Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Transparent Optical Networks

Optical quantum frequency standard bases for MADQuantum-CM communication network

Ismael Caballero, Adriana Palos, Daniel de Mecado, Yolanda Álvarez, David Peral, Javier Díaz de Aguilar

Published Jul 1, 2025• 1 citation
Publisher

Abstract

This paper presents the development of an optical frequency standard based on trapped ions within the MADQuantum-CM project, aimed at establishing a quantum communications network in the Community of Madrid. Centro Español de Metrología (CEM) has a key role as a node in this network, contributing to its synchronization through a high-precision frequency reference.The optical frequency standard developed at CEM utilizes the 4 S1/2↔ 3 D5/2transition in40Ca+ions at 729 nm. This system comprises an ion trapping setup using a Paul trap, laser cooling techniques, and an ultra-stable laser to achieve a linewidth in the order of 1 Hz. Additionally, a frequency comb is employed to ensure precise optical frequency measurements.By integrating this frequency standard into the quantum network, highly stable and accurate time references will be able to be distributed, which is essential for quantum communication protocols.

DOI
10.1109/icton67126.2025.11125345

Related papers

Towards the Development of an Optical Quantum Frequency Standard Feasible for a Medium-Size NMI

Adriana Palos, Ismael Caballero, Daniel de Mercado Raposo +3 more

Centro Español de Metrología (CEM) is developing a quantum frequency standard based on trapped calcium ions, marking its entry into the landscape of the second quantum revolution. Optical frequency standards offer unprecedented precision by referencing atomic transitions that are fundamentally stable and immune to environmental drift. However, the challenge of developing such a system from scratch is unaffordable for a medium-sized National Metrology Institute (NMI), which seems to limit the ability of an institute such as CEM to contribute to this field of research. To overcome this, CEM has adopted a hybrid strategy, combining commercially available components with custom integration to accelerate deployment. This paper defines and implements an architecture adapted to the constraints of a medium-size NMI, where the main contribution is the systematic design, selection, and interconnection of the subsystems required to realize this standard. The rationale behind the system design is presented, detailing the integration of key elements for ion trapping, laser stabilization, frequency measurement, and system control. Current progress, ongoing developments, and future research directions are outlined, establishing the foundation for spectroscopic measurements and uncertainty evaluation. The project represents a strategic step toward strengthening national capabilities in quantum metrology for a medium-sized NMI.

Metrology•Dec 8, 2025•1 citation

Progress Toward an Optical Frequency Standard Based on a Single Indium Ion

Y. H. Wang, T. Liu, Alois Stejskal +7 more

We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•6 citations

Optical frequency standard based on a single 40Ca+

Kelin Gao

Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.

Chinese Science Bulletin•Mar 1, 2013•9 citations

Photon frequency convertor for quantum networks

Victor Krutyansiy, Martin Meraner, Josef Schupp +3 more

Quantum network consisting of separate nodes processing information and linked by quantum channels is a promising and widely investigated general architecture for scalable and distributed quantum computing [1]. The most feasible proposals for realisation of such a network involve matter-based nodes (e.g. trapped atoms or ions or solid-state systems) communicating by photons [2]. This approach combines advantages of long-living and precisely manipulated systems for nodes with fast and convenient for long distance information transfer ones. Implementation of such a scheme opens up a lot of research challenges where establishing a reliable channel for quantum state transfer between two nodes by photons is essential, once the nodes are operating. It would by particularly convenient to have a standard channel that can different systems be talking to and the telecom band photons are good candidates for that because of well-established optical fiber infrastructure. In our work we implement a single photon frequency conversion to telecom band so that quantum systems with different emitting frequencies could be used in such a network. This approach also permits to minimize the losses and increase distances to 10s-kilometre range by exploiting the lowest attenuation band in fibers. The work is aimed in particular on developing device capable of converting photons produced by P3/2-D5/2transition in40Ca+ ion that corresponds to 854.2 nm wavelength as a promising candidate for the network nod.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•1 citation

Indium single ion optical frequency standard

T. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 13, 2002•3 citations

Indium single-ion optical frequency standard

Thomas P. Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 3, 2001•0 citations
This paper presents the development of an optical frequency standard based on trapped ions within the MADQuantum-CM project, aimed at establishing a quantum communications network in the Community of Madrid. Centro Español de Metrología (CEM) has a key role as a node in this network, contributing to its synchronization through a high-precision frequency reference.The optical frequency standard developed at CEM utilizes the 4 S1/2↔ 3 D5/2transition in40Ca+ions at 729 nm. This system comprises an ion trapping setup using a Paul trap, laser cooling techniques, and an ultra-stable laser to achieve a linewidth in the order of 1 Hz. Additionally, a frequency comb is employed to ensure precise optical frequency measurements.By integrating this frequency standard into the quantum network, highly stable and accurate time references will be able to be distributed, which is essential for quantum communication protocols.
Centro Español de Metrología (CEM) is developing a quantum frequency standard based on trapped calcium ions, marking its entry into the landscape of the second quantum revolution. Optical frequency standards offer unprecedented precision by referencing atomic transitions that are fundamentally stable and immune to environmental drift. However, the challenge of developing such a system from scratch is unaffordable for a medium-sized National Metrology Institute (NMI), which seems to limit the ability of an institute such as CEM to contribute to this field of research. To overcome this, CEM has adopted a hybrid strategy, combining commercially available components with custom integration to accelerate deployment. This paper defines and implements an architecture adapted to the constraints of a medium-size NMI, where the main contribution is the systematic design, selection, and interconnection of the subsystems required to realize this standard. The rationale behind the system design is presented, detailing the integration of key elements for ion trapping, laser stabilization, frequency measurement, and system control. Current progress, ongoing developments, and future research directions are outlined, establishing the foundation for spectroscopic measurements and uncertainty evaluation. The project represents a strategic step toward strengthening national capabilities in quantum metrology for a medium-sized NMI.
We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.
Research on the development of the optical frequency standard based on trapped and cold 40 Ca + with the 4s 2 S 1/2 -3d 2 D 5/2 clock transition at 729 nm is reported. A single calcium ion was trapped and laser cooled in the Paul trap and stay in trap for more than 15 days. The linewidth of a 729 nm laser was reduced to less than 10 Hz by locking to a cavity for longer than 50 hours uninterruptedly. The overall systematic uncertainty of the clock transition has been characterized to be better than 6.5×10 −16 . The absolute frequency of the clock transition was measured at 10 −15 level using an optical frequency comb referenced to a Hydrogen maser, which was calibrated to the SI second through the global positioning system (GPS). The frequency value was 411042129776393.0(1.6) Hz after the correction of the systematic shifts.
Quantum network consisting of separate nodes processing information and linked by quantum channels is a promising and widely investigated general architecture for scalable and distributed quantum computing [1]. The most feasible proposals for realisation of such a network involve matter-based nodes (e.g. trapped atoms or ions or solid-state systems) communicating by photons [2]. This approach combines advantages of long-living and precisely manipulated systems for nodes with fast and convenient for long distance information transfer ones. Implementation of such a scheme opens up a lot of research challenges where establishing a reliable channel for quantum state transfer between two nodes by photons is essential, once the nodes are operating. It would by particularly convenient to have a standard channel that can different systems be talking to and the telecom band photons are good candidates for that because of well-established optical fiber infrastructure. In our work we implement a single photon frequency conversion to telecom band so that quantum systems with different emitting frequencies could be used in such a network. This approach also permits to minimize the losses and increase distances to 10s-kilometre range by exploiting the lowest attenuation band in fibers. The work is aimed in particular on developing device capable of converting photons produced by P3/2-D5/2transition in40Ca+ ion that corresponds to 854.2 nm wavelength as a promising candidate for the network nod.
A single laser cooled ion in a radiofrequency trap can serve as the basis for a highly stable optical frequency standard. We present recent results of our work on single indium ions, using the /sup 1/S/sub 0/ to /sup 3/P/sub 0/ transition at 236.5 nm wave-length as the clock transition. This resonance has a linewidth of only 0.82 Hz where systematic shifts should be controllable on the mHz level. A single In/sup +/ ion is stored in a miniature Paul-Straubel trap and laser cooled to a temperature of about 100 /spl mu/K. The clock transition is excited using a frequency quadrupled Nd:YAG laser. A fractional resolution of 1.3/spl middot/10/sup -13/ has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute frequency of the clock transition clock transition has been measured with an uncertainty of 2/spl middot/10/sup -13/ using a frequency chain and a methane-stabilized HeNe laser as a reference, that was calibrated with a cesium clock.
Single laser-cooled ions in radiofrequency traps can serve as the basis for highly stable optical frequency standards. Here we present recent results on In+, using the 1S0 yields 3P0 line at 236.5 nm wavelength as the clock transition. This resonance has a natural linewidth of only 0.82 Hz and systematic shifts should be controllable at the mHz level. A single indium ion is stored in a miniature Paul- Straubel trap and laser cooled to a temperature of about 100 (mu) K. The clock transition is excited using a frequency quadrupled 946 nm Nd:YAG laser. A fractional resolution of 1.3 (DOT) 10-13 has been achieved so far (linewidth of 170 Hz at 1267 THz). The absolute optical frequency of the clock transition has been measured with an uncertainty being less than 3 (DOT) 10-13 using a frequency chain and a methane-stabilized HeNe laser that was calibrated with a cesium clock.