The initial state of atom clouds significantly influences the performance of cold-atom inertial sensors, particularly for atom gravity gradiometers (AGGs), where the consistency of the initial state of two atom clouds greatly affects measurement performance. By analyzing the mechanism of polarization gradient cooling (PGC), we investigate its effect on the initial velocity consistency of atomic clouds. In the course of this study, we compare different PGC models and identify a model that has the least influence on initial velocity consistency. Based on this model, the velocity difference between the two atom clouds is modulated by various experimental parameters, such as the laser power attenuation time, which ranges from 1 to 6 s with the laser detuning of −88 MHz. The results indicate that the gravity gradient increases by approximately 66.13 E (1 E = 10 −9 s −2 ) for each millimeter per second increase in the velocity difference between the two atomic clouds. The study finds that this velocity difference introduces gravity gradient measurement errors through the two-photon light shift effect. This observation is in excellent agreement with our theoretical calculations. Our study elucidates the mechanism by which the initial velocity difference of atom clouds calibrates instrument measurement errors in AGGs and provides a reference for further enhancing the measurement accuracy of such sensors.
The initial state of atom clouds significantly influences the performance of cold-atom inertial sensors, particularly for atom gravity gradiometers (AGGs), where the consistency of the initial state of two atom clouds greatly affects measurement performance. By analyzing the mechanism of polarization gradient cooling (PGC), we investigate its effect on the initial velocity consistency of atomic clouds. In the course of this study, we compare different PGC models and identify a model that has the least influence on initial velocity consistency. Based on this model, the velocity difference between the two atom clouds is modulated by various experimental parameters, such as the laser power attenuation time, which ranges from 1 to 6 s with the laser detuning of −88 MHz. The results indicate that the gravity gradient increases by approximately 66.13 E (1 E = 10 −9 s −2 ) for each millimeter per second increase in the velocity difference between the two atomic clouds. The study finds that this velocity difference introduces gravity gradient measurement errors through the two-photon light shift effect. This observation is in excellent agreement with our theoretical calculations. Our study elucidates the mechanism by which the initial velocity difference of atom clouds calibrates instrument measurement errors in AGGs and provides a reference for further enhancing the measurement accuracy of such sensors.
One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.
We investigated the Raman-pulse-duration effect in a gravity gradiometer with two atom interferometers. Since the two atom clouds in the gradiometer experience different gravitational fields, it is hard to compensate for the Doppler shifts of the two clouds simultaneously by chirping the frequency of a common Raman laser. This leads to an appreciable phase shift. The magnitude of the phase shift relative to the differential phase shift of the two interferometers is in an order of $\ensuremath{\tau}/T$, and cannot be neglected in the precision measurements such as measuring the gravity gradient and the Newtonian gravitational constant.
A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.
The technology of electro-optic modulation is one of the several methods of generating the Raman beams. The experimental system based on this method is simple and much easier to implement, and the environmental adaptability is strong as well. However, this kind of modulation technology will produce additional laser lines, which may affect the measurement accuracy of cold atom gravimeter. Based on a homemade transportable cold atom gravimeter, the influence of Raman sideband effect on the accuracy of cold atom gravimeter is investigated in this paper. We analyze in detail the relationship between Raman sideband effect and some experimental parameters, such as the height of Raman retro-reflection mirror, the time of free fall of the atoms, the detuning of Raman laser, etc. It is found that those parameters have a dominant influence on the measured gravity resulting from Raman sideband effect. Besides, it is also found that the gravity measurements will be sensitive again to some experimental parameters in the case of Raman sideband effect while these parameters are usually insensitive in case of laser system without sideband effect. Finally, we investigate the relationship between Raman sideband effect and Raman detuning, and presente a method of evaluating the gravity induced by Raman sideband effect. The experimental results in this paper can provide a reference for reducing the influence of Raman sideband effect on the accuracy evaluation of cold atomic gravimeter.
Atom interferometer gravity gradient measurement instrument has a very high measuring resolution when atomic interference of gravity gradient experiments, the first to obtain two atoms using a magneto-optical trap, after throwing or whereabouts and realization of double groups of interference in operation, during the process of the experiment on two-atom fountain behind the speed of synchronization is the prerequisite of implementation measure, In this paper, an experimental method for adjusting the up-throw velocity of a two-atom fountain is introduced. The uniformity of up-throw velocity of a two-atom fountain is achieved by utilizing an optical beam expanding tube of a cooling laser and a geomagnetic compensation coil, which can enhance the detection noise of the atomic interference gravity gradiometer.
In an ideal test of the equivalence principle, the test masses fall in a common inertial frame. A real experiment is affected by gravity gradients, which introduce systematic errors by coupling to initial kinematic differences between the test masses. Here we demonstrate a method that reduces the sensitivity of a dual-species atom interferometer to initial kinematics by using a frequency shift of the mirror pulse to create an effective inertial frame for both atomic species. Using this method, we suppress the gravity-gradient-induced dependence of the differential phase on initial kinematic differences by 2 orders of magnitude and precisely measure these differences. We realize a relative precision of Δg/g≈6×10^{-11} per shot, which improves on the best previous result for a dual-species atom interferometer by more than 3 orders of magnitude. By reducing gravity gradient systematic errors to one part in 10^{13}, these results pave the way for an atomic test of the equivalence principle at an accuracy comparable with state-of-the-art classical tests.