Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Spectroscopy and imaging using entangled photon pairs and a time-of-arrival camera

Jeff S. Lundeen

Published Mar 19, 2025• 0 citations
Publisher
DOI
10.1117/12.3053455

Related papers

Image-plane detection of spatially entangled photon pairs with a CMOS camera

David McFadden, Rainer Heintzmann

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Imaging the Joint Probability Distribution of Spatially Entangled Photon Pairs with a Camera

Matthew C. Reichert, Hugo Defienne, Jason W. Fleischer

We present massively parallel coincidence counting of entangled photon pairs by measuring coincidences between all pairs of pixels in a single-photon-sensitive camera, including the case where both entangled photons arrive in the same pixel.

Imaging and Applied Optics•Jan 1, 2018•0 citations

Entangled-photon imaging

Ayman F. Abouraddy

•Jan 1, 2003•0 citations

Accessible “Spooky Action at a Distance”

Tate Thomas, Dulcinea Cabreda

“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.

•Apr 11, 2026•0 citations

PUMP-PROBE SPECTROSCOPY WITH ENTANGLED PHOTONS

Otgonbaatar Myagmar, Duger Ulam-Orgikh, Purevdorj Munkhbaatar

Международная научно-практическая конференция «Вызовы современности и стратегии развития общества в условиях новой реальности»•Jan 1, 2016•0 citations

Microscopy using quantum sources of illumination

Miles J. Padgett

We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)

Photonics for Quantum (PfQ)•Aug 27, 2021•0 citations
“Ghost” imaging is a process utilizing entangled photon pairs, by which an image is produced indirectly, using photons that have never interacted with the object being imaged. We can do this by taking advantage of correlations inherent in Spontaneous Parametric Down Conversion (SPDC), which is used to produce these entangled photon pairs. SPDC is a classically forbidden process in which a photon of a high frequency is converted into a pair of photons. The change in frequency makes this a nonlinear process. Processes like absorption, reflection, refraction, and polarization are linear processes. These can affect the properties of a light field but cannot change the frequency. SPDC allows us to produce a pair of correlated photons. By utilizing a coincidence-counter, we will be able to measure photon pairs from the source beam arriving within a narrow time interval. With this restriction, we can limit our attention to these correlated photons. One of these photons, which does interact with the object to be imaged, is used to turn on a “camera” detecting the other photon. It is the correlations between these photons that allow for ghost imaging, the reconstruction of the image of an object, even though the object never interacts directly with those single photons that are going to our camera.
We use entangled photons as the light source in a normal microscope. Using this quantum illumination improves both the resolution and noise rejection in the image. The resolution of any classical imaging system is limited by the diffraction created by the finite size of the imaging lens. By using a light source that emits pairs of entangled photons and carefully controlling a camera that is capable of detecting single photons it is possible to observe these photons arriving two-by-two. Applying camera analysis software to log only these two-by-two events one can form an image from the mid-point (bisector) of each of these pair events. The image formed from the sum of all these bisectors has an improved resolution that surpasses the classical limit. Another advantage of using a quantum illumination is that it allows the two-by-two events from entangled photon pairs to be distinguished from background (classical) light and sensor noise. When processed in this way the resulting image is free of camera noise and any background light may be eliminated. The use of a quantum illumination protocol such as that used here results in the elimination of background light and therefore allows the development of the optical equivalent of quantum radar – a quantum enhanced LIDAR scheme. Using quantum illumination, combined with commercially available cameras that are sensitive to single photons creates a new approach to super-resolution and low noise microscopy. Imaging through noise with quantum illumination, T Gregory, P-A Moreau, E Toninelli, and M J Padgett, Science Advances 6, eaay2652 (2020) Resolution-enhanced quantum imaging by centroid estimation of biphotons, E Toninelli, P-A Moreau, T Gregory, A Mihalyi, M Edgar, N Radwell, and M J Padgett, Optica 6, 347-353 (2019)