Frontiers in Physics

Frequency shift properties of a calcium beam optical clock

Yu Chen, Yabei Su, Jiyang Ma, Jing Peng, Ming Ma, Xiaobo Xue, Shengkang Zhang

Published May 16, 2025• 0 citations
Publisher

Abstract

The optical frequency transitions with long-lifetime spin triplet states produced by the two valence electrons in the outermost layer of alkaline earth atoms make calcium atom a promising quantum frequency reference. Electron-shelving detection improves the signal-to-noise ratio of the clock transition spectrum, enabling a calcium atomic beam optical frequency standard. This scheme employs the 1S0-1P1 transition at 423 nm to detect the 1S0-3P1 transition at 657 nm, emphasizing the importance of 423 nm laser stability. While the performance of these clocks is well-studied, research on the atomic beam itself is limited. This study investigates frequency shifts in neutral calcium atoms’ 1S0-1P1 transition at 423 nm and their 1S0-3P1 transition at 657 nm. We measure the frequency shift caused by temperature, laser power, and laser alignment, providing insights to optimize the design of the calcium beam’s physical apparatus.

DOI
10.3389/fphy.2025.1597737

Related papers

Frequency Shift Properties of 1S0-1P1 Transition of a Calcium Beam Optical Clock

Yu Chen, Yabei Su, Lei Han +3 more

The narrow linewidth of1S0-3P1657 nm clock transition makes it a promising quantum frequency reference. In this experiment, the fast1S0-1P1423 nm transition is used to detect the narrow1S0-3P1657 nm clock transition. Therefore, the frequency stability of the 423 nm laser determines the performance of the optical frequency standard. Here we investigate the frequency shift properties of the neutral calcium atoms'1S0-1P1transition at 423 nm. We measure the frequency shift caused by temperature, laser power, and laser beam pointing.

European Frequency and Time Forum•Jun 25, 2024•0 citations

Frequency stabilization of 423 nm laser for calcium-beam optical frequency standard

Shengnan Zhang, Xiaogang Zhang, Haosen Shang +2 more

The Ca beam optical frequency standard has the potential to be small optical clock like small Cs beam clock in microwave regime. For improving the signal-to-noise ratio of the clock transition spectroscopy, the electron shelving detection, which uses the fast1S0-1P1423nm transition to detect the narrow1S0-3P1657nm clock transition, was applied for Ca beam optical frequency standard. Therefore the frequency stability of 423 nm laser to some extent determines the performance of the optical frequency standard. In this paper, we stabilize the 423 nm laser frequency to Ca beam signal with side-band locking technique and estimate the preliminary stability of 423 nm laser which is 1.4×10-11at 1 s and 2×10-12at 100 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Application of Electron-Shelving Detection via 423 nm Transition in Calcium-Beam Optical Frequency Standard

Huang Kai-Kai, Zhang Jian-Wei, Deshui Yu +3 more

A new scheme of small compact optical frequency standard based on thermal calcium beam with application of 423 nm shelving detection and sharp-angle velocity selection detection is proposed. Combining these presented techniques, we conclude that a small compact optical frequency standard based on thermal calcium beam will outperform the commercial caesium-beam microwave clock, like the 5071 Cs clock (from HP to Agilent, now Symmetricom company), both in accuracy and stability.

Chinese Physics Letters•Nov 29, 2006•26 citations

Understanding atomic interactions in an optical lattice clock and using them to study many-body physics

Michael Bishof

Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.

•Jan 1, 2014•0 citations

A small calcium beam optical frequency standard with fully-sealed vacuum tube

Haosen Shang, Xiaogang Zhang, Shengnan Zhang +2 more

In this paper a small Calcium beam optical frequency standard utilizing fully-sealed Calcium beam vacuum tube owning smaller size compared with vacuum system with flanges is demonstrated. Adopting the electron shelving detection method, we detect the clock transition 657 nm saturation absorbing spectroscopy whose linewidth is 500 kHz. The instability of this small optical frequency standard is 6.8×10-14at 1 second and 1.8×10-15after 1000 seconds of averaging by comparing with another small Calcium beam optical frequency standard whose reported instability is 3.0×10-14at 1 second. The optical part of the whole system is specially designed for robustness and miniaturization.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Blue laser for precision spectroscopy: toward optical frequency standard referenced to laser cooled calcium atoms

Vera Grishina

Optical frequency standards with the reference to a narrow electronic transition of a laser-cooled collection of neutral atomic particles are becoming essential tools of research in modern precision physics experiments. In the core of a building block of an optical frequency standard is the optical continuous wave laser that has a good spectral purity of the emitted light. Such a stable optical oscillator is highly desirable in high resolution spectroscopy, if it emits in a good quality beam at a short visible wavelength. This Master thesis explores efficient techniques for building such an optical frequency source intended for use in the cooling and trapping of Calcium atoms scheme. The strong dipole transition at the blue wavelength in the atomic Calcium is needed to reduce the kinetic energy of atoms by nearly six orders of magnitude. A further reduction in the thermal energy of the laser cooled atoms is required to locate with ultra-high precision the 400 Hz narrow clock transition of the stable 40Ca isotope. The experimental methods that achieve this and approach sub-microkelvin temperature of the laser cooled bosonic isotopes of alkaline earths are inspected. The blue laser with a uniform intensity distribution in the beam is useful to maintain the trapped number of cold atoms during these experiments. The spectroscopic properties of the relative transitions in Calcium atom are also reviewed following relevant publications in the area. The constructed blue laser can be used as a primary wavelength source in the lasers network for cooling and trapping of Calcium atoms. These experiments will constitute part of the project to build an optical atom clock referenced to 40Ca narrow linewidth transition. The blue laser is constructed by generating second harmonic in a Potassium Niobate crystal, which is temperature controlled to use a type-I noncritical phase-matching of the optical nonlinear process. The power of the intracavity-generated second harmonic depends on the resonance properties of the optical resonator where this nonlinear crystal is placed. The study is aimed at characterising the designed optical resonator and the experimental parameters that describe it. The formula is derived that relates the resonance power enhancement coefficient with finesse and the power coupling contrast of a passive optical cavity. The obtained relationship is verfied during the experiments. The produced efficiency of the intracavity second harmonic generation is approx. 0.0023 mWblue/(mWred)2. The research work also examines the noise characteristics of the infrared diode laser that is used as a pump source for the intracavity generated second harmonic and determines the spectroscopic precision of the produced blue light. The frequency locking experiment is analysed using the unbalanced scheme of the polarisation stabilisation technique. The designed optical buildup cavity became a part of the unbalanced frequency discriminator in such a scheme. The results demonstrate high gain of frequency noise suppression of the stabilised laser. The unbalanced arrangement of the H}ansch-Couillaud technique has been possible due to a very low amplitude noise of semiconductor lasers.

•Jan 1, 2008•0 citations
The optical frequency transitions with long-lifetime spin triplet states produced by the two valence electrons in the outermost layer of alkaline earth atoms make calcium atom a promising quantum frequency reference. Electron-shelving detection improves the signal-to-noise ratio of the clock transition spectrum, enabling a calcium atomic beam optical frequency standard. This scheme employs the 1S0-1P1 transition at 423 nm to detect the 1S0-3P1 transition at 657 nm, emphasizing the importance of 423 nm laser stability. While the performance of these clocks is well-studied, research on the atomic beam itself is limited. This study investigates frequency shifts in neutral calcium atoms’ 1S0-1P1 transition at 423 nm and their 1S0-3P1 transition at 657 nm. We measure the frequency shift caused by temperature, laser power, and laser alignment, providing insights to optimize the design of the calcium beam’s physical apparatus.
The narrow linewidth of1S0-3P1657 nm clock transition makes it a promising quantum frequency reference. In this experiment, the fast1S0-1P1423 nm transition is used to detect the narrow1S0-3P1657 nm clock transition. Therefore, the frequency stability of the 423 nm laser determines the performance of the optical frequency standard. Here we investigate the frequency shift properties of the neutral calcium atoms'1S0-1P1transition at 423 nm. We measure the frequency shift caused by temperature, laser power, and laser beam pointing.
The Ca beam optical frequency standard has the potential to be small optical clock like small Cs beam clock in microwave regime. For improving the signal-to-noise ratio of the clock transition spectroscopy, the electron shelving detection, which uses the fast1S0-1P1423nm transition to detect the narrow1S0-3P1657nm clock transition, was applied for Ca beam optical frequency standard. Therefore the frequency stability of 423 nm laser to some extent determines the performance of the optical frequency standard. In this paper, we stabilize the 423 nm laser frequency to Ca beam signal with side-band locking technique and estimate the preliminary stability of 423 nm laser which is 1.4×10-11at 1 s and 2×10-12at 100 s.
Strontium optical lattice clocks at JILA recently demonstrated record-high accuracy and stability. These advances were enabled by an ultrastable laser with fractional frequency stability of 1x10-16 at 1 second. This laser allows us to study systematic shifts of the 1S0 to 3P0 clock transition with unprecedented precision. Density-dependent frequency shifts represent an unavoidable perturbation for clocks based on many atoms. Our studies of atomic interactions in an optical lattice clock system uncover the nature of these interactions and reveal important many-body atomic correlation effects in this open quantum system. By extending our measurements to all ten nuclear-spin sublevels of the clock states, we observe the first direct evidence of SU(N) symmetric interactions in alkaline earth(-like) atoms. Using the techniques we developed in these studies, we also demonstrate a novel technique for measuring the frequency noise spectrum of an ultrastable laser. We discuss designs for the future direction of our experiment which will place 87Sr atoms within a high finesse cavity that is resonant on the 1S0 to 3P1 transition. We will use this system to study collective effects in cavity quantum electrodynamics. Most notably, strong atom-cavity coupling can enhance the spectroscopic sensitivity of our clock by creating spin-squeezed states via quantum non-demolition measurements. As a precursor to future work studying cavity-mediated collective behavior, we use the unique atomic structure of 88Sr to investigate free-space retarded dipolar coupling in an optically thick sample of atoms.
In this paper a small Calcium beam optical frequency standard utilizing fully-sealed Calcium beam vacuum tube owning smaller size compared with vacuum system with flanges is demonstrated. Adopting the electron shelving detection method, we detect the clock transition 657 nm saturation absorbing spectroscopy whose linewidth is 500 kHz. The instability of this small optical frequency standard is 6.8×10-14at 1 second and 1.8×10-15after 1000 seconds of averaging by comparing with another small Calcium beam optical frequency standard whose reported instability is 3.0×10-14at 1 second. The optical part of the whole system is specially designed for robustness and miniaturization.
Optical frequency standards with the reference to a narrow electronic transition of a laser-cooled collection of neutral atomic particles are becoming essential tools of research in modern precision physics experiments. In the core of a building block of an optical frequency standard is the optical continuous wave laser that has a good spectral purity of the emitted light. Such a stable optical oscillator is highly desirable in high resolution spectroscopy, if it emits in a good quality beam at a short visible wavelength. This Master thesis explores efficient techniques for building such an optical frequency source intended for use in the cooling and trapping of Calcium atoms scheme. The strong dipole transition at the blue wavelength in the atomic Calcium is needed to reduce the kinetic energy of atoms by nearly six orders of magnitude. A further reduction in the thermal energy of the laser cooled atoms is required to locate with ultra-high precision the 400 Hz narrow clock transition of the stable 40Ca isotope. The experimental methods that achieve this and approach sub-microkelvin temperature of the laser cooled bosonic isotopes of alkaline earths are inspected. The blue laser with a uniform intensity distribution in the beam is useful to maintain the trapped number of cold atoms during these experiments. The spectroscopic properties of the relative transitions in Calcium atom are also reviewed following relevant publications in the area. The constructed blue laser can be used as a primary wavelength source in the lasers network for cooling and trapping of Calcium atoms. These experiments will constitute part of the project to build an optical atom clock referenced to 40Ca narrow linewidth transition. The blue laser is constructed by generating second harmonic in a Potassium Niobate crystal, which is temperature controlled to use a type-I noncritical phase-matching of the optical nonlinear process. The power of the intracavity-generated second harmonic depends on the resonance properties of the optical resonator where this nonlinear crystal is placed. The study is aimed at characterising the designed optical resonator and the experimental parameters that describe it. The formula is derived that relates the resonance power enhancement coefficient with finesse and the power coupling contrast of a passive optical cavity. The obtained relationship is verfied during the experiments. The produced efficiency of the intracavity second harmonic generation is approx. 0.0023 mWblue/(mWred)2. The research work also examines the noise characteristics of the infrared diode laser that is used as a pump source for the intracavity generated second harmonic and determines the spectroscopic precision of the produced blue light. The frequency locking experiment is analysed using the unbalanced scheme of the polarisation stabilisation technique. The designed optical buildup cavity became a part of the unbalanced frequency discriminator in such a scheme. The results demonstrate high gain of frequency noise suppression of the stabilised laser. The unbalanced arrangement of the H}ansch-Couillaud technique has been possible due to a very low amplitude noise of semiconductor lasers.