Physical Review Applied

Suppressing background spectra of lattice lasers in strontium optical clocks

Zhi-Peng Jia, Xing-Yang Cui, Yan-Jun Xie, Xiang Zhang, Guo-Zhen Niu, Xiao-Yong Liu, Qingqing Zhu, Jie Li, Han-Ning Dai

Published Jan 6, 2025• 5 citations
Publisher

Abstract

Recent assessments have enhanced the evaluation of the lattice ac Stark shift in optical clocks to a fractional frequency level below ${10}^{\ensuremath{-}18}$. With this level of accuracy, meticulous attention is required to address shifts from the background spectrum of the lattice laser. Therefore, it is essential for the lattice laser to exhibit a minimal background spectrum. In this investigation, we employ a system based on sum-frequency generation (SFG) of the fiber-amplified lasers as the source for the strontium optical-clock lattice laser. The spectrum purity of this laser system has been confirmed through a heterodyne measurement involving a titanium:sapphire ($\mathrm{Ti}$:$\mathrm{Sa}$) laser. Consequently, we have characterized the background light shift resulting from its background spectrum, which is more than one order of magnitude lower than that of a tapered amplifier (TA). Through the implementation of carefully selected spectral filtering, the background light shift can be suppressed to a level of mid-${10}^{\ensuremath{-}20}$. Additionally, the suitability of the SFG laser is also experimentally verified in a strontium clock.

DOI
10.1103/physrevapplied.23.014014

Related papers

Characterization and Suppression of Background Light Shifts in an Optical Lattice Clock

Robert Fasano, Yun-Jhih Chen, William F. McGrew +3 more

Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancelation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancelation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes that can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in a Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the ${10}^{\ensuremath{-}18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.

arXiv:2103.12052•Physical Review Applied•Apr 8, 2021•25 citations

Lattice light shift in strontium optical clock

G S Belotelov, Vitalii D Ovsiannikov, Denis V. Sutyrin +5 more

Abstract Results of theoretical evaluations of uncertainties arising from the atom-lattice interaction effects on the clock frequency are presented for Sr atoms. Possibilities for simultaneous tuning of optical lattice frequency and intensity parameters are discussed aiming at minimizing uncertainties induced by interaction of Sr atoms with the field of magic-wavelength optical lattice. The fractional contributions to the clock-frequency shift from the spontaneous emission of the lattice-beam amplifier after having passed the optical fiber are determined at the level below 10 −18 .

Laser Physics•Mar 25, 2020•5 citations

Estimation of reducing the impact of the optical lattice spectrum on the optical clock frequency shift

Mikhail Gurov, Elena G. Gurova

In this paper the method for reducing the shift of the "clock" resonance by the example of 87 Sr has been described. This shift arises due to the presence in the optical spectrum of the lattice laser of the incoherent component. This component is a traveling wave. It is shown that the effective decrease of the impact on the shift of the "clock" resonance by introducing the interference filter is achieved. This filter was inserted directly into the optical scheme after the laser source. Examples of the optical lattice spectra with and without filter are considered. The estimates of the efficiency ratio of the use of the interference filters to improve the final uncertainty of the optical reference are made. It is shown that the filter reduces the relative uncertainty from the impact of the incoherent component of the optical radiation of the optical lattice by two orders of magnitude. It should help to reduce the lower bound for the total uncertainty limit of the optical frequency clocks down to 10 −18 .

Journal of Physics Conference Series•Oct 1, 2021•0 citations

Magic Wavelength Measurement of the 87 Sr Optical Lattice Clock at NIM

Qiang Wang, Yige Lin, Fei Meng +5 more

We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.

Chinese Physics Letters•Oct 1, 2016•9 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•39 citations

Spectroscopy schemes for improved optical clock stability

Filip Butuc-Mayer

Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.

•Jan 1, 2026•0 citations
Recent assessments have enhanced the evaluation of the lattice ac Stark shift in optical clocks to a fractional frequency level below 10\ensuremath−18{10}^{\ensuremath{-}18}10\ensuremath−18. With this level of accuracy, meticulous attention is required to address shifts from the background spectrum of the lattice laser. Therefore, it is essential for the lattice laser to exhibit a minimal background spectrum. In this investigation, we employ a system based on sum-frequency generation (SFG) of the fiber-amplified lasers as the source for the strontium optical-clock lattice laser. The spectrum purity of this laser system has been confirmed through a heterodyne measurement involving a titanium:sapphire (Ti\mathrm{Ti}Ti:Sa\mathrm{Sa}Sa) laser. Consequently, we have characterized the background light shift resulting from its background spectrum, which is more than one order of magnitude lower than that of a tapered amplifier (TA). Through the implementation of carefully selected spectral filtering, the background light shift can be suppressed to a level of mid-10\ensuremath−20{10}^{\ensuremath{-}20}10\ensuremath−20. Additionally, the suitability of the SFG laser is also experimentally verified in a strontium clock.
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancelation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancelation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes that can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in a Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the ${10}^{\ensuremath{-}18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.
Abstract Results of theoretical evaluations of uncertainties arising from the atom-lattice interaction effects on the clock frequency are presented for Sr atoms. Possibilities for simultaneous tuning of optical lattice frequency and intensity parameters are discussed aiming at minimizing uncertainties induced by interaction of Sr atoms with the field of magic-wavelength optical lattice. The fractional contributions to the clock-frequency shift from the spontaneous emission of the lattice-beam amplifier after having passed the optical fiber are determined at the level below 10 −18 .
In this paper the method for reducing the shift of the "clock" resonance by the example of 87 Sr has been described. This shift arises due to the presence in the optical spectrum of the lattice laser of the incoherent component. This component is a traveling wave. It is shown that the effective decrease of the impact on the shift of the "clock" resonance by introducing the interference filter is achieved. This filter was inserted directly into the optical scheme after the laser source. Examples of the optical lattice spectra with and without filter are considered. The estimates of the efficiency ratio of the use of the interference filters to improve the final uncertainty of the optical reference are made. It is shown that the filter reduces the relative uncertainty from the impact of the incoherent component of the optical radiation of the optical lattice by two orders of magnitude. It should help to reduce the lower bound for the total uncertainty limit of the optical frequency clocks down to 10 −18 .
We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.