Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

中国科学通报:英文版

Direct demonstration of spin-squeezing-induced metrological enhancement on state-of-the-art optical atomic clocks

Jingbiao Chen, Deshui Yu

Published Apr 1, 2024• 6 citations
Publisher
DOI
10.1016/j.scib.2024.04.001

Related papers

Spin-squeezing-enhanced optical lattice clocks with 10 − 19 -level differential frequency stability at the averaging time of 1 s

Deshui Yu, Jia Zhang, Tongyan Xia +3 more

Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.

Physical Review A•Jul 1, 2024•4 citations

Progress toward a spin squeezed optical atomic clock beyond the standard quantum limit

Boris Braverman, Akio Kawasaki, Vladan Vuletić

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

Differential Frequency Comparison of Conditionally and Unconditionally Spin‐Squeezed States of an Optical Lattice Clock

Deshui Yu, Xiaobo Xue, Jia Zhang +2 more

Abstract Optical lattice clocks are the world's most accurate and stable timepieces. Thus far, the differential clock comparison has reached a stability limited by the quantum projection noise of uncorrelated atoms. Overcoming this limit relies on using spin squeezing, where quantum fluctuations of the collective spin undergo a strong suppression in one direction while being enhanced in the conjugation direction. The recent differential comparison of spin‐squeezed clocks mainly employs multiple atomic clouds or sub‐ensembles within one cloud, complicating the clock operation. Here, it is numerically investigated the differential comparison of conditionally and unconditionally spin‐squeezed states of one lattice‐trapped cloud of neutral atoms. The simulation results in a comparison stability of at the averaging time for atoms. The metrological gain reaches dB, primarily limited by the decoherence induced by quantum jumps of intracavity probe photons during quantum non‐demolition measurements. Besides the quantum precision enhancement, our scheme paves the way to using one spin squeezing protocol to appraise the other.

Advanced Quantum Technologies•Feb 13, 2025•0 citations

Toward Unitary Spin Squeezing for Atomic Clocks

Boris Braverman, Akio Kawasaki, Edwin Pedrozo-Peñafiel +4 more

Bulletin of the American Physical Society•Jun 1, 2018•0 citations

Optical atomic clocks and metrology

Andrew D. Ludlow

Bulletin of the American Physical Society•Jun 6, 2014•0 citations

Clock Precision beyond the Standard Quantum Limit at 10 − 18 Level

Yutong Yang, Maya Miklos, Yee Ming Tso +3 more

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

arXiv:2505.04538•Physical Review Letters•Nov 7, 2025•21 citations
Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.
Abstract Optical lattice clocks are the world's most accurate and stable timepieces. Thus far, the differential clock comparison has reached a stability limited by the quantum projection noise of uncorrelated atoms. Overcoming this limit relies on using spin squeezing, where quantum fluctuations of the collective spin undergo a strong suppression in one direction while being enhanced in the conjugation direction. The recent differential comparison of spin‐squeezed clocks mainly employs multiple atomic clouds or sub‐ensembles within one cloud, complicating the clock operation. Here, it is numerically investigated the differential comparison of conditionally and unconditionally spin‐squeezed states of one lattice‐trapped cloud of neutral atoms. The simulation results in a comparison stability of at the averaging time for atoms. The metrological gain reaches dB, primarily limited by the decoherence induced by quantum jumps of intracavity probe photons during quantum non‐demolition measurements. Besides the quantum precision enhancement, our scheme paves the way to using one spin squeezing protocol to appraise the other.
Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.