Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement

Suppression of spin-exchange relaxation in Bell-Bloom magnetometer

Chi Fang, Liwei Jiang, Jiali Liu, Yuanqiang Chen, Jun Zhu, Qi Shao, Yuntian Zou, Min Xiang, Wei Quan

Published Sep 10, 2024• 14 citations
Publisher
DOI
10.1016/j.measurement.2024.115695

Related papers

Sensitivity optimization of Bell-Bloom magnetometers by manipulation of atomic spin synchronization

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi +1 more

Physica C Superconductivity•Mar 5, 2018•3 citations

Vectorial Bell-Bloom atomic magnetometer using spin procession modulation

Haichao Huang, Xuyang Hu, Haifeng Dong

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

Linear and nonlinear coherent coupling in a Bell-Bloom magnetometer

R. Gartman, Vera Guarrera, G. Bevilacqua +1 more

Spin-exchange collisions in hot vapors are generally regarded as a decoherence mechanism. In contrast, we show that linear and nonlinear spin-exchange coupling can lead to the generation of atomic coherence in a Bell-Bloom magnetometer. In particular, we theoretically and experimentally demonstrate that nonlinear spin-exchange coupling, acting in an analogous way to a wave-mixing mechanism, can create additional modes of coherent excitation which inherit the magnetic properties of the natural Larmor coherence. The generated coherences further couple via linear spin-exchange interaction, leading to an increase of the natural coherence lifetime of the system. Notably, the measurements are performed in a low-density caesium vapor and for nonzero magnetic field, outside the standard conditions for collisional coherence transfer. The strategies discussed are important for the development of spin-exchange coupling into a resource for an improved measurement platform based on room-temperature alkali-metal vapors.

arXiv:1903.05605•Physical Review A•Dec 13, 2018•7 citations

Signal-enhanced spin-exchange relaxation-free atomic magnetometer

Cao Li, Junjian Tang, Yaohua Zhang +4 more

Sensors and Actuators A Physical•Feb 16, 2023•20 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•7 citations

Active magnetic compensation of spin-exchange-relaxation-free atomic magnetometer

楚中毅 CHU Zhong-yi, 孙晓光 SUN Xiao-guang, 万双爱 WAN Shuang-ai +1 more

Optics and Precision Engineering•Jan 1, 2014•2 citations
Spin-exchange collisions in hot vapors are generally regarded as a decoherence mechanism. In contrast, we show that linear and nonlinear spin-exchange coupling can lead to the generation of atomic coherence in a Bell-Bloom magnetometer. In particular, we theoretically and experimentally demonstrate that nonlinear spin-exchange coupling, acting in an analogous way to a wave-mixing mechanism, can create additional modes of coherent excitation which inherit the magnetic properties of the natural Larmor coherence. The generated coherences further couple via linear spin-exchange interaction, leading to an increase of the natural coherence lifetime of the system. Notably, the measurements are performed in a low-density caesium vapor and for nonzero magnetic field, outside the standard conditions for collisional coherence transfer. The strategies discussed are important for the development of spin-exchange coupling into a resource for an improved measurement platform based on room-temperature alkali-metal vapors.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.