Optics Express

Nonlinear and nonlinear-linear hybrid interferometers using coherent and squeezed vacuum states

Jiandong Zhang, Fan Jia, Lili Hou, Shuai Wang

Published Dec 13, 2024• 2 citations
Publisher

Abstract

Classical and quantum states working in concert play an essential role in high-precision interferometry. In this regard, coherent combined with squeezed vacuum states are the most promising candidate. Here we complement this subject by comparing nonlinear and nonlinear-linear hybrid interferometers with homodyne detection as a readout strategy. For a high-photon coherent state, either of the two interferometers can provide the phase sensitivity approaching the quantum Cramer-Rao bound. Additionally, we discuss the impacts of photon loss during the transmission and readout stages. We find that a nonlinear interferometer is advantageous over a nonlinear-linear hybrid interferometer. With increasing photon number of the coherent state, the maximal tolerable lossy rate ensuring phase sensitivity beyond the shot-noise limit is close to 50%. Our work may deepen the understanding of quantum-enhanced interferometry using nonlinear dynamics.

DOI
10.1364/oe.544878

Related papers

Nonlinear phase estimation via nonlinear-linear hybrid interferometers

Jiandong Zhang, Chuang Li, Shuai Wang

Estimating nonlinear phase shifts is useful to analyze many dynamical processes. In this work, with respect to the second-order nonlinear phase shifts, we propose an estimation scheme with a coherent state as the input and balanced homodyne detection as the readout strategy. The measurement setup is a nonlinear-linear hybrid interferometer composed of an optical parametric amplifier and a beam splitter. We analyze the precision and determine the optimal parameters of our scheme. The precision is compared with the quantum Cramér–Rao bound as well as the precision of a conventional nonlinear interferometer. In view of the fact that photon loss is ubiquitous, the effects of transmission loss and detection loss on the precision are addressed. At low gain, our scheme is superior to the scheme using a conventional nonlinear interferometer, and the precision can saturate the quantum Cramér–Rao bound.

Journal of the Optical Society of America B•Mar 21, 2022•5 citations

Enhancing Phase Estimation in a Hybrid Interferometer via Kerr Nonlinearity and Photon Subtraction

Lifen Guo, Qingqian Kang, Zekun Zhao +5 more

We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling ($1/N$), and approach the super-Heisenberg scaling ($1/N^{2}$)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ $1/N^{2}$ is the ultimate precision limit permitted by the $k=2$ Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.

quant-pharXiv:2605.20893•May 21, 2026•0 citations

Improving phase sensitivity of a hybrid interferometer with the two-mode squeezed coherent state

Tao Shao, Pengxiang Ruan, Minyang Zhang +4 more

Abstract We investigate the enhancement of phase sensitivity of a nonlinear-linear hybrid interferometer with the input of the two-mode squeezed coherent state (TMSCS). With the TMSCS produced by four-wave mixing, the quantum Cramér-Rao bounds (QCRB) can beat the Heisenberg limit (HL). Under the phase matched conditions, the optimal phase sensitivity with the balanced homodyne detection measurement can beat the HL and approach QCRB. The effects of internal and external losses on the measurement accuracy are also discussed. The results demonstrate that the scheme is robustness against to internal losses and this protocol can resist external detection loss which is up to 39%. Our results improve the performance of hybrid interferometers and this scheme can find important practical applications in quantum metrology.

Physica Scripta•Sep 18, 2024•5 citations

Quantum optical metrology in the lossy SU(2) and SU(1,1) interferometers

Yang Gao

We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.

arXiv:1606.08966•Physical Review A•Aug 18, 2016•25 citations

Enhanced phase estimation with a displaced two-mode squeezed coherent state

Pengxiang Ruan, Jun Liu, Dong-Xu Chen

Compared to classical state inputs, using quantum states in interferometers, especially squeezed states, can greatly improve the accuracy of the phase estimation. Here, we propose a scheme based on a Mach-Zehnder interferometer with a displaced two-mode squeezed coherent state input. The scheme employs both intensity difference detection and balanced homodyne detection to achieve high phase sensitivity. The displaced squeezed state exhibits higher accuracy and better robustness by theoretical calculations. For the state, the phase sensitivity of the quantum Cramér-Rao bound and intensity difference detection both exceed the shot noise limit. Additionally, we demonstrate that the proposed state is superior to the two-mode squeezed coherent state by analyzing different displacement operations. Under the presence of both the interferometric transmission loss and the detection loss, higher displacement strength yields higher robustness. To the best of our knowledge, our work provides new ideas for the field of precision measurement.

Optics Express•Nov 4, 2025•0 citations

Enhanced phase sensitivity of the Mach-Zehnder-type phase-shifting interferometry with single-intensity and difference-intensity detection

Huanrong He, Yu Zhang

Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.

Optics Express•Jul 17, 2026•0 citations
Classical and quantum states working in concert play an essential role in high-precision interferometry. In this regard, coherent combined with squeezed vacuum states are the most promising candidate. Here we complement this subject by comparing nonlinear and nonlinear-linear hybrid interferometers with homodyne detection as a readout strategy. For a high-photon coherent state, either of the two interferometers can provide the phase sensitivity approaching the quantum Cramer-Rao bound. Additionally, we discuss the impacts of photon loss during the transmission and readout stages. We find that a nonlinear interferometer is advantageous over a nonlinear-linear hybrid interferometer. With increasing photon number of the coherent state, the maximal tolerable lossy rate ensuring phase sensitivity beyond the shot-noise limit is close to 50%. Our work may deepen the understanding of quantum-enhanced interferometry using nonlinear dynamics.
Estimating nonlinear phase shifts is useful to analyze many dynamical processes. In this work, with respect to the second-order nonlinear phase shifts, we propose an estimation scheme with a coherent state as the input and balanced homodyne detection as the readout strategy. The measurement setup is a nonlinear-linear hybrid interferometer composed of an optical parametric amplifier and a beam splitter. We analyze the precision and determine the optimal parameters of our scheme. The precision is compared with the quantum Cramér–Rao bound as well as the precision of a conventional nonlinear interferometer. In view of the fact that photon loss is ubiquitous, the effects of transmission loss and detection loss on the precision are addressed. At low gain, our scheme is superior to the scheme using a conventional nonlinear interferometer, and the precision can saturate the quantum Cramér–Rao bound.
We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling (1/N1/N1/N), and approach the super-Heisenberg scaling (1/N21/N^{2}1/N2)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ 1/N21/N^{2}1/N2 is the ultimate precision limit permitted by the k=2k=2k=2 Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.
Abstract We investigate the enhancement of phase sensitivity of a nonlinear-linear hybrid interferometer with the input of the two-mode squeezed coherent state (TMSCS). With the TMSCS produced by four-wave mixing, the quantum Cramér-Rao bounds (QCRB) can beat the Heisenberg limit (HL). Under the phase matched conditions, the optimal phase sensitivity with the balanced homodyne detection measurement can beat the HL and approach QCRB. The effects of internal and external losses on the measurement accuracy are also discussed. The results demonstrate that the scheme is robustness against to internal losses and this protocol can resist external detection loss which is up to 39%. Our results improve the performance of hybrid interferometers and this scheme can find important practical applications in quantum metrology.
We study the phase sensitivity in the conventional SU(2) and nonconventional SU(1,1) interferometers with a coherent and squeezed vacuum input state via quantum Cramer-Rao bound. We explicitly construct the detection scheme that gives the optimal phase sensitivity. For practical purposes, we show that in the presence of photon loss, both interferometers with proper homodyne detections are nearly optimal. We also find that unlike the coherent state and the squeezed vacuum state, the effects of imperfect detector on the phase sensitivity cannot be asymptotically removed for a generic coherent-squeezed state.
Compared to classical state inputs, using quantum states in interferometers, especially squeezed states, can greatly improve the accuracy of the phase estimation. Here, we propose a scheme based on a Mach-Zehnder interferometer with a displaced two-mode squeezed coherent state input. The scheme employs both intensity difference detection and balanced homodyne detection to achieve high phase sensitivity. The displaced squeezed state exhibits higher accuracy and better robustness by theoretical calculations. For the state, the phase sensitivity of the quantum Cramér-Rao bound and intensity difference detection both exceed the shot noise limit. Additionally, we demonstrate that the proposed state is superior to the two-mode squeezed coherent state by analyzing different displacement operations. Under the presence of both the interferometric transmission loss and the detection loss, higher displacement strength yields higher robustness. To the best of our knowledge, our work provides new ideas for the field of precision measurement.
Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.