Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics D Applied Physics

A 85Rb transverse modulation magnetometer in the geophysical range based on atomic alignment states

Tao Shi, Ge Jin, Hong Lin Zhang, Sheng Zou

Published Aug 22, 2024• 2 citations
Publisher

Abstract

Abstract We have constructed a transverse modulated magnetometer based on spin alignment in a paraffin-coated 85 Rb cell operated in a geophysical magnetic field of 47.1 µT. When an orthogonal driving magnetic field ( x ^ axis) is resonant on the Larmor frequency ( z ^ axis), we have proposed a new method to zero the static residual magnetic fields in the transverse plane and achieved a sensitivity of 1.8 pT Hz − 1 with bandwidth of 200 Hz. The repump light ( F g = 2 → F e = 2 ) redistributes the populations in the ground state, rendering the state | F g = 2 ⟩ dark. This effect significantly amplifies the optical rotation signals nearly fourfold. The numerical solution of the Liouville equation is in good agreement with the experimental results. By using perturbation treatment and employing appropriate approximations, the derived analytical expressions for optical rotation are deduced to succinctly elucidate the dynamics of atomic alignment under parametric modulation. These outcomes could be extended for the advancement of an alignment magnetometer that has been designed to detect a weak magnetic signal in the geophysical range.

DOI
10.1088/1361-6463/ad726f

Related papers

High-order magnetic resonance in the presence of strong longitudinal radio-frequency magnetic field based on atomic alignment states

Tao Shi, Ge Jin, Sheng Zou

A longitudinal radio-frequency (rf) magnetic field resonating at the Larmor frequency along the $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{z}$ direction in the presence of a static transverse magnetic field s investigated. Optical-radio-frequency double resonance in $^{85}\mathrm{Rb}$ characterizes the strength of an external magnetic field through the precession frequency of $^{85}\mathrm{Rb}$ atoms. The measurements are carried out in a paraffin-coated $^{85}\mathrm{Rb}$ cell with a spin alignment configuration. An intriguing discovery of magnetic resonance peaks is observed at subharmonics of the Larmor frequency, accompanied by the emergence of nonlinear effects in the vicinity of the resonance. Notably, when the Larmor frequency reaches zero, the optical rotation signals induced by the rf magnetic field demonstrate a superposition of high-order harmonics of the rf frequency. Based on the simplified density matrix formalism and perturbation treatment, analytical expressions for the optical rotation are consistent with experimental outcomes. These findings hold the potential of extending our understanding on unveiling the dynamics of population and coherence among Zeeman sublevels, thereby advancing our knowledge in the field of alignment magnetometry.

Physical Review A•Apr 26, 2024•10 citations

Triaxial Alignment Magnetometer Utilizing Free-Spin Precession in the Geomagnetic Range

Jin, Ge, Tao Shi, Sheng Zou

In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 $μ{\text{T}}$ (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 ${\text{pT/}}\sqrt{\text{Hz}}$, 4.7 ${\text{pT/}}\sqrt{\text{Hz}}$, and 9.3 ${\text{pT/}}\sqrt{\text{Hz}}$ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.

arXiv:2502.11512•Feb 17, 2025•0 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•5 citations

Zero-field optical magnetometer based on spin alignment

Adil Meraki, L. Elson, N.J. Ho +4 more

Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

arXiv:2308.12233•Physical Review A•Dec 11, 2023•19 citations

Three-axis atomic magnetometer based on spin precession modulation

Hao Huang, Hai Feng Dong, Xiaofei Hu +2 more

We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.

Applied Physics Letters•Nov 2, 2015•63 citations

Detection of radio-frequency magnetic fields using nonlinear magneto-optical rotation

M. P. Ledbetter, Víctor M. Acosta, Simon Rochester +3 more

We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of $100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as $25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}$ (rms).

arXiv:physics/0609196•Physical Review A•Feb 8, 2007•66 citations
Abstract We have constructed a transverse modulated magnetometer based on spin alignment in a paraffin-coated 85 Rb cell operated in a geophysical magnetic field of 47.1 µT. When an orthogonal driving magnetic field ( x ^ axis) is resonant on the Larmor frequency ( z ^ axis), we have proposed a new method to zero the static residual magnetic fields in the transverse plane and achieved a sensitivity of 1.8 pT Hz − 1 with bandwidth of 200 Hz. The repump light ( F g = 2 → F e = 2 ) redistributes the populations in the ground state, rendering the state | F g = 2 ⟩ dark. This effect significantly amplifies the optical rotation signals nearly fourfold. The numerical solution of the Liouville equation is in good agreement with the experimental results. By using perturbation treatment and employing appropriate approximations, the derived analytical expressions for optical rotation are deduced to succinctly elucidate the dynamics of atomic alignment under parametric modulation. These outcomes could be extended for the advancement of an alignment magnetometer that has been designed to detect a weak magnetic signal in the geophysical range.
A longitudinal radio-frequency (rf) magnetic field resonating at the Larmor frequency along the $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{z}$ direction in the presence of a static transverse magnetic field s investigated. Optical-radio-frequency double resonance in 85Rb^{85}\mathrm{Rb}85Rb characterizes the strength of an external magnetic field through the precession frequency of 85Rb^{85}\mathrm{Rb}85Rb atoms. The measurements are carried out in a paraffin-coated 85Rb^{85}\mathrm{Rb}85Rb cell with a spin alignment configuration. An intriguing discovery of magnetic resonance peaks is observed at subharmonics of the Larmor frequency, accompanied by the emergence of nonlinear effects in the vicinity of the resonance. Notably, when the Larmor frequency reaches zero, the optical rotation signals induced by the rf magnetic field demonstrate a superposition of high-order harmonics of the rf frequency. Based on the simplified density matrix formalism and perturbation treatment, analytical expressions for the optical rotation are consistent with experimental outcomes. These findings hold the potential of extending our understanding on unveiling the dynamics of population and coherence among Zeeman sublevels, thereby advancing our knowledge in the field of alignment magnetometry.
In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 μTμ{\text{T}}μT (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​, 4.7 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​, and 9.3 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.
We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high-frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. Based on experimentally measured signal-to-noise ratio, we demonstrate a sensitivity of 100pG∕Hz100\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}100pG∕Hz​ (rms) in a $3.5\text{\ensuremath{-}}\mathrm{cm}$-diameter paraffin coated cell. Assuming detection at the photon shot-noise limit, we project a sensitivity as low as 25pG∕Hz25\phantom{\rule{0.3em}{0ex}}\mathrm{pG}∕\sqrt{\mathrm{Hz}}25pG∕Hz​ (rms).