Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Diamond and Related Materials

Vibronic property of NV− and NV0 centers in diamond and the thermal behavior of zero-phonon lines

Z.W. Zheng, Xiaona Li, C.X. Li, Nan Zhou, Cheng Ma, Q.Y. Zhang, Ce Zhang, Zao Yi

Published Nov 17, 2025• 3 citations
Publisher
DOI
10.1016/j.diamond.2025.113081

Related papers

Thermal behaviors of the sharp zero–phonon luminescence lines of NV center in diamond

Yitian Bao, Shijie Xu, Zeyang Ren +4 more

Journal of Luminescence•Mar 27, 2021•11 citations

Zeeman effect on the zero-phonon line of the NV center in synthetic diamond

H. Hanzawa, H. Nishikori, Yosio Nisida +4 more

Physica B Condensed Matter•Feb 1, 1993•14 citations

Laser spectroscopic characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond

Shova D. Subedi, Vladimir Fedorov, Jeremy M. Peppers +4 more

We report on the spectroscopic and laser characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond. Spectroscopic properties such as absorption and emission spectra as well as kinetics were studied, and parameters such as cross-sections and lifetimes were estimated. A vibronic band of NV0 with zero phonon line (ZPL) at 575 nm was detected under 532 nm pulsed excitation due to the photoionization of NV−. Transmission of 532 nm pump pulses saturate around ∼10%, which is much smaller than the theoretical level. Δk/k0 kinetics revealed slow recovery of NV− centers after photoionization under 532 nm pumping, which involved different relaxation channels depending on the probe beam wavelengths. Localization of the electrons in the metastable state of NV0 centers resulted in higher saturated transmission of 632 nm pump.

Optical Materials Express•Apr 5, 2019•73 citations

Stimulated emission cross sections and temperature‐dependent spectral shifts of neutral nitrogen‐vacancy centers in diamonds

Teng‐I Yang, Terumitsu Azuma, Yu‐Wen Huang +3 more

Abstract The neutral nitrogen‐vacancy (NV0) defects in diamond are photostable color centers, suitable for a wide range of applications in science and engineering. However, the photophysical properties of the centers have not yet been fully characterized. This work measured the stimulated emission cross sections of NV0 in a single‐crystal diamond by two‐photon excitation of its matrix at 344 nm. From the measured photoluminescence spectrum and the fluorescence lifetime of 20 ± 1 ns, we determined a peak stimulated emission cross section of 1.43 ± 0.07 × 10−17 cm2 at 650 nm for the NV0 centers. In addition, we have also examined the thermal shifts of the zero‐phonon line of NV0 centers in nanoscale diamonds (~100 nm in diameter) over the temperature range of 30–120°C. A temperature measurement sensitivity of 0.2 K·Hz−1/2 was achieved, which is about two‐fold better than that of NV−, despite that the fluorescence intensity of NV0 is about six‐fold lower than that of NV− in the same nanoparticles. The result is attributed to the smaller electron–phonon coupling strength of the neutral center, compared with its negatively charged counterpart.

Journal of the Chinese Chemical Society•Dec 19, 2022•9 citations

Investigation of zero-phonon line characteristics in ensemble nitrogen-vacancy centers at 1.6 K–300 K

Zhenrong Zhang, Huan Fei Wen, Ziheng Gao +8 more

The ensemble of nitrogen-vacancy (NV) centers is widely used in quantum information transmission, high-precision magnetic field, and temperature sensing due to their advantages of long-lived state and the ability to be pumped by optical cycling. In this study, we investigate the zero-phonon line behavior of the two charge states of NV centers by measuring the photoluminescence of the NV center at 1.6 K-300 K. The results demonstrate a positional redshift, an increase in line width, and a decrease in fluorescence intensity for the ZPL of NV0 and NV- as the temperature increased. In the range of 10 K to 140 K, the peak shift with high concentrations of NV- revealed an anomaly of bandgap reforming. The peak position undergoes a blueshift and then a redshift as temperature increases. Furthermore, the transformation between NV0 and NV- with temperature changes has been obtained in diamonds with different nitrogen concentrations. This study explored the ZPL characteristics of NV centers in various temperatures, and the findings are significant for the development of high-resolution temperature sensing and high-precision magnetic field sensing in ensemble NV centers.

Optics Express•Apr 17, 2024•2 citations

Effect of phonons on the optical properties of color centers in diamond

Ariel Norambuena Zamorano

•Mar 7, 2018•0 citations
We report on the spectroscopic and laser characterization of negatively charged nitrogen-vacancy (NV−) centers in diamond. Spectroscopic properties such as absorption and emission spectra as well as kinetics were studied, and parameters such as cross-sections and lifetimes were estimated. A vibronic band of NV0 with zero phonon line (ZPL) at 575 nm was detected under 532 nm pulsed excitation due to the photoionization of NV−. Transmission of 532 nm pump pulses saturate around ∼10%, which is much smaller than the theoretical level. Δk/k0 kinetics revealed slow recovery of NV− centers after photoionization under 532 nm pumping, which involved different relaxation channels depending on the probe beam wavelengths. Localization of the electrons in the metastable state of NV0 centers resulted in higher saturated transmission of 632 nm pump.
Abstract The neutral nitrogen‐vacancy (NV0) defects in diamond are photostable color centers, suitable for a wide range of applications in science and engineering. However, the photophysical properties of the centers have not yet been fully characterized. This work measured the stimulated emission cross sections of NV0 in a single‐crystal diamond by two‐photon excitation of its matrix at 344 nm. From the measured photoluminescence spectrum and the fluorescence lifetime of 20 ± 1 ns, we determined a peak stimulated emission cross section of 1.43 ± 0.07 × 10−17 cm2 at 650 nm for the NV0 centers. In addition, we have also examined the thermal shifts of the zero‐phonon line of NV0 centers in nanoscale diamonds (~100 nm in diameter) over the temperature range of 30–120°C. A temperature measurement sensitivity of 0.2 K·Hz−1/2 was achieved, which is about two‐fold better than that of NV−, despite that the fluorescence intensity of NV0 is about six‐fold lower than that of NV− in the same nanoparticles. The result is attributed to the smaller electron–phonon coupling strength of the neutral center, compared with its negatively charged counterpart.
The ensemble of nitrogen-vacancy (NV) centers is widely used in quantum information transmission, high-precision magnetic field, and temperature sensing due to their advantages of long-lived state and the ability to be pumped by optical cycling. In this study, we investigate the zero-phonon line behavior of the two charge states of NV centers by measuring the photoluminescence of the NV center at 1.6 K-300 K. The results demonstrate a positional redshift, an increase in line width, and a decrease in fluorescence intensity for the ZPL of NV0 and NV- as the temperature increased. In the range of 10 K to 140 K, the peak shift with high concentrations of NV- revealed an anomaly of bandgap reforming. The peak position undergoes a blueshift and then a redshift as temperature increases. Furthermore, the transformation between NV0 and NV- with temperature changes has been obtained in diamonds with different nitrogen concentrations. This study explored the ZPL characteristics of NV centers in various temperatures, and the findings are significant for the development of high-resolution temperature sensing and high-precision magnetic field sensing in ensemble NV centers.