Design, Assembly and Geometric Characterization of Linear Paul Trap using Solidworks, Microscope, and Collimated Laser Beam

Naleli Jubert Matjelo, Ncamiso B. Khanyile

Published May 27, 2021• 0 citations
Publisher

Abstract

In this paper, the schematics of a linear Paul trap, designed using Solid works are presented. A careful procedure followed during electrode alignment, under the microscope, is discussed in detail. The assembled linear Paul trap is then characterized using a collimated 369 nm laser beam and the results are presented, analyzed, and discussed. The trap geometric parameters found in this work help guide the trap compensation with static potentials and characterization ofthe stability diagram of the ion trap.

DOI
10.21275/mr21513050603

Related papers

Design and implementation of a blade-type linear Paul trap

Lautaro Ezequiel Filgueira, Marcelo Alejandro Luda, Christian Tomás Schmiegelow

In this work, we present the design, construction, and characterization of a linear Paul trap in a blade configuration. The trap was optimized to minimize micromotion and enable the formation of linear ion chains comprising tens of ions. We discuss the design requirements for low axial micromotion and reduced capacitance and describe the simulation and optimization of the trap design parameters. The assembled trap is characterized through direct measurements of the axial and radial confinement frequencies using the tickling method. We identify deviations from the target design due to manufacturing tolerances and present a compensation procedure to calibrate and correct for these effects.

arXiv:2504.15368•AIP Advances•Oct 1, 2025•1 citation

Influence of End Cap Structure on the Axial Geometric Parameter of the Linear Paul Trap

Lin Li, Zi Li

Through finite-element simulation, the axial potential distribution of the ion trap is analyzed. The effects of the central hole diameter of the end cap and the spacing between the two end caps on the axial geometric parameters of the ion trap are investigated. Based on these findings, a set of linear Paul traps is designed by selecting suitable end caps and quadrupoles. Stable trapping of calcium ions (Ca+) is successfully achieved, and these ions are subsequently laser-cooled into ionic Coulomb crystals. In the experiment, secular motion excitation of the Ca+ ion Coulomb crystal is performed, yielding an axial geometric parameter of 0.115(1) for the ion trap. This value aligns well with the simulation result of 0.114(2). The precise determination of the axial geometric parameter provides a solid foundation for subsequent high-precision optical or mass spectrometry measurements.

Atoms•Feb 5, 2026•2 citations

Determination of the geometric parameters and of a linear Paul trap

H.X. Li, Yi Zhang, Shuxian He +1 more

An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).

Chinese Journal of Physics•May 1, 2019•14 citations

Design and Characteristic Measurement of Miniature Three-Segment Linear Paul Trap

T. Furukawa, Jin Nishimura, U. Tanaka +1 more

We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.

Japanese Journal of Applied Physics•Oct 1, 2005•10 citations

Ion Trapping with a Laser-written 3D Miniaturized Monolithic Linear Paul Trap for Microcavity Integration

Teh, Soon, Kassa, Ezra, Gao, Shaobo +2 more

The miniaturization of ion trap and the precise placement of its electrodes are necessary for the integration of a microcavity to facilitate efficient ion-cavity coupling. We present a miniature monolithic ion trap made of gold-coated fused silica with high numerical aperture access. A laser writing method referred to as selective laser etching is employed to extract a trap structure from a block of fused silica. The fully monolithic structure eliminates the need for any post-fabrication alignment. Trenches are integrated into this structure such that the various electrodes on the monolithic device remain electrically isolated following their metalization via evaporative coating. We give details of the trap design and production, along with the demonstration of successful trapping of ions and characerization of the trap.

arXiv:2409.05075•Sep 8, 2024•5 citations

Surface-electrode point Paul trap

Tony Hyun Kim, Peter F. Herskind, Taehyun Kim +2 more

We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single $^{88}\mathrm{Sr}$${}^{+}$ ions over an ion height range of $200\ensuremath{-}1000$ $\ensuremath{\mu}$m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.

arXiv:1008.1603•Physical Review A•Oct 12, 2010•43 citations
In this paper, the schematics of a linear Paul trap, designed using Solid works are presented. A careful procedure followed during electrode alignment, under the microscope, is discussed in detail. The assembled linear Paul trap is then characterized using a collimated 369 nm laser beam and the results are presented, analyzed, and discussed. The trap geometric parameters found in this work help guide the trap compensation with static potentials and characterization ofthe stability diagram of the ion trap.
In this work, we present the design, construction, and characterization of a linear Paul trap in a blade configuration. The trap was optimized to minimize micromotion and enable the formation of linear ion chains comprising tens of ions. We discuss the design requirements for low axial micromotion and reduced capacitance and describe the simulation and optimization of the trap design parameters. The assembled trap is characterized through direct measurements of the axial and radial confinement frequencies using the tickling method. We identify deviations from the target design due to manufacturing tolerances and present a compensation procedure to calibrate and correct for these effects.
Through finite-element simulation, the axial potential distribution of the ion trap is analyzed. The effects of the central hole diameter of the end cap and the spacing between the two end caps on the axial geometric parameters of the ion trap are investigated. Based on these findings, a set of linear Paul traps is designed by selecting suitable end caps and quadrupoles. Stable trapping of calcium ions (Ca+) is successfully achieved, and these ions are subsequently laser-cooled into ionic Coulomb crystals. In the experiment, secular motion excitation of the Ca+ ion Coulomb crystal is performed, yielding an axial geometric parameter of 0.115(1) for the ion trap. This value aligns well with the simulation result of 0.114(2). The precise determination of the axial geometric parameter provides a solid foundation for subsequent high-precision optical or mass spectrometry measurements.
An effective method for determining the geometric parameters of a linear Paul trap is provided and carried out in this paper. The method is based on exciting the secular motion of laser-cooled Ca+ ions in a linear Paul trap with varied trapping potentials. Taking advantage of the segmented structure of the linear Paul trap, both the axial and the radial geometric parameters are obtained by applying external excitation fields to the trapping electrodes directly. The axial geometric parameter of our linear Paul trap is determined to be 0.374(3), and, for the first time, the radial geometric parameter is determined to be 0.928(2).
We have fabricated a miniature three-segment linear Paul trap with r 0=0.6 mm and 2Z 0=4 mm. In order to perform quantum-state manipulation of trapped 40 Ca+ ions, we discuss the required harmonic oscillation frequencies which allow us to perform effective sideband cooling and have measured those that depend on the dimensions of the trap. A laser beam that has a component in the radial direction of the linear trap as well as that propagating along the trap axis has been used to detect the fluorescence spectra of the 42 S 1/2–42 P 1/2 transition. We have observed that the profile of the fluorescence spectrum obtained with the side laser beam is markedly different from that obtained with the axial laser beam due to micromotion. By applying additional DC voltages, the micromotion has been compensated, its amplitude has been estimated, and crystallization has been observed for two 40 Ca+ and four 40 Ca+ ions.
The miniaturization of ion trap and the precise placement of its electrodes are necessary for the integration of a microcavity to facilitate efficient ion-cavity coupling. We present a miniature monolithic ion trap made of gold-coated fused silica with high numerical aperture access. A laser writing method referred to as selective laser etching is employed to extract a trap structure from a block of fused silica. The fully monolithic structure eliminates the need for any post-fabrication alignment. Trenches are integrated into this structure such that the various electrodes on the monolithic device remain electrically isolated following their metalization via evaporative coating. We give details of the trap design and production, along with the demonstration of successful trapping of ions and characerization of the trap.
We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single 88Sr^{88}\mathrm{Sr}88Sr+{}^{+}+ ions over an ion height range of $200\ensuremath{-}1000$ $\ensuremath{\mu}$m for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model.