Enhancing Long-Term Stability of Atomic Spin Polarization Based on Data-Fusion in Quantum Sensing

zehua liu, Yifan Yan, Zhuo Wang, Haoying Pang, Feng Li, Jiahang Li, Bodong Qin

Published Jan 1, 2024• 0 citations
Publisher
DOI
10.2139/ssrn.4861076

Related papers

Enhancing long-term stability of atomic spin polarization based on data-fusion in SERF co-magnetometer

Zehua Liu, Yifan Yan, Zhuo Wang +3 more

Measurement•Jun 19, 2025•5 citations

Quantum control and measurement of atomic spins in polarization spectroscopy

Ivan Deutsch, Poul Jessen

arXiv:0909.4506•Optics Communications•Nov 7, 2009•119 citations

A novel approach for enhancement of atomic spin polarization in spin-exchange relaxation-free gyroscopes based on a homogenized light field

Longyan Ma, Xiaohan Ge, Haoying Pang +7 more

Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.

Measurement Science and Technology•Nov 25, 2025•3 citations

Analysis and suppression of spin polarization error in atomic spin gyroscope based on adaptive light compensation

Zehua Liu, Yifan Yan, Zhuo Wang +5 more

• A dual-spectrum feedback architecture based on conventional closed-loop control is proposed, enabling real-time compensation for spin polarization error (SPE) in the K-Rb-21Ne atomic spin gyroscope, significantly enhancing long-term stability. • An adaptive dynamic control strategy based on a Lyapunov function is introduced to replace PID control, optimizing control parameters and improving system response speed and stability. • Experimental results show that the method improves SPE suppression by 54.4%, 74.5%, and 74.6% for clustering times of 100s, 500s, and 1000s, respectively. • Interference tests demonstrate that the method effectively eliminates steady-state offsets and enhances the system's adaptability to power density and polarization fluctuations, providing a long-term stability solution for optically pumped atomic devices. The long-term stability of atomic spin polarization plays a critical role in ensuring the sustained stability of atomic gyroscope outputs. However, drift in the laser pumping rate introduces the spin polarization error (SPE), necessitating high-precision closed-loop stabilization. Conventional single-beam-splitting closed-loop control methods overlook the time-varying characteristics of beam-splitting elements during prolonged operation, resulting in incomplete suppression of SPE in long-term measurements. To address this limitation, a dynamic light compensation framework is developed for the analysis and suppression of SPE in an atomic spin gyroscope. The proposed structure enables real-time monitoring of parameter variations in the beam-splitting elements and feeds this information back into the control loop to actively compensate for polarization errors induced by optical drift. Furthermore, an adaptive control method based on nonlinear inversion and disturbance observation is introduced, which estimates the internal state and compensates time-varying parameters in real time, thereby replacing conventional PID control and ensuring optimal closed-loop performance. Experimental results from a K-Rb- 21 Ne atomic gyroscope demonstrate real-time suppression of SPE, with improvements of 54.4%, 74.5%, and 74.6% for clustering times of 100, 500, and 1000 seconds, respectively. Interference tests show enhanced response speed and the elimination of steady-state offsets under power density and polarization disturbances. This method offers a novel solution for achieving long-term stability in optically pumped atomic devices, ensuring sustained measurement accuracy.

Results in Engineering•Dec 25, 2025•0 citations

Hybrid sensing approaches for quantum spin sensors

Michael E. Flatté

Bulletin of the American Physical Society•Mar 4, 2020•0 citations

Systematic errors from inhomogeneous alkali-spin polarization in NMR gyroscopes and comagnetometers

Xiangdong Zhang, Jinbo Hu, Juhao Luo +2 more

Abstract Isotope shift, a systematic error arising from the alkali polarization field generated by the spin-exchange collisions between the Xe and Alkali atoms, has been observed in many $\rm ^{129}Xe$-$\rm ^{131}Xe$ comagnetometer studies. This isotope shift constitutes a major source of systematic errors that ultimately limiting the measurement precision and long-term stability of comagnetometers. In this work, we present a comprehensive analysis of how a spatially inhomogeneous alkali polarization field induces the isotope shift through the diffusion motion of Xe atoms. We identify two primary physical mechanisms responsible for the isotope shift: the mismatch of the wall relaxation rates and the large difference of the gyromagnetic ratios between $\rm ^{129}Xe$ and $\rm ^{131}Xe$ spins. Focusing on the alkali polarization field produced by a Gaussian pump beam, we perform detailed analytical and numerical evaluations on the magnitude and stability of isotope shift. These results offer practical guidance for optimizing the experimental working point, thereby enhancing the absolute accuracy and long-term stability of $\rm ^{129}Xe$-$\rm ^{131}Xe$ comagnetometers and nuclear magnetic resonance (NMR) gyroscopes.

Physical Review A•May 12, 2026•1 citation
Abstract Atomic spin comagnetometers based on the spin-exchange relaxation-free (SERF) effect offer significant potential for inertial sensing and support the development of long-endurance, high-precision navigation technologies. However, limited nuclear spin polarization constrains the long-term stability of these systems. Here, a flat-top optical pumping configuration is introduced for SERF comagnetometers, expanding the uniform-intensity region of the beam to approximately 62 % , which enhances atomic polarization by around 19 % and improves magnetic noise suppression by 32 % . Experimental results demonstrate notable improvements in both sensitivity and long-term stability, highlighting the effectiveness of flat-top beams in overcoming atomic polarization uniformity limitations and advancing SERF co-magnetometer performance.
• A dual-spectrum feedback architecture based on conventional closed-loop control is proposed, enabling real-time compensation for spin polarization error (SPE) in the K-Rb-21Ne atomic spin gyroscope, significantly enhancing long-term stability. • An adaptive dynamic control strategy based on a Lyapunov function is introduced to replace PID control, optimizing control parameters and improving system response speed and stability. • Experimental results show that the method improves SPE suppression by 54.4%, 74.5%, and 74.6% for clustering times of 100s, 500s, and 1000s, respectively. • Interference tests demonstrate that the method effectively eliminates steady-state offsets and enhances the system's adaptability to power density and polarization fluctuations, providing a long-term stability solution for optically pumped atomic devices. The long-term stability of atomic spin polarization plays a critical role in ensuring the sustained stability of atomic gyroscope outputs. However, drift in the laser pumping rate introduces the spin polarization error (SPE), necessitating high-precision closed-loop stabilization. Conventional single-beam-splitting closed-loop control methods overlook the time-varying characteristics of beam-splitting elements during prolonged operation, resulting in incomplete suppression of SPE in long-term measurements. To address this limitation, a dynamic light compensation framework is developed for the analysis and suppression of SPE in an atomic spin gyroscope. The proposed structure enables real-time monitoring of parameter variations in the beam-splitting elements and feeds this information back into the control loop to actively compensate for polarization errors induced by optical drift. Furthermore, an adaptive control method based on nonlinear inversion and disturbance observation is introduced, which estimates the internal state and compensates time-varying parameters in real time, thereby replacing conventional PID control and ensuring optimal closed-loop performance. Experimental results from a K-Rb- 21 Ne atomic gyroscope demonstrate real-time suppression of SPE, with improvements of 54.4%, 74.5%, and 74.6% for clustering times of 100, 500, and 1000 seconds, respectively. Interference tests show enhanced response speed and the elimination of steady-state offsets under power density and polarization disturbances. This method offers a novel solution for achieving long-term stability in optically pumped atomic devices, ensuring sustained measurement accuracy.
Abstract Isotope shift, a systematic error arising from the alkali polarization field generated by the spin-exchange collisions between the Xe and Alkali atoms, has been observed in many 129Xe\rm ^{129}Xe129Xe-131Xe\rm ^{131}Xe131Xe comagnetometer studies. This isotope shift constitutes a major source of systematic errors that ultimately limiting the measurement precision and long-term stability of comagnetometers. In this work, we present a comprehensive analysis of how a spatially inhomogeneous alkali polarization field induces the isotope shift through the diffusion motion of Xe atoms. We identify two primary physical mechanisms responsible for the isotope shift: the mismatch of the wall relaxation rates and the large difference of the gyromagnetic ratios between 129Xe\rm ^{129}Xe129Xe and 131Xe\rm ^{131}Xe131Xe spins. Focusing on the alkali polarization field produced by a Gaussian pump beam, we perform detailed analytical and numerical evaluations on the magnitude and stability of isotope shift. These results offer practical guidance for optimizing the experimental working point, thereby enhancing the absolute accuracy and long-term stability of 129Xe\rm ^{129}Xe129Xe-131Xe\rm ^{131}Xe131Xe comagnetometers and nuclear magnetic resonance (NMR) gyroscopes.