. In this review, after a general discussion on absolute photo-detector calibration, we compare these different methods, in order to give an accurate operational sketch of the absolute quantum efficiency measurement state of the art.