Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Information in correlation detection for plenoptic imaging purposes

Z. Hradil, Martin Paùr, Michal Peterek, Gianlorenzo Massaro, Milena D’Angelo, Francesco Vincenzo Pepe, Jaroslav Řeháček, B. Stoklasa

Published Feb 13, 2025• 0 citations
Publisher

Abstract

In the present work, we quantify the information content of intensity correlation measurements as compared to conventional intensity detection. In particular, we focus on the problem of estimating the separation between two point-like emitters and evaluate Fisher information for the two types of measurements. We consider two different scenarios: intensity correlations are measured, in the first case, in the image plane, and, in the second case, between the image and the Fourier plane of the object. Both detection schemes are shown to benefit from measuring correlations between the detected intensities, a result that indicates the advantages offered by both quantum and quantum-inspired (i.e., correlation-based) imaging protocols over conventional, intensity based, approaches.

DOI
10.1364/oe.541752

Related papers

Metrology of quantum imaging schemes

Emma Brambila, Giacomo Sorelli

We compare the performance of quantum imaging schemes based on spatially correlated photon pairs by formulating them as quantum multiparameter estimation problems, in which the object is characterized by transmission coefficients associated with different spatial modes. Our work focuses on standard quantum imaging techniques such as ghost imaging, two-photon imaging, and imaging with undetected photons. Specifically, we compute the quantum Fisher information matrices and show that they are saturated by Fisher information matrices corresponding to measurements in the object-mode basis, which generalize the common detection schemes employed in each imaging configuration. We find that ghost imaging and two-photon imaging generally provide higher precision for transmission estimation than imaging with undetected photons, but the latter is the only one that naturally does not couple transmission estimation across different spatial modes. These results identify which imaging protocols are best suited for specific tasks and provide practical guidelines for the design and optimization of quantum sensing technologies based on spatial correlations.

quant-pharXiv:2607.22373•Optica Quantum•Jul 27, 2026•0 citations

Quantum Imaging for Space Objects

Francesco Vincenzo Pepe, Alessio Scagliola, Augusto Garuccio +1 more

We aim at developing novel imaging instruments that exploit the intrinsic spatio-temporal correlations of astronomical light sources to bring the quantum advantage in space imaging. These novel instruments differ from standard imaging systems in the way images are retrieved. Conventional images are obtained from direct measurement of the intensity of light coming from the object of interest and recorded by a sensor. Here, instead, we first register optical intensities on two disjoint sensors, and then measure correlations between them. After a brief overview on the state of the art of quantum imaging for space objects, we describe the working principle of Correlation Plenoptic Imaging, which enables to perform 3D imaging and refocusing of out-of-focus objects, and a possible application to satellite imaging.

IEEE International Geoscience and Remote Sensing Symposium (IGARSS)•Sep 26, 2020•1 citation

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Advantages of Multi-photon Detection Revealed by Fisher Information In Resolving Incoherent Sources

Xiao Liang, Yong-Sheng Zhang

With the progress of optical detection technology, the classical diffraction limit raised a hundred years ago has been continuously broken through. In previous experiments within fluorescence sources, one of the techniques used is detecting auto-correlation functions. The image is reconstructed by single-photon and multi-photon detecting intensities. By taking the joint intensity of more than one single-photon detectors into consideration, the point spread function of each photon emitter can be resolved even when the distance of their central position is below the classical diffraction limit. However, the measurement precision is not considered. In actual detecting process the detectors are imperfect, they have quantum detecting efficiency $η$ and even can not count the photon numbers during one absorbing process. Therefore, we analyze the detecting intensity of each detector separately and use the total Fisher information to depict the resolution. Higher Fisher information is obtained when second order correlation function is considered and higher detecting efficiency is beneficial to the Fisher information enhancement, meanwhile the Cramèr-Rao bound for an effective distance resolving is lower than the classical diffraction limits. Furthermore, when the emitted photons are coherent states, the resolution ability can be enhanced with infinite single-photon detectors.

arXiv:1607.05414•Jul 19, 2016•0 citations

Correlation plenoptic imaging with entangled photons

Milena D’Angelo, Augusto Garuccio, Francesco Vincenzo Pepe +4 more

Plenoptic imaging (PI) is an optical technique to perform three-dimensional imaging in a single shot. It is enabled by the simultaneous measurement of both the location and the propagation direction of light in a given scene. Despite being very useful for extending the depth of field, such technique entails a strong trade- off between spatial and angular resolution. This makes the resolution and the maximum achievable depth of focus inversely proportional; hence, resolution cannot be diffraction-limited. We have recently proposed a new procedure, called Correlation Plenoptic Imaging (CPI), to overcome such fundamental limits by collecting plenoptic information through intensity correlation measurement. Using two correlated beams, from either a chaotic or an entangled photon source, we perform imaging in one arm and simultaneously obtain the angular information in the other arm. In this paper, we discuss the case in which the two correlated beams of light are generated by spontaneous parametric down-conversion. We review the principles of CPI with entangled photons and discuss its resolution and depth-of-field limits.

SPIE Quantum Technologies•May 21, 2018•2 citations

Resources in quantum imaging, detection and estimation

Sammy Ragy

The research included in this thesis comes in two main bodies. In the first, the focus is on intensity interferometric schemes, and I attempt to identify the types of correlations dominant in their operation. This starts with the, now rather historical, Hanbury Brown and Twiss setup from the 1950s and progresses to more recent interests such as ghost imaging and a variant of `quantum illumination', which is a quantum-enhanced detection scheme. These schemes are considered in the continuous variable regime, with Gaussian states in particular. Intensity interferometry has been the cause of a number of disputes between quantum opticians over the past 60 years and I weigh in on the arguments using relatively recent techniques from quantum information theory. In the second half, the focus turns away from the optical imaging and detection schemes, and onto quantum estimation -- multiparameter quantum estimation to be precise. This is an intriguing area of study where one has to carefully juggle tradeoffs in choosing both the optimal measurement and optimal state for performing an estimation in two or more parameters. I lay out a framework for circumventing some of the difficulties involved in this and apply it to several physical examples, revealing some interesting and at times counterintuitive features of multiparameter estimation.

•Jul 15, 2015•1 citation
In the present work, we quantify the information content of intensity correlation measurements as compared to conventional intensity detection. In particular, we focus on the problem of estimating the separation between two point-like emitters and evaluate Fisher information for the two types of measurements. We consider two different scenarios: intensity correlations are measured, in the first case, in the image plane, and, in the second case, between the image and the Fourier plane of the object. Both detection schemes are shown to benefit from measuring correlations between the detected intensities, a result that indicates the advantages offered by both quantum and quantum-inspired (i.e., correlation-based) imaging protocols over conventional, intensity based, approaches.
We compare the performance of quantum imaging schemes based on spatially correlated photon pairs by formulating them as quantum multiparameter estimation problems, in which the object is characterized by transmission coefficients associated with different spatial modes. Our work focuses on standard quantum imaging techniques such as ghost imaging, two-photon imaging, and imaging with undetected photons. Specifically, we compute the quantum Fisher information matrices and show that they are saturated by Fisher information matrices corresponding to measurements in the object-mode basis, which generalize the common detection schemes employed in each imaging configuration. We find that ghost imaging and two-photon imaging generally provide higher precision for transmission estimation than imaging with undetected photons, but the latter is the only one that naturally does not couple transmission estimation across different spatial modes. These results identify which imaging protocols are best suited for specific tasks and provide practical guidelines for the design and optimization of quantum sensing technologies based on spatial correlations.
We aim at developing novel imaging instruments that exploit the intrinsic spatio-temporal correlations of astronomical light sources to bring the quantum advantage in space imaging. These novel instruments differ from standard imaging systems in the way images are retrieved. Conventional images are obtained from direct measurement of the intensity of light coming from the object of interest and recorded by a sensor. Here, instead, we first register optical intensities on two disjoint sensors, and then measure correlations between them. After a brief overview on the state of the art of quantum imaging for space objects, we describe the working principle of Correlation Plenoptic Imaging, which enables to perform 3D imaging and refocusing of out-of-focus objects, and a possible application to satellite imaging.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
With the progress of optical detection technology, the classical diffraction limit raised a hundred years ago has been continuously broken through. In previous experiments within fluorescence sources, one of the techniques used is detecting auto-correlation functions. The image is reconstructed by single-photon and multi-photon detecting intensities. By taking the joint intensity of more than one single-photon detectors into consideration, the point spread function of each photon emitter can be resolved even when the distance of their central position is below the classical diffraction limit. However, the measurement precision is not considered. In actual detecting process the detectors are imperfect, they have quantum detecting efficiency ηηη and even can not count the photon numbers during one absorbing process. Therefore, we analyze the detecting intensity of each detector separately and use the total Fisher information to depict the resolution. Higher Fisher information is obtained when second order correlation function is considered and higher detecting efficiency is beneficial to the Fisher information enhancement, meanwhile the Cramèr-Rao bound for an effective distance resolving is lower than the classical diffraction limits. Furthermore, when the emitted photons are coherent states, the resolution ability can be enhanced with infinite single-photon detectors.
Plenoptic imaging (PI) is an optical technique to perform three-dimensional imaging in a single shot. It is enabled by the simultaneous measurement of both the location and the propagation direction of light in a given scene. Despite being very useful for extending the depth of field, such technique entails a strong trade- off between spatial and angular resolution. This makes the resolution and the maximum achievable depth of focus inversely proportional; hence, resolution cannot be diffraction-limited. We have recently proposed a new procedure, called Correlation Plenoptic Imaging (CPI), to overcome such fundamental limits by collecting plenoptic information through intensity correlation measurement. Using two correlated beams, from either a chaotic or an entangled photon source, we perform imaging in one arm and simultaneously obtain the angular information in the other arm. In this paper, we discuss the case in which the two correlated beams of light are generated by spontaneous parametric down-conversion. We review the principles of CPI with entangled photons and discuss its resolution and depth-of-field limits.
The research included in this thesis comes in two main bodies. In the first, the focus is on intensity interferometric schemes, and I attempt to identify the types of correlations dominant in their operation. This starts with the, now rather historical, Hanbury Brown and Twiss setup from the 1950s and progresses to more recent interests such as ghost imaging and a variant of `quantum illumination', which is a quantum-enhanced detection scheme. These schemes are considered in the continuous variable regime, with Gaussian states in particular. Intensity interferometry has been the cause of a number of disputes between quantum opticians over the past 60 years and I weigh in on the arguments using relatively recent techniques from quantum information theory. In the second half, the focus turns away from the optical imaging and detection schemes, and onto quantum estimation -- multiparameter quantum estimation to be precise. This is an intriguing area of study where one has to carefully juggle tradeoffs in choosing both the optimal measurement and optimal state for performing an estimation in two or more parameters. I lay out a framework for circumventing some of the difficulties involved in this and apply it to several physical examples, revealing some interesting and at times counterintuitive features of multiparameter estimation.