Quantum metrology technology is an advanced measurement method, which can achieve the accuracy that classical metrology is difficult to measure, and supplement the accuracy and stability defects caused by the standard quantum limit. In addition, reproducing quantum effects and quantum phenomena into units of metrology, which is obviously superior to the traditional measurement technology in terms of measurement accuracy, sensitivity and stability that could realize the quantum value transfer and traceability activities. With the development of laser cooling and trapping atom technology, the pressure measurement range of cold atom quantum-based vacuum metrology(CAVM) may reach 10-4~10-10 Pa or even lower . Benefiting from the loss rate of cold atoms in CAVM is only controlled by the collision cross section between cold atoms and gases, CAVM has the potential to develop into a emerging generation of vacuum metrology technology27. In this paper, the basic concept, structure and working principle of magneto-optical traps(MOT) for laser cooling atoms and trapping atoms are briefly described; Then, the basic principle of the CAVM is introduced. Furthermore, through collecting and sorting out a large number of literature about this technology, the advantages and key technologies of this technique in recent years are comprehensively analyzed and summarized; Finally, the developing trend of the CAVM is prospected.
Quantum metrology technology is an advanced measurement method, which can achieve the accuracy that classical metrology is difficult to measure, and supplement the accuracy and stability defects caused by the standard quantum limit. In addition, reproducing quantum effects and quantum phenomena into units of metrology, which is obviously superior to the traditional measurement technology in terms of measurement accuracy, sensitivity and stability that could realize the quantum value transfer and traceability activities. With the development of laser cooling and trapping atom technology, the pressure measurement range of cold atom quantum-based vacuum metrology(CAVM) may reach 10-4~10-10 Pa or even lower . Benefiting from the loss rate of cold atoms in CAVM is only controlled by the collision cross section between cold atoms and gases, CAVM has the potential to develop into a emerging generation of vacuum metrology technology27. In this paper, the basic concept, structure and working principle of magneto-optical traps(MOT) for laser cooling atoms and trapping atoms are briefly described; Then, the basic principle of the CAVM is introduced. Furthermore, through collecting and sorting out a large number of literature about this technology, the advantages and key technologies of this technique in recent years are comprehensively analyzed and summarized; Finally, the developing trend of the CAVM is prospected.
Ultra-high vacuum measurement and extremely high vacuum (UHV/XHV) measurement play an important role in high-tech fields such as deep space exploration, particle accelerators, and nanoscience; with the continuous extension of the lower limit of measurement, especially when it reaches the order of 10–10 Pa, higher requirements are placed on the accuracy of the measurement. At present, in the field of UHV/XHV measurement, ionization gauges based on the principle of neutral gas ionization are commonly applied to the vacuum measurement. However, traditional ionization vacuum gauges during use can create electronic excitation desorption effects, soft X-rays, and the effect of hot cathode outgassing, thereby affecting the accuracy of measurement and limiting the lower limit of measurement. Compared with the traditional measurement technology, this method uses the relationship between the loss rate and pressure caused by the collision of cold atoms trapped in the trap depth with the background gas to calculate the gas density and inversely calculate the vacuum pressure. Based on the intrinsic quantum mechanical properties of cold atom collisions, this method is expected to be developed into a new vacuum traceability standard. In this paper, based on the small-angle approximation and impulse approximation under the quantum scattering theory, the loss rate coefficient of the collision of 6Li cold atoms with background gas molecules is calculated. According to the ideal gas equation, the pressure inversion formula is obtained. The collision loss rate is extracted by accurately fitting the loss curve of the cold atom. In order to improve the accuracy of vacuum inversion and reduce the influence of quantum diffractive collision on loss rate measurement, the trap depth under the conditions of a certain cooling laser intensity, detuning, and magnetic field gradient is determined by the photoassociation method. Finally, in a range of 1 × 10–8–5 × 10–6 Pa, the inverted pressure value is compared with the measured value of the ionization meter, proving that this method has good accuracy and reliability in the inversion of vacuum pressure. At present, the main factor restricting the improvement of accuracy is the influence of the collision between the excited atoms in the magneto-optical trap and the background gas on the loss rate measurement. In the future, with the proportion of excited atoms and the excited state C6 coefficient to be precisely determined, the uncertainty of vacuum pressure measurement can be further reduced.
The cold atomic gravimeter (CAG) has the advantage of high measurement accuracy and does not need to be calibrated on a regular basis. To achieve cold atom interference, it is first necessary to cool and trap the atoms by magneto-optical trap (MOT). However, there are many types of MOTs, and their trapping and cooling results directly affect the atomic interference, and thus, the measurement accuracy of a CAG. MOTs should be designed or selected correctly for different application needs. This paper reviews the research history of MOTs and analyzes their structure and principles. The current status of applications of different types of MOTs is highlighted. Their advantages and disadvantages are summarized, and perspectives for the development of MOTs for cold atomic gravimetry are presented.
We describe how laser-cooled and trapped alkali-metal atoms have been used as pressure sensors in the high- and ultra-high-vacuum regimes operating with relative uncertainties of just over a percent at pressures from a few nPa and up to a few tens of μPa. These sensors can serve as primary standards of pressure as the determination of pressure requires only knowledge of collision cross sections between atoms and molecules, eliminating the need for calibration with other devices. The collision cross sections can be measured independently or computed with rigorous quantum methods at percent relative accuracies. We argue that this technology has advanced sufficiently to provide an alternative to the existing, expensive pressure standard in the ultra-high vacuum regime, the orifice flow standard. Experiments with trapped atoms can be used to calibrate cheaper pressure sensors (such as devices based on ionization gauges). However, the technology has not yet matured enough to be of use in other research fields because of the complexity and cost of the experiments. We propose a roadmap for this new pressure standard for vacuum metrology.
Cold atoms play a very important role in metrology. The ultra-high or extreme-high vacuum pressure can be accurately measured by investigating the collision of cold atoms and residual atoms in the environment. We report a vacuum pressure metrometer using cold 7Li atoms as sensor atoms in a magneto-optical trap and a magnetic trap. The accuracy, uncertainty, and feasibility of the measurements in such two different traps are studied and compared in the pressure range from 10−5 to 10−8 Pa. It is found that the vacuum pressure measurement in a magneto-optical trap is more advantageous with a higher accuracy, higher signal-to-noise ratio, and shorter measurement time under current conditions. The results may be used to realize an applicable cold atom quantum vacuum standard.
The redefinition of the International System of Units (SI) promotes the transformation of the vacuum measurement system toward quantization, and the quantization of vacuum parameters is one of the most leading, prospective and subversive research directions in the field of international vacuum metrology, and the quantum vacuum measurement is based on the quantum effect of the microscopic particle system, and the use of optical means and the theory of quantum mechanics to realize the precision measurement of the vacuum parameters. We develop a lithium-cooled atom vacuum measurement apparatus, which mainly consists of a 7Li atom trap system and a continuous expansion vacuum system. In this work, an experimental study of ultrahigh vacuum measurement is carried out by manipulating 7Li atoms and utilizing the loss characteristics of lithium cold atoms in magneto-optical and magnetic traps, and the results show that for the four commonly used gas molecules in vacuum, namely N2, Ar, He, and H2, in the vacuum range of (3×10–8–4×10–5) Pa, the maximum measurement uncertainty is 7.6%–6.0% (k = 2) based on 7Li cold atoms, and the cold atom vacuum measurement results are in good agreement with those of the traditional ionization vacuum gauges, and their relative sensitivities are in good agreement with those of the ionization vacuum gauges, and the maximal deviation of the relative sensitivity factor is less than 8%, which verifies the accuracy and reliability of the cold-atom quantum vacuum measurements. The research results are of great significance in promoting the development of new cross-generation vacuum measurement technology and meeting the needs of space science exploration, ultra-precision measurement and high-end equipment manufacturing.
Abstract Laser-cooled atoms are a key technology for many calibration-free measurement platforms—including clocks, gyroscopes, and gravimeters—and are a promising system for quantum networking and quantum computing. The optics and vacuum hardware required to prepare these gases are often bulky and not amenable to large-volume manufacturing, limiting the practical realization of devices benefiting from the properties of cold atoms. Planar, lithographically produced optics including photonic integrated circuits, optical metasurfaces (MSs), and gratings offer a pathway to develop chip-scale, manufacturable devices utilizing cold atoms. As a demonstration of this technology, we have realized laser cooling of atomic Rb in a grating-type magneto-optical trap (MOT) using planar optics for beam launching, beam shaping, and polarization control. Efficient use of available light is accomplished using MS-enabled beam shaping, and the performance of the planar optics MOT is competitive with Gaussian-beam illuminated grating MOTs.