IEEE Transactions on Applied Superconductivity

Quasi-Lumped Coplanar Waveguide Diplexers for a Multichroic Polarimeter

Sirui Ren, Tian Xia, Shiling Yu, Yu Wang, Mingzhu Zhang, Yuxin Qiu, Xiaohui Yan, Ruirui Fan, Xucheng Dai, Zhanzhang Mai, Zhongyu Shi, Yue Hong, Liming Zou, Haitao Wang, Hongli Zhu, Jiawei Liu, Haoyu Wang, Weijie Guo, Yiwen Wang, Yanru Song, Xiaohang Zhang, Ran Duan

Published Dec 12, 2024• 0 citations
Publisher

Abstract

This article presents a multichroic Kinetic Inductance Bolometer (KIB) polarimeter that utilizes coplanar waveguide (CPW) diplexers. The CPW diplexers function as filters, providing two passbands centered at 220 GHz and 280 GHz. The high-quality-factor resonant units deliver excellent transmission and isolation characteristics. Additionally, the quasi-lumped-element resonator design enables a significant reduction in size compared to conventional microstrip diplexers. The entire polarimeter—comprising orthomode transducer (OMT) probes, diplexers, KIBs, and CPW feed lines—is integrated on a single plane, allowing for one-layer superconducting thin-film fabrication with a simplified process. The compact size, superior frequency response, and streamlined fabrication process make the proposed pixel scheme suitable for integrated array development.

DOI
10.1109/tasc.2024.3514596

Related papers

Superconducting sub-millimeter diplexer suitable for pixel-size two-band bolometric detection

Philippe Camus, D. Rauly, O. Guillaudin +3 more

The design of a diplexer, coupled to a planar bowtie antenna for two-band Cosmic Microwave Background detection is proposed, using both HFSS™ and ADS™ softwares. The two photometric bands are centered on 150 GHz and 220 GHz respectively. The diplexer is composed of two three-elements distributed filtering circuits, taking into account the complex impedance of the antenna and the impedance of the two resistive loading bolometers. The distributed elements are transmission lines Coplanar Strip Lines (CPS) and Broadside Coupled Lines (BCL). Their balanced geometry matches to the differential signal delivered by the bow-tie antenna, avoiding the addition of a balun circuit. The envisaged technology for strips and antenna is superconducting niobium at a few 100mK on Si substrate. The overall size of the antenna/diplexer structure is around 2 mm2, allowing to consider it as a pixel suitable for integration in a bolometer array.

SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC)•Jan 1, 2007•0 citations

A superconducting diplexer for cosmic microwave background experiments

Mohammad Madi, Michael Mattes, Juan Ramon Mosig +2 more

Cosmic microwave background (CMB) studies require observations in several frequency bands simultaneously. For example, the detection of clusters of remote galaxies can be performed by comparing CMB photon fluxes at different frequencies, using the spectral deformation of the Planck law, due to the Sunyaev–Zeldovich effect. We propose a single pixel design to receive and detect simultaneously two frequency bands of the (CMB), centered at 150 and 220 GHz. It is composed of a bow-tie antenna, sensitive to the polarization of the incident radiation, feeding a diplexer structure to separate the signal towards two kinetic inductance resonators associated respectively with the 130–170 and 200–270 GHz frequency bands. The diplexer makes use of 150 nm thick niobium-based superconducting transmission lines of the coplanar strip-lines (CPS) type, for filtering and separation purposes, deposited on a 30 μm thick quartz substrate. A new coplanar matching structure, taking into account the kinetic inductance of the superconducting films, is proposed and achieves a nearly perfect match over more than 25% of each frequency band, along with a signal separation ratio above 30 dB at both center frequencies. The size of a single pixel is 0.9 mm × 1.2 mm.

Superconductor Science and Technology•Dec 5, 2013•0 citations

Design of Two-band 150-220 GHz Superconducting Bolometric Detection Structure

D. Rauly, A. Monfardini, Angel Colín +1 more

We propose a pixel design, aimed to be included in an array, receiving and de- tecting simultaneously two bands of the Cosmic Microwave Background (CMB). It is composed of a bowtie antenna, feeding a diplexer structure to separate the signal towards two bolomet- ric detectors at 150 and 220GHz. The diplexer makes use of difierential transmission lines of Coplanar Striplines (CPS) and Broadside Coupled Lines (BCL) types, for flltering and separation purposes. The antenna and diplexer are planned to be fabricated in a superconductive niobium thin fllm deposited on a Silicon substrate, while NbSi bolometers will lie on a SiN membrane. The device has been simulated by means of ADS (Agilent), CST Microwave Studio and HFSS (Ansoft) softwares. Final dimensions that take into account the kinetic inductance of the super- conducting lines are proposed. Promising computation results are found, with signal separation up to 20dB.

PIERS Online•Jan 1, 2008•3 citations

Dual polarization kinetic inductance detectors for large imaging cameras at millimeter wave bands

E. Artal, B. Aja, Luisa de la Fuente +8 more

This work deals with the development of superconducting Kinetic Inductance Detectors (KIDs) for highly sensitive radio astronomy receivers within W-band (75 to 110 GHz). A bilayer based on superconducting titanium/aluminum (Ti/Al) thin films has been used for assessing its absorption performance in this frequency band at millikelvin temperature. A lumped-element inductor based on a 4th order Hilbert structure is designed to absorb the incoming radiation in two orthogonal linear polarizations. The development of a large-format camera prototype is presented. On one hand, ambient temperature quasi-optical characterization demonstrates a suitable absorption for both polarizations within the W-band. On the other hand, dark cryogenic characterization confirms the successful operation of the multiplexed KID devices providing high-quality factors and an operation yield of 97%. These results confirm these developments to be used in future polarimeter receivers.

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jun 14, 2024•0 citations

Ultra high quality factor resonators for kinetic inductance detectors

G. Hammer, S. Wünsch, K. Ilin +1 more

The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.

Journal of Physics Conference Series•Feb 1, 2008•12 citations

Realization of the Resonant Cold-Electron Bolometer With a Kinetic Inductance Nanofilter for Multichroic Pixels

L. S. Kuzmin, Anton S. Mukhin, Alexander V. Chiginev

A novel type of the resonant cold-electron bolometer (RCEB) has been realized for multichroic pixels. The internal resonance is organized by a kinetic inductance of the NbN superconducting nanostrip and a capacitance of the superconductor-insulator-normal (SIN) tunnel junctions. The basic idea of a multichroic system is to combine a wideband antenna and narrow-band RCEBs. We used a single Lambda slot with two RCEBs for 75 and 105 GHz, placed in the middle. Each RCEB included two SIN junctions with absorber connected to NbN kinetic inductance of 420 and 240 pH. SIN junctions had capacitances of 11 and 8 fF. Wave impedance of the slot antenna was near 15 Ω and resistance of the absorber was matched to this value. Matching of antenna with an external system was done by placing Si lens on the back side of a Si substrate. RF testing was done at 300 mK irradiating this chip by sweep generator from 60 to 120 GHz. The response curves showed clear resonances at 75 and 105 GHz with quality factor of 10 and 7. Kinetic inductance value was estimated at the level of 35 pH/sq. These experiments confirmed that the RCEB can be effectively used to create multiband elements.

IEEE Transactions on Applied Superconductivity•Mar 6, 2018•3 citations
This article presents a multichroic Kinetic Inductance Bolometer (KIB) polarimeter that utilizes coplanar waveguide (CPW) diplexers. The CPW diplexers function as filters, providing two passbands centered at 220 GHz and 280 GHz. The high-quality-factor resonant units deliver excellent transmission and isolation characteristics. Additionally, the quasi-lumped-element resonator design enables a significant reduction in size compared to conventional microstrip diplexers. The entire polarimeter—comprising orthomode transducer (OMT) probes, diplexers, KIBs, and CPW feed lines—is integrated on a single plane, allowing for one-layer superconducting thin-film fabrication with a simplified process. The compact size, superior frequency response, and streamlined fabrication process make the proposed pixel scheme suitable for integrated array development.
The design of a diplexer, coupled to a planar bowtie antenna for two-band Cosmic Microwave Background detection is proposed, using both HFSS™ and ADS™ softwares. The two photometric bands are centered on 150 GHz and 220 GHz respectively. The diplexer is composed of two three-elements distributed filtering circuits, taking into account the complex impedance of the antenna and the impedance of the two resistive loading bolometers. The distributed elements are transmission lines Coplanar Strip Lines (CPS) and Broadside Coupled Lines (BCL). Their balanced geometry matches to the differential signal delivered by the bow-tie antenna, avoiding the addition of a balun circuit. The envisaged technology for strips and antenna is superconducting niobium at a few 100mK on Si substrate. The overall size of the antenna/diplexer structure is around 2 mm2, allowing to consider it as a pixel suitable for integration in a bolometer array.
Cosmic microwave background (CMB) studies require observations in several frequency bands simultaneously. For example, the detection of clusters of remote galaxies can be performed by comparing CMB photon fluxes at different frequencies, using the spectral deformation of the Planck law, due to the Sunyaev–Zeldovich effect. We propose a single pixel design to receive and detect simultaneously two frequency bands of the (CMB), centered at 150 and 220 GHz. It is composed of a bow-tie antenna, sensitive to the polarization of the incident radiation, feeding a diplexer structure to separate the signal towards two kinetic inductance resonators associated respectively with the 130–170 and 200–270 GHz frequency bands. The diplexer makes use of 150 nm thick niobium-based superconducting transmission lines of the coplanar strip-lines (CPS) type, for filtering and separation purposes, deposited on a 30 μm thick quartz substrate. A new coplanar matching structure, taking into account the kinetic inductance of the superconducting films, is proposed and achieves a nearly perfect match over more than 25% of each frequency band, along with a signal separation ratio above 30 dB at both center frequencies. The size of a single pixel is 0.9 mm × 1.2 mm.
We propose a pixel design, aimed to be included in an array, receiving and de- tecting simultaneously two bands of the Cosmic Microwave Background (CMB). It is composed of a bowtie antenna, feeding a diplexer structure to separate the signal towards two bolomet- ric detectors at 150 and 220GHz. The diplexer makes use of difierential transmission lines of Coplanar Striplines (CPS) and Broadside Coupled Lines (BCL) types, for flltering and separation purposes. The antenna and diplexer are planned to be fabricated in a superconductive niobium thin fllm deposited on a Silicon substrate, while NbSi bolometers will lie on a SiN membrane. The device has been simulated by means of ADS (Agilent), CST Microwave Studio and HFSS (Ansoft) softwares. Final dimensions that take into account the kinetic inductance of the super- conducting lines are proposed. Promising computation results are found, with signal separation up to 20dB.
This work deals with the development of superconducting Kinetic Inductance Detectors (KIDs) for highly sensitive radio astronomy receivers within W-band (75 to 110 GHz). A bilayer based on superconducting titanium/aluminum (Ti/Al) thin films has been used for assessing its absorption performance in this frequency band at millikelvin temperature. A lumped-element inductor based on a 4th order Hilbert structure is designed to absorb the incoming radiation in two orthogonal linear polarizations. The development of a large-format camera prototype is presented. On one hand, ambient temperature quasi-optical characterization demonstrates a suitable absorption for both polarizations within the W-band. On the other hand, dark cryogenic characterization confirms the successful operation of the multiplexed KID devices providing high-quality factors and an operation yield of 97%. These results confirm these developments to be used in future polarimeter receivers.
The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.
A novel type of the resonant cold-electron bolometer (RCEB) has been realized for multichroic pixels. The internal resonance is organized by a kinetic inductance of the NbN superconducting nanostrip and a capacitance of the superconductor-insulator-normal (SIN) tunnel junctions. The basic idea of a multichroic system is to combine a wideband antenna and narrow-band RCEBs. We used a single Lambda slot with two RCEBs for 75 and 105 GHz, placed in the middle. Each RCEB included two SIN junctions with absorber connected to NbN kinetic inductance of 420 and 240 pH. SIN junctions had capacitances of 11 and 8 fF. Wave impedance of the slot antenna was near 15 Ω and resistance of the absorber was matched to this value. Matching of antenna with an external system was done by placing Si lens on the back side of a Si substrate. RF testing was done at 300 mK irradiating this chip by sweep generator from 60 to 120 GHz. The response curves showed clear resonances at 75 and 105 GHz with quality factor of 10 and 7. Kinetic inductance value was estimated at the level of 35 pH/sq. These experiments confirmed that the RCEB can be effectively used to create multiband elements.