Entangled Quantum Imaging Method Based on Two-Step Adaptive Sampling Optimization

Zhongyin Hu, Mu Zhou, Yong Ma, Jiacheng Wang, Zuoliang Yin, Brian D. Gerardot

Published Jan 8, 2025• 1 citation
Publisher

Abstract

In recent years, quantum information technology, as a subversive and strategic technology that has attracted much attention, acquires, transmits, and processes information by means of unique physical phenomena such as quantum entanglement, nonlocality, and non-cloning. Quantum imaging technology achieves non-local imaging of targets by extracting entangled light quantum information with temporal and spatial correlation characteristics. By using the anti-interference and anti-turbulence characteristics of quantum entangled states, quantum imaging technology can break through the physical limits of traditional imaging fields, thereby improving imaging resolution and sensitivity. The latest technological development in quantum imaging has prompted researchers to study high-resolution and fast quantum imaging based on the spatial correlation characteristics of entangled photon pairs. In this circumstance, we propose a novel quantum imaging method based on two-step adaptive sampling optimization and carry out experimental verification. In concrete terms, in order to solve the problem that the efficiency of entangled light quantum imaging is limited by Digital Micromirror Device (DMD) sampling, we select the two-step adaptive sampling optimization algorithm to reduce the influence of DMD scanning on imaging efficiency. At the same time, for the sake of solving the problem that the quality of entangled photon quantum imaging is limited by the accuracy of coincidence counting, we add delay difference calculation in the imaging process and correct the signal photon arrival time pulse sequence to ensure the accuracy of coincidence counting. Finally, we conduct a large number of experiments to evaluate the performance of the two-step adaptive sampling optimization algorithm and verify the superiority of the proposed entangled quantum imaging method practically.

DOI
10.1109/jstqe.2025.3527018

Related papers

Entangled Light 3-D Quantum Imaging Method Based on Adaptive Depth Compression

Zhongyin Hu, Mu Zhou, Jingyang Cao +3 more

Aiming at the problems of sampling redundancy, insufficient accuracy, and noise sensitivity of traditional quantum depth imaging methods in low-light and long-distance scenes, an entangled light 3-D quantum imaging method based on adaptive depth compression is proposed. This method combines the spatiotemporal correlation and anti-interference characteristics of quantum entangled photon pairs, integrates compressed sensing theory to break through the bottleneck of Nyquist sampling, and achieves efficient imaging by dynamically adjusting the sampling strategy. Based on the time-of-flight difference between signal photons and noise photons, an adaptive algorithm is designed to optimize the sampling integration time and compression measurement matrix of each pixel in real time: the sampling amount is reduced in the high-reflectivity region, and the sampling time is extended in the low-reflectivity region. At the same time, quantum entanglement is used to improve the detection sensitivity of weak light signals. Simulation and experimental results show that the proposed method can significantly reduce the number of sampling operations and imaging time, while maintaining excellent depth estimation accuracy and robustness, and, thus, provide a new technical path for low-light, long-distance, and real-time 3-D imaging.

IEEE Internet of Things Journal•Jul 6, 2026•0 citations

Ranging-assisted Quantum Imaging Method Based on Coincidence Counting

Changyin Ji, Mu Zhou, Yong Wang +2 more

In order to reduce the time overhead of quantum imaging, a new ranging-assisted quantum imaging method based on coincidence counting is proposed in this paper. Firstly, the Digital Micromirror Device (DMD) is used to select the ranging area in the imaging area, and photon arrival time sequences on signal and reference light paths are recorded by delay coincidence. Secondly, the second-order correlation curve is drawn according to the coincidence count values to obtain the delay difference of these two optical paths. This delay difference corrects the photon arrival time sequences corresponding to the imaging area. Finally, the coincidence counting is performed based on the corrected time sequences, and the quantum imaging result is obtained according to the coincidence count values. Experimental results show that the proposed method can greatly reduce the time overhead of quantum imaging.

IEEE Asia-Pacific Conference on Antennas and Propagation•Nov 4, 2022•2 citations

An Entangled Quantum Imaging Method Based on Photon Capture Probability in Weak-Turbulence Environment

Jingyang Cao, Wei Nie, Mu Zhou

Entangled photon quantum imaging technology has broad application prospects in ocean imaging due to its high resolution, anti-turbulence and anti-interference characteristics. Turbulence and optical attenuation caused by seawater will seriously limit the traditional imaging system, and quantum imaging based on entangled light source can overcome the limitations of low imaging resolution, large impact on marine environment and low confidentiality in traditional underwater target imaging. Based on the propagation characteristics of weak turbulent environment, we propose a new photon capture probability algorithm for marine environment based on entangled photon pairs. Finally, the relevant experimental environment is constructed according to the designed imaging optical path. We conduct extensive experiments to evaluate the effectiveness of our proposed quantum imaging method.

ACM Annual International Conference on Mobile Computing and Networking (MobiCom)•Sep 30, 2023•1 citation

A High-Resolution and Low-Cost Entangled Photon Quantum Imaging Framework for Marine Turbulence Environment

Jingyang Cao, Wei Nie, Mu Zhou

Entangled photon quantum imaging technology has become very promising for marine imaging due to its high resolution, anti-turbulence, and anti-interference properties. The turbulence and optical attenuation caused by oceanic water would impose severe limitations on conventional imaging equipment. Quantum imaging based on entangled light sources could make it possible to overcome the constraints of low imaging resolution, large maritime environmental impact and low confidentiality in traditional underwater target imaging. Hence, the recent technological developments in terms of quantum imaging in free space motivate our investigation into high-resolution quantum imaging based on spatially correlated properties of entangled photon pairs in a marine environment. Moreover we propose and design an innovative underwater quantum imaging optical path for experimental verification. We conduct extensive experiments to assess the effectiveness of our proposed quantum imaging approach in marine environments. In order to solve the problem of the slow quantum imaging process, we propose an innovative compressive sensing reconstruction algorithm. Experiments show that the compressive sensing method could be utilized to reduce the imaging time. Finally, we propose an underwater quantum target identification method based on deep learning, further providing the possibility for underwater quantum target identification of entangled light sources.

IEEE Network•Sep 1, 2022•7 citations

Quantum 3-D Imaging and Reflectivity Estimation Based on Entangled Photons in Low-Light Environments

Mu Zhou, Jiangli Peng, Jingyang Cao +2 more

Three-dimensional (3D) imaging in low-light environments has broad application prospects. High-quality 3D imaging requires obtaining both the depth and reflectivity information of the target. With the rapid development of Quantum Information Technology (QIT), Quantum Imaging (QI) provides a new approach to achieve high-quality 3D imaging. However, traditional QI methods are limited to Two-dimensional (2D) imaging and cannot accurately extract the depth information from the target. These methods also suffer from insufficient precision in reflectivity calculations. Therefore, we introduce a novel quantum 3D imaging and reflectivity estimation method based on entangled photons. Specifically, we first utilize the spatiotemporal correlation characteristics of entangled photon pairs combined with coincidence measurement technology to accurately determine target depth. Second, we analyze the distribution of entangled photon numbers during free-space transmission to construct a photon-based detection probability model. Third, we use this model to derive the probability density function of coincidence counts. Finally, we estimate the surface reflectivity information through statistical analysis of coincidence counting. Experimental results demonstrate that the proposed method can accurately reconstruct both depth and reflectivity profiles of the target in low-light environments. These findings validate the effectiveness of our method and highlight the potential of quantum 3D imaging for target detection in low-light environments.

IEEE Internet of Things Journal•Sep 1, 2025•3 citations

Robust Optical Quantum Imaging Framework With Entangled Photons in Oceanic Turbulent Environments

Jingyang Cao, Mu Zhou, Ruichen Zhang +3 more

As an important part of underwater optical technology, underwater imaging plays a crucial role in accurately capturing underwater targets and environmental features. Facing the challenges of complex ocean environments and severe photon attenuation, quantum imaging breaks through the limitations of traditional optical imaging technology by utilizing the characteristics of two-photon entanglement and time-space correlation, thus offering a new perspective on ocean turbulence. To this end, we propose a new underwater entangled-photon quantum imaging system. Specifically, we first construct an entangled photon quantum imaging physical model through ocean long-exposure turbulence and then exploit an entangled light coincidence imaging reconstruction method to image the target object. Furthermore, in response to the problem that ocean environment has a great impact on photons, we develop a photon capture probability method based on entangled photon pairs to reduce the impact of the ocean turbulence noise on imaging and improve the underwater target imaging resolution. We experimentally demonstrate the effectiveness of our method by showing that even in harsh ocean environments, quantum imaging performs superior resolution capabilities over traditional light source imaging techniques.

IEEE Transactions on Communications•Feb 4, 2025•5 citations
In recent years, quantum information technology, as a subversive and strategic technology that has attracted much attention, acquires, transmits, and processes information by means of unique physical phenomena such as quantum entanglement, nonlocality, and non-cloning. Quantum imaging technology achieves non-local imaging of targets by extracting entangled light quantum information with temporal and spatial correlation characteristics. By using the anti-interference and anti-turbulence characteristics of quantum entangled states, quantum imaging technology can break through the physical limits of traditional imaging fields, thereby improving imaging resolution and sensitivity. The latest technological development in quantum imaging has prompted researchers to study high-resolution and fast quantum imaging based on the spatial correlation characteristics of entangled photon pairs. In this circumstance, we propose a novel quantum imaging method based on two-step adaptive sampling optimization and carry out experimental verification. In concrete terms, in order to solve the problem that the efficiency of entangled light quantum imaging is limited by Digital Micromirror Device (DMD) sampling, we select the two-step adaptive sampling optimization algorithm to reduce the influence of DMD scanning on imaging efficiency. At the same time, for the sake of solving the problem that the quality of entangled photon quantum imaging is limited by the accuracy of coincidence counting, we add delay difference calculation in the imaging process and correct the signal photon arrival time pulse sequence to ensure the accuracy of coincidence counting. Finally, we conduct a large number of experiments to evaluate the performance of the two-step adaptive sampling optimization algorithm and verify the superiority of the proposed entangled quantum imaging method practically.
Aiming at the problems of sampling redundancy, insufficient accuracy, and noise sensitivity of traditional quantum depth imaging methods in low-light and long-distance scenes, an entangled light 3-D quantum imaging method based on adaptive depth compression is proposed. This method combines the spatiotemporal correlation and anti-interference characteristics of quantum entangled photon pairs, integrates compressed sensing theory to break through the bottleneck of Nyquist sampling, and achieves efficient imaging by dynamically adjusting the sampling strategy. Based on the time-of-flight difference between signal photons and noise photons, an adaptive algorithm is designed to optimize the sampling integration time and compression measurement matrix of each pixel in real time: the sampling amount is reduced in the high-reflectivity region, and the sampling time is extended in the low-reflectivity region. At the same time, quantum entanglement is used to improve the detection sensitivity of weak light signals. Simulation and experimental results show that the proposed method can significantly reduce the number of sampling operations and imaging time, while maintaining excellent depth estimation accuracy and robustness, and, thus, provide a new technical path for low-light, long-distance, and real-time 3-D imaging.
In order to reduce the time overhead of quantum imaging, a new ranging-assisted quantum imaging method based on coincidence counting is proposed in this paper. Firstly, the Digital Micromirror Device (DMD) is used to select the ranging area in the imaging area, and photon arrival time sequences on signal and reference light paths are recorded by delay coincidence. Secondly, the second-order correlation curve is drawn according to the coincidence count values to obtain the delay difference of these two optical paths. This delay difference corrects the photon arrival time sequences corresponding to the imaging area. Finally, the coincidence counting is performed based on the corrected time sequences, and the quantum imaging result is obtained according to the coincidence count values. Experimental results show that the proposed method can greatly reduce the time overhead of quantum imaging.
Entangled photon quantum imaging technology has broad application prospects in ocean imaging due to its high resolution, anti-turbulence and anti-interference characteristics. Turbulence and optical attenuation caused by seawater will seriously limit the traditional imaging system, and quantum imaging based on entangled light source can overcome the limitations of low imaging resolution, large impact on marine environment and low confidentiality in traditional underwater target imaging. Based on the propagation characteristics of weak turbulent environment, we propose a new photon capture probability algorithm for marine environment based on entangled photon pairs. Finally, the relevant experimental environment is constructed according to the designed imaging optical path. We conduct extensive experiments to evaluate the effectiveness of our proposed quantum imaging method.
Entangled photon quantum imaging technology has become very promising for marine imaging due to its high resolution, anti-turbulence, and anti-interference properties. The turbulence and optical attenuation caused by oceanic water would impose severe limitations on conventional imaging equipment. Quantum imaging based on entangled light sources could make it possible to overcome the constraints of low imaging resolution, large maritime environmental impact and low confidentiality in traditional underwater target imaging. Hence, the recent technological developments in terms of quantum imaging in free space motivate our investigation into high-resolution quantum imaging based on spatially correlated properties of entangled photon pairs in a marine environment. Moreover we propose and design an innovative underwater quantum imaging optical path for experimental verification. We conduct extensive experiments to assess the effectiveness of our proposed quantum imaging approach in marine environments. In order to solve the problem of the slow quantum imaging process, we propose an innovative compressive sensing reconstruction algorithm. Experiments show that the compressive sensing method could be utilized to reduce the imaging time. Finally, we propose an underwater quantum target identification method based on deep learning, further providing the possibility for underwater quantum target identification of entangled light sources.
Three-dimensional (3D) imaging in low-light environments has broad application prospects. High-quality 3D imaging requires obtaining both the depth and reflectivity information of the target. With the rapid development of Quantum Information Technology (QIT), Quantum Imaging (QI) provides a new approach to achieve high-quality 3D imaging. However, traditional QI methods are limited to Two-dimensional (2D) imaging and cannot accurately extract the depth information from the target. These methods also suffer from insufficient precision in reflectivity calculations. Therefore, we introduce a novel quantum 3D imaging and reflectivity estimation method based on entangled photons. Specifically, we first utilize the spatiotemporal correlation characteristics of entangled photon pairs combined with coincidence measurement technology to accurately determine target depth. Second, we analyze the distribution of entangled photon numbers during free-space transmission to construct a photon-based detection probability model. Third, we use this model to derive the probability density function of coincidence counts. Finally, we estimate the surface reflectivity information through statistical analysis of coincidence counting. Experimental results demonstrate that the proposed method can accurately reconstruct both depth and reflectivity profiles of the target in low-light environments. These findings validate the effectiveness of our method and highlight the potential of quantum 3D imaging for target detection in low-light environments.
As an important part of underwater optical technology, underwater imaging plays a crucial role in accurately capturing underwater targets and environmental features. Facing the challenges of complex ocean environments and severe photon attenuation, quantum imaging breaks through the limitations of traditional optical imaging technology by utilizing the characteristics of two-photon entanglement and time-space correlation, thus offering a new perspective on ocean turbulence. To this end, we propose a new underwater entangled-photon quantum imaging system. Specifically, we first construct an entangled photon quantum imaging physical model through ocean long-exposure turbulence and then exploit an entangled light coincidence imaging reconstruction method to image the target object. Furthermore, in response to the problem that ocean environment has a great impact on photons, we develop a photon capture probability method based on entangled photon pairs to reduce the impact of the ocean turbulence noise on imaging and improve the underwater target imaging resolution. We experimentally demonstrate the effectiveness of our method by showing that even in harsh ocean environments, quantum imaging performs superior resolution capabilities over traditional light source imaging techniques.