Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Diamond Quantum Magnetic Sensor toward a Precision Comparison of Currents with a Current Comparator

Hidekazu Muramatsu, Yuta Kainuma, Yuji Hatano, Yasutaka Amagai, Hiromitsu Kato, Norihiko Sakamoto, Tatsuji Yamada, Chiharu Urano, Nobu‐Hisa Kaneko, Hiroshi Abe, Shinobu Onoda, Takeshi Ohshima, Mutsuko Hatano, Takayuki Iwasaki

Published Jul 8, 2024• 3 citations
Publisher

Abstract

In this paper, a diamond nitrogen-vacancy (NV) magnetic sensor toward a precision comparison of currents with a current comparator is described. A diamond quantum sensor can sensitively detect magnetic fields based on the Zeeman effect of the electron spin state of NV centers, which may be used as a detector in a current comparator. The compact diamond quantum sensor head has been developed, being capable of positioning in an air gap formed in a ring-shaped magnetic core. The sensor exhibited the DC magnetic noise floor of less than $100\,{\text{pT}}/\sqrt {{\text{Hz}}} $. The obtained magnetic noise floor is less than equivalent current noise level required for a current comparator.

DOI
10.1109/cpem61406.2024.10646090

Related papers

Highly sensitive diamond quantum sensor with large sensor volume toward magnetoencephalography

雄太 増山, Takayuki Iwasaki, 睦子 波多野 +4 more

Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.

•Dec 4, 2019•0 citations

New Quantum Sensing Modalities of Nitrogen-Vacancy Centers

Qiu, Ziwei

The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.

•Jan 1, 2022•0 citations

Research on DC Current Measurement Method based on Solid-state Quantum

Mingyang Liu, Changkui Wang, Xiaofei Li +2 more

The research focuses on the solid-state spin system of diamond NV (Negatively Charged Nitrogen Vacancy, NV) color centers, which exhibit excellent optical readout, polarization properties, and millisecond-scale coherent time. This makes it an important means to achieve quantum information processing and quantum precision measurement. Additionally, its ultrahigh sensitivity to magnetic fields provides a potential path for diamond’s high-precision current measurement. This paper investigates a reliable method in the field of direct current measurement using quantum sensing technology based on diamond NV color centers. It involves measuring the change in the optically detected magnetic resonance spectrum based on a fixed microwave frequency to achieve magnetic field measurement. Simultaneously, by utilizing the spatial distribution of magnetic sensor heads, it achieves current inversion. Finally, an experimental platform was constructed for validation. Preliminary results indicate that the linear fit error for direct current amplitude is less than 10^-7, confirming the feasibility of this technological approach and providing a potential application for diamond in measuring currents in power systems.

IEEE International Conference on Internet of Things (iThings) and IEEE Green Computing and Communications (GreenCom) and IEEE Cyber, Physical and Social Computing (CPSCom) and IEEE Smart Data (SmartData)•Dec 17, 2023•1 citation

Improved sensitivity to magnetic fields by rotation of quantum sensors

A. A. Wood, A. G. Aeppli, Emmanuel Lilette +5 more

Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a $1/f$ dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time $T_2^*$, the relevant sensing time for a DC field, being much lower than the spin coherence time $T_2$, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, $T_2$. We rotate the host diamond with a period comparable to $T_2$, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.

•Feb 12, 2018•0 citations

Implementation of digital filtering detection method for portable highly sensitive quantum diamond magnetometer

Y. MASUYAMA, Takayuki Iwasaki, Mutsuko Hatano +1 more

One of the promising solid-state quantum sensors is nitrogen-vacancy (NV) centers in diamond which can maintain quantum state at room temperature and under atmospheric pressure condition. Further improvement of sensitivity of the sensor is needed to detect the magnetic field from the brain. Noise reduction and simplified system are key techniques especially for the practical use of highly sensitive DC magnetic sensor. In this study, we devised a digital filtering detection method without synchronization between detector and modulator which is a similar noise reduction effect as a lock-in detection technique. We implemented the detection method for the quantum diamond sensor system with the large sensor volume [1]. The Lock-in detection technique is a typical high sensitivity technique for DC magnetic measurement. There are several different implementations of lock-in detection technique for the quantum diamond sensor including microwave modulation, magnetic field modulation, and laser modulation. However, it is a challenging task to obtain high magnetic sensitivity with a compact sensor module because these lock-in detection techniques require a lock-in amplifier or synchronization system. We devised a digital filtering detection method which is an alternative method to the lock-in detection technique. Fluorescence from the NV center is modulated by frequency modulated microwave during optical detected magnetic resonance (ODMR) measurement. The fluorescence is analyzed by digital signal processing which achieves a similar noise reduction effect as a lock-in detection technique. Our method relies on a fact that ODMR converts frequency modulation to amplitude modulation. Thus, our method is applicable not only to the NV center system but also another color center system. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Y. Masuyama et al., Rev. Sci. Instrum. 89, 125007 (2018).

•Jun 4, 2019•0 citations

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation
In this paper, a diamond nitrogen-vacancy (NV) magnetic sensor toward a precision comparison of currents with a current comparator is described. A diamond quantum sensor can sensitively detect magnetic fields based on the Zeeman effect of the electron spin state of NV centers, which may be used as a detector in a current comparator. The compact diamond quantum sensor head has been developed, being capable of positioning in an air gap formed in a ring-shaped magnetic core. The sensor exhibited the DC magnetic noise floor of less than 100 pT/Hz100\,{\text{pT}}/\sqrt {{\text{Hz}}} 100pT/Hz​. The obtained magnetic noise floor is less than equivalent current noise level required for a current comparator.
Nitrogen-vacancy (NV) color centers in diamond are promising solid-state quantum sensors working at room temperature. The number of NV centers limits the magnetic sensitivity of the quantum magnetometer. Increasing the number of NV centers is a challenging task due to technical issues such as microwave power density, detection noise.Here, we developed the sensor system with a large detection volume which contains a lot of NV centers. The microwave circuit enhances microwave power density. Digital filter with frequency modulation of microwave allows us to detect the magnetic field with low noise. Consequently, we obtained a DC magnetic field sensitivity of 980 pT/√Hz.This work was supported by MEXT Quantum Leap Flagship Program (MEXT Q-LEAP) Grant Number JPMXS0118067395.
The recent decade has witnessed exciting developments in quantum science and technology. Quantum sensing is a rapidly growing branch, which exploits the fragility of quantum systems to detect small external signals. The extreme control at the single-atom level and the remarkably long coherence time of engineered quantum systems enable unprecedented sensitivity and precision, beating the performance of classical techniques. The nitrogen-vacancy (NV) center in diamond is one of the most promising quantum sensors. Its unique advantages have attracted considerable attention, including a long spin coherence time throughout a broad temperature range, nanoscale resolution limited by the sensor-sample distance, convenient optical control of its spin states and remarkably versatile sensing capabilities. Its properties are well studied under a bias magnetic field oriented along its quantization axis. However, its sensing capabilities in the presence of an off-axis magnetic field are much less explored. My research aims to unlock the full potential of NV quantum sensor by developing new sensing modalities under a magnetic field acting perpendicular to the NV axis, and furthermore, integrating them into a scanning probe microscope. In this dissertation, I will report our progress toward building a scanning NV multimodal quantum imaging platform, which will open up exciting opportunities in measuring nanoscale phenomena. The first chapter provides an introduction to the background of quantum sensing with NV centers, followed by a discussion on its basic properties and established sensing techniques. The second and third chapters are dedicated to two experiments performed under a perpendicular magnetic field where traditional NV magnetometry based on the Zeeman effect fails. In the second chapter, I will introduce a new sensing strategy that uses the entanglement between the electron and nuclear spins to restore the magnetic field sensitivity under this unfavored condition. This allows us to sense small changes in the magnetic field angle relative to the NV axis, and to detect anisotropic magnetic noise in the local environment. In the third chapter, I will present our latest development of scanning NV electrometry, where a single NV at the apex of a diamond scanning probe images external alternating (AC) and direct (DC) electric fields with sub-100 nm resolution. In the last chapter, I will discuss our efforts on four experiments that were left unfinished. I will present the results we have achieved, analyze the challenges that we faced and propose potential solutions to overcome them.
The research focuses on the solid-state spin system of diamond NV (Negatively Charged Nitrogen Vacancy, NV) color centers, which exhibit excellent optical readout, polarization properties, and millisecond-scale coherent time. This makes it an important means to achieve quantum information processing and quantum precision measurement. Additionally, its ultrahigh sensitivity to magnetic fields provides a potential path for diamond’s high-precision current measurement. This paper investigates a reliable method in the field of direct current measurement using quantum sensing technology based on diamond NV color centers. It involves measuring the change in the optically detected magnetic resonance spectrum based on a fixed microwave frequency to achieve magnetic field measurement. Simultaneously, by utilizing the spatial distribution of magnetic sensor heads, it achieves current inversion. Finally, an experimental platform was constructed for validation. Preliminary results indicate that the linear fit error for direct current amplitude is less than 10^-7, confirming the feasibility of this technological approach and providing a potential application for diamond in measuring currents in power systems.
Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a 1/f1/f1/f dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time T2∗T_2^*T2∗​, the relevant sensing time for a DC field, being much lower than the spin coherence time T2T_2T2​, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, T2T_2T2​. We rotate the host diamond with a period comparable to T2T_2T2​, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.
One of the promising solid-state quantum sensors is nitrogen-vacancy (NV) centers in diamond which can maintain quantum state at room temperature and under atmospheric pressure condition. Further improvement of sensitivity of the sensor is needed to detect the magnetic field from the brain. Noise reduction and simplified system are key techniques especially for the practical use of highly sensitive DC magnetic sensor. In this study, we devised a digital filtering detection method without synchronization between detector and modulator which is a similar noise reduction effect as a lock-in detection technique. We implemented the detection method for the quantum diamond sensor system with the large sensor volume [1]. The Lock-in detection technique is a typical high sensitivity technique for DC magnetic measurement. There are several different implementations of lock-in detection technique for the quantum diamond sensor including microwave modulation, magnetic field modulation, and laser modulation. However, it is a challenging task to obtain high magnetic sensitivity with a compact sensor module because these lock-in detection techniques require a lock-in amplifier or synchronization system. We devised a digital filtering detection method which is an alternative method to the lock-in detection technique. Fluorescence from the NV center is modulated by frequency modulated microwave during optical detected magnetic resonance (ODMR) measurement. The fluorescence is analyzed by digital signal processing which achieves a similar noise reduction effect as a lock-in detection technique. Our method relies on a fact that ODMR converts frequency modulation to amplitude modulation. Thus, our method is applicable not only to the NV center system but also another color center system. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Y. Masuyama et al., Rev. Sci. Instrum. 89, 125007 (2018).
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.