Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Charge-Based Single-Shot Readout Systems in Quantum Computing

Conor Power, Robert Bogdan Staszewski, Elena Blokhina

Published Nov 27, 2024• 0 citations
Publisher

Abstract

Measurement of a qubit (quantum bit) is a key element of quantum computation and is necessary for extracting information from a quantum processor. The physical implementation of a measurement protocol involves monitoring a physical quantity of a sensor, such as a current or a voltage, that is correlated with the state of the qubit to be measured. The monitoring of these sensors used to measure qubits in modern quantum computer architectures is typically divided between RF reflectometry and current/voltage monitoring. There are tradeoffs involved with both approaches for the reliable and accurate readout of qubits when it comes to scalable quantum computing architectures. In this article, we will review the working principles of a selection of sensors that are used to measure the state of qubits in semiconductors. The goal is to introduce electronic engineers with little or no background in quantum computing to the working principles of charge sensors in semiconductor quantum computers, their identification in various physical systems, and an overview of their design tradeoffs when measuring a qubit. This will allow electronic engineers to begin working with physics literature in the field of charge sensing. An overview of the article and the topics that will be discussed is given in Fig. 5.

DOI
10.36227/techrxiv.173272650.09950924/v1

Related papers

Charge-Based Single-Shot Readout Systems in Quantum Computing [Feature]

Conor Power, Robert Bogdan Staszewski, Elena Blokhina

Measurement of a qubit (quantum bit) is a key element of quantum computation and is necessary for extracting information from a quantum processor. The physical implementation of a measurement protocol involves monitoring a physical quantity of a sensor, such as a current or a voltage, that is correlated with the state of the qubit to be measured. The monitoring of these sensors used to measure qubits in modern quantum computer architectures is typically divided between RF reflectometry and current/voltage monitoring. There are tradeoffs involved with both approaches for the reliable and accurate readout of qubits when it comes to scalable quantum computing architectures. In this article, we will review the working principles of a selection of sensors that are used to measure the state of qubits in semiconductors. The goal is to introduce electronic engineers with little or no background in quantum computing to the working principles of charge sensors in semiconductor quantum computers, their identification in various physical systems, and an overview of their design tradeoffs when measuring a qubit. This will allow electronic engineers to begin working with physics literature in the field of charge sensing.

IEEE Circuits and Systems Magazine•Jan 1, 2024•4 citations

DC-Readout of Semiconductor Spin Qubits: Opportunities and Limits

Gerd Kiene, Oriol Pietx-Casas, Masoud Babaie +2 more

This paper presents extensive guidelines for the design of an integrated DC-readout interface for semiconductor spin qubits. Since the focus is on the readout via a single electron transistor (SET), the SET behavior and performance are first described and modeled, showing that the signal-to-noise ratio (SNR) theoretically achievable by a SET-based DC-readout is significantly beyond the state-of-the-art. Practical circuit architectures for implementing a DC-readout, such as the voltage amplifier, the transimpedance amplifier, the charge sampling, and the current pre-amplifier, are then analyzed by deriving their design equations and trade-offs. As a result, the practical performances of those different solutions are evaluated and compared, thus presenting clear selection criteria for the readout architecture and its design equations given the specific parameters of the SET sensor.

IEEE Transactions on Circuits and Systems I Regular Papers•Feb 19, 2025•5 citations

Real-Time Feedback Control of Charge Sensing for Quantum Dot Qubits

Takashi Nakajima, Yohei Kojima, Yoshihiro Uehara +4 more

Measuring electrical charge with single-electron resolution is essential for implementing spin qubits in semiconductor quantum dots. Applying quantum dot charge sensors in larger-scale quantum computing devices is being held back because these sensors are easily affected by environmental disturbances, and thus require elaborate tune-up. This study uses a feedback control circuit implemented on a field-programmable gate array to maintain sensor performance in the face of capacitive crosstalk and charge noise. The technique enables rapid tune-up of quantum dot devices and reliable single-shot electron or spin measurement, and will advance the development of large-scale spin-qubit devices.

arXiv:2103.15258•Physical Review Applied•Mar 26, 2021•28 citations

Radio-Frequency Capacitive Gate-Based Sensing

Imtiaz Ahmed, J. A. Haigh, Simon Schaal +8 more

Quantum computation requires a qubit-specific measurement capability to read out the final states of individual qubits. Promising semiconductor architectures use external readout electrometers, but these could be replaced by more scalable $g\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}e$ $s\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}s\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}s$, based on the dispersive coupling between an electrical resonator and the qubit. The authors present an optimized gate sensor and show that significantly better sensitivity arises from changing circuit topology to enhance the resonator's $Q$ factor. Here CMOS-based quantum devices achieve charge sensitivity on par with that of the best single-electron electrometers.

arXiv:1801.09759•Physical Review Applied•Jul 19, 2018•79 citations

Benchmarking high fidelity single-shot readout of semiconductor qubits

Daniel Keith, Samuel Keith Gorman, Ludwik Kranz +4 more

Abstract Determination of qubit initialisation and measurement fidelity is important for the overall performance of a quantum computer. However, the method by which it is calculated in semiconductor qubits varies between experiments. In this paper we present a full theoretical analysis of electronic single-shot readout and describe critical parameters to achieve high fidelity readout. In particular, we derive a model for energy selective state readout based on a charge detector response and examine how to optimise the fidelity by choosing correct experimental parameters. Although we focus on single electron spin readout, the theory presented can be applied to other electronic readout techniques in semiconductors that use a reservoir.

arXiv:1811.03630•New Journal of Physics•May 23, 2019•55 citations

Probing the limits of gate-based charge sensing

M. Fernando González-Zalba, Sylvain Barraud, Andrew J. Ferguson +1 more

Quantum computation requires a qubit-specific measurement capability to readout the final state of individual qubits. Promising solid-state architectures use external readout electrometers but these can be replaced by a more compact readout element, an in situ gate sensor. Gate-sensing couples the qubit to a resonant circuit via a gate and probes the qubit’s radiofrequency polarizability. Here we investigate the ultimate performance of such a resonant readout scheme and the noise sources that limit its operation. We find a charge sensitivity of 37 μe Hz−1/2, the best value reported for this technique, using the example of a gate sensor strongly coupled to a double quantum dot at the corner states of a silicon nanowire transistor. We discuss the experimental factors limiting gate detection and highlight ways to optimize its sensitivity. In total, resonant gate-based readout has advantages over external electrometers both in terms of reduction of circuit elements as well as absolute charge sensitivity. Reading out the state of quantum bits is an essential requirement that any quantum computer implementation must satisfy. Gonzalez-Zalba et al. now show that in situresonant gate-based detection can be a more sensitive approach than external electrometers while reducing the qubit architecture’s complexity.

arXiv:1405.2755•Nature Communications•Jan 20, 2015•177 citations
Measurement of a qubit (quantum bit) is a key element of quantum computation and is necessary for extracting information from a quantum processor. The physical implementation of a measurement protocol involves monitoring a physical quantity of a sensor, such as a current or a voltage, that is correlated with the state of the qubit to be measured. The monitoring of these sensors used to measure qubits in modern quantum computer architectures is typically divided between RF reflectometry and current/voltage monitoring. There are tradeoffs involved with both approaches for the reliable and accurate readout of qubits when it comes to scalable quantum computing architectures. In this article, we will review the working principles of a selection of sensors that are used to measure the state of qubits in semiconductors. The goal is to introduce electronic engineers with little or no background in quantum computing to the working principles of charge sensors in semiconductor quantum computers, their identification in various physical systems, and an overview of their design tradeoffs when measuring a qubit. This will allow electronic engineers to begin working with physics literature in the field of charge sensing. An overview of the article and the topics that will be discussed is given in Fig. 5.
Measurement of a qubit (quantum bit) is a key element of quantum computation and is necessary for extracting information from a quantum processor. The physical implementation of a measurement protocol involves monitoring a physical quantity of a sensor, such as a current or a voltage, that is correlated with the state of the qubit to be measured. The monitoring of these sensors used to measure qubits in modern quantum computer architectures is typically divided between RF reflectometry and current/voltage monitoring. There are tradeoffs involved with both approaches for the reliable and accurate readout of qubits when it comes to scalable quantum computing architectures. In this article, we will review the working principles of a selection of sensors that are used to measure the state of qubits in semiconductors. The goal is to introduce electronic engineers with little or no background in quantum computing to the working principles of charge sensors in semiconductor quantum computers, their identification in various physical systems, and an overview of their design tradeoffs when measuring a qubit. This will allow electronic engineers to begin working with physics literature in the field of charge sensing.
This paper presents extensive guidelines for the design of an integrated DC-readout interface for semiconductor spin qubits. Since the focus is on the readout via a single electron transistor (SET), the SET behavior and performance are first described and modeled, showing that the signal-to-noise ratio (SNR) theoretically achievable by a SET-based DC-readout is significantly beyond the state-of-the-art. Practical circuit architectures for implementing a DC-readout, such as the voltage amplifier, the transimpedance amplifier, the charge sampling, and the current pre-amplifier, are then analyzed by deriving their design equations and trade-offs. As a result, the practical performances of those different solutions are evaluated and compared, thus presenting clear selection criteria for the readout architecture and its design equations given the specific parameters of the SET sensor.
Measuring electrical charge with single-electron resolution is essential for implementing spin qubits in semiconductor quantum dots. Applying quantum dot charge sensors in larger-scale quantum computing devices is being held back because these sensors are easily affected by environmental disturbances, and thus require elaborate tune-up. This study uses a feedback control circuit implemented on a field-programmable gate array to maintain sensor performance in the face of capacitive crosstalk and charge noise. The technique enables rapid tune-up of quantum dot devices and reliable single-shot electron or spin measurement, and will advance the development of large-scale spin-qubit devices.
Quantum computation requires a qubit-specific measurement capability to read out the final states of individual qubits. Promising semiconductor architectures use external readout electrometers, but these could be replaced by more scalable $g\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}t\phantom{\rule{0}{0ex}}e$ $s\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}n\phantom{\rule{0}{0ex}}s\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}s$, based on the dispersive coupling between an electrical resonator and the qubit. The authors present an optimized gate sensor and show that significantly better sensitivity arises from changing circuit topology to enhance the resonator's QQQ factor. Here CMOS-based quantum devices achieve charge sensitivity on par with that of the best single-electron electrometers.
Abstract Determination of qubit initialisation and measurement fidelity is important for the overall performance of a quantum computer. However, the method by which it is calculated in semiconductor qubits varies between experiments. In this paper we present a full theoretical analysis of electronic single-shot readout and describe critical parameters to achieve high fidelity readout. In particular, we derive a model for energy selective state readout based on a charge detector response and examine how to optimise the fidelity by choosing correct experimental parameters. Although we focus on single electron spin readout, the theory presented can be applied to other electronic readout techniques in semiconductors that use a reservoir.
Quantum computation requires a qubit-specific measurement capability to readout the final state of individual qubits. Promising solid-state architectures use external readout electrometers but these can be replaced by a more compact readout element, an in situ gate sensor. Gate-sensing couples the qubit to a resonant circuit via a gate and probes the qubit’s radiofrequency polarizability. Here we investigate the ultimate performance of such a resonant readout scheme and the noise sources that limit its operation. We find a charge sensitivity of 37 μe Hz−1/2, the best value reported for this technique, using the example of a gate sensor strongly coupled to a double quantum dot at the corner states of a silicon nanowire transistor. We discuss the experimental factors limiting gate detection and highlight ways to optimize its sensitivity. In total, resonant gate-based readout has advantages over external electrometers both in terms of reduction of circuit elements as well as absolute charge sensitivity. Reading out the state of quantum bits is an essential requirement that any quantum computer implementation must satisfy. Gonzalez-Zalba et al. now show that in situresonant gate-based detection can be a more sensitive approach than external electrometers while reducing the qubit architecture’s complexity.