Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Effects and Measurement Techniques in Biology and Biophotonics

Quantum enhancement in the limit of detection measurement of a phase-based plasmonic biosensor including loss

Kelvin Tafadzwa Mpofu, Patience T. Mthunzi-Kufa

Published Mar 13, 2024• 4 citations
Publisher

Abstract

Quantum states of light allow for highly sensitive biosensing configurations, surpassing the limitations imposed by shot-noise. In this theoretical study, we focus on optical plasmonic sensors, which have extensive applications in disease diagnostics, including detection of diseases like HIV. Our investigation involves simulating the impact of quantum states of light, such as the NOON state and squeezed states, on enhancing the limit of detection in a plasmonic phase-sensing biosensor, surpassing coherent light states’ shot-noise limit. Specifically, we explore the use of quantum states to improve the limit of detection in phase-based biosensors for HIV detection, operating below the shot-noise limit. Through our analysis, we demonstrate that incorporating quantum states of light in surface plasmon resonance (SPR) biosensing leads to enhanced performance compared to classical states. Moreover, we take into account the impact of environmental losses in the biosensing setup, considering the real-world challenges in practical implementation. Our findings emphasize the potential of quantum SPR biosensors in the development of novel disease diagnostics devices.

DOI
10.1117/12.3002465

Related papers

Enhanced phase-based plasmonic biosensing with quantum states of light

Kelvin Tafadzwa Mpofu, Patience T. Mthunzi-Kufa

Abstract Our research aims to create a theoretical framework that may be used to improve phase-based surface plasmon resonance (SPR) biosensor precision beyond the shot noise limit by utilizing quantum states including squeezed states and NOON states. For this work, a two-mode phase sensing setup model is created. One of the two arms of the two mode model of this model has an integrated SPR system based on the Krestchmann arrangement. An experiment involving phase-based plasmonic biosensing is modeled using the two-mode setup. The state preparation, the biosensing component, and the measurement comprise the three main components of the model. The measurement varies depending on the particular input state. Quantum noise reduction for quantum states results from the combination of the sub-Poissonian statistical structure of a single mode and the non-classical correlation of the photon number between the two modes (entanglement). We show that when combined with the high sensitivity of the SPR sensor, the use of two-mode quantum states of light considerably increases the estimation precision of the refractive index of an analyte. Here, we use distilled water diluted BSA solutions at different concentrations that correlate to different refractive indices to reproduce a static phase-based SPR biosensor. Both lossless and lossy circumstances were taken into consideration for the model. The NOON state and the product coherent squeezed vacuum (PCSV) state are the two main quantum states taken into consideration in this work. The PCSV state exhibited the better limit of detection (LOD) among the states that we measured, suggesting that it is a promising candidate for the development of quantum biosensing systems. The effect of losses will require more investigation, but this work enables us to identify a precise course of action for enhancing the performance of the phase-based surface plasmon resonance sensor even further. Phase-based quantum SPR sensors have yet to be thoroughly examined, but intensity-based quantum SPR sensors have previously been extensively researched in the biochemical and medical sensing domains.

Journal of Physics Conference Series•Mar 1, 2025•0 citations

Comparing amplitude-based and phase-based quantum plasmonic biosensing

Kelvin Tafadzwa Mpofu, Patience T. Mthunzi-Kufa

The utilization of quantum resources can enhance the sensitivity of conventional measurement techniques beyond the standard quantum limit (SQL). The objective of quantum metrology is to enable such quantum enhancements in practical devices. To achieve this objective, it is essential to have devices that are compatible with existing quantum resources operating within the SQL. Plasmonic sensors are promising candidates among these devices since they are extensively employed in biochemical sensing applications. Plasmonic sensors exhibit a response to slight variations in the local refractive index, which manifests as a shift in their resonance response. This shift, in turn, induces changes in the amplitude and phase of the probing light. By utilizing quantum states of light, such as NOON states, squeezed states, or Fock states, to probe these sensors, the measurement noise floor can be lowered, enabling the detection of signals below the SQL. In this study, we compare two configurations of quantum plasmonic sensing: phase-based and amplitude-based. By considering the Quantum Cramér Rao bound for both configurations, we demonstrate that the phase-based configuration can more effectively exploit the available quantum resources than the amplitude-based configuration. A limitation of this work is that it did not consider loss.

Quantum Effects and Measurement Techniques in Biology and Biophotonics•Jan 29, 2024•4 citations

Plasmonics and sensing beyond classical limits

Mark Tame, Changhyoup Lee

Optical sensors have applications in a range of settings, from measuring mechanical vibrations in manufacturing processes to biometrics in security devices and the detection of proteins and viruses in biomedical research. Many sensing approaches exist and plasmonic systems in particular have been studied extensively due to their ability to confine light below the diffraction limit, which greatly enhances their sensitivity compared to conventional approaches. Recently, various quantum techniques have been discovered that can outperform classical sensing ones and provide sensitivity beyond the shot-noise limit. The use of these quantum techniques in plasmonics for improving sensing performance is currently being explored. We study the performance of a plasmonic sensor that exploits the quantum nature of light and its highly confined field. We consider specialized quantum states and by comparison we show how each can provide improved sensitivity beyond the shot-noise limit.

Quantum Nanophotonic Materials, Devices, and Systems•Sep 3, 2019•10 citations

Quantum plasmonic sensing with application to HIV research.

Kelvin Tafadzwa Mpofu

The main goal of this thesis is to show how the use of quantum states of light in biosensing \nwith surface plasmon resonance (SPR) gives an enhancement over using classical \nstates. SPR is a highly sensitive technique for monitoring changes in the optical properties \nof a substance in the immediate vicinity of a sensor surface, which makes it very \nuseful in biosensing and surface science research. We focus primarily on a bio-sensing \nSPR setup known as the Kretschmann con guration in which surface plasmons are excited \nusing a bulk prism and a gold coated microscope slide. The excitation is performed \nby means of an evanescent eld arising from total internal re \nection from the backside \nof the sensor surface. \nWe show theoretically that using quantum states of light such as the Fock state, twomode \nsqueezed vacuum and two-mode squeezed displaced state improves the precision \nin the estimation of kinetic parameters measured from the sensorgrams produced by the \nKretschmann con guration. Quantum states of light allow us to measure the parameters \nmore accurately in comparison to the use of classical states of light. We look at a theoretical \napplication of quantum bio-sensing in an immobilized Bovine serum albumin (BSA) \ninteraction with anti-BSA, a binding reaction between a phosphate-bu ered saline (PBS) \nsolution that contains Bovine carbonic anhydrase and its inhibitor benzene-sulfonamide, \nand a HIV case study. In our HIV case study we look at the binding reaction between a \nvariant of HIV-1 protease and nel navir which is an inhibitor. \nThe thesis also looks at an experimental implementation of the Kretschmann con guration \nwith light from a single-photon source and shows an enhancement in sensitivity. We \nuse the spontaneous parametric down conversion process to generate our single photons \nwhich we use to study the binding kinetics of BSA on a gold slide. This experiment is \ndone with the anticipation that it will be extended in future to a drug kinetics study \nwith HIV protease as we look at drug development.

•Jan 1, 2020•3 citations

Quantum Plasmonic Sensing: Beyond the Shot-Noise and Diffraction Limit

Changhyoup Lee, Frederik Dieleman, Jinhyoung Lee +3 more

Photonic sensors have many applications in a range of physical settings, from measuring mechanical pressure in manufacturing to detecting protein concentration in biomedical samples. A variety of sensing approaches exist, and plasmonic systems in particular have received much attention due to their ability to confine light below the diffraction limit, greatly enhancing sensitivity. Recently, quantum techniques have been identified that can outperform classical sensing methods and achieve sensitivity below the so-called shot-noise limit. Despite this significant potential, the use of definite photon number states in lossy plasmonic systems for further improving sensing capabilities is not well studied. Here, we investigate the sensing performance of a plasmonic interferometer that simultaneously exploits the quantum nature of light and its electromagnetic field confinement. We show that, despite the presence of loss, specialized quantum resources can provide improved sensitivity and resolution beyond the shot-noise limit within a compact plasmonic device operating below the diffraction limit.

arXiv:1601.00173•ACS Photonics•May 16, 2016•73 citations

Quantum plasmonic sensing

Wenjiang Fan, Benjamin J. Lawrie, Raphael C. Pooser

Surface plasmon resonance (SPR) sensors can reach the quantum noise limit of the optical readout field in various configurations. We demonstrate that two-mode intensity squeezed states produce a further enhancement in sensitivity compared with a classical optical readout when the quantum noise is used to transduce an SPR sensor signal in the Kretschmann configuration. The quantum noise reduction between the twin beams when incident at an angle away from the plasmonic resonance, combined with quantum noise resulting from quantum anticorrelations when on resonance, results in an effective SPR-mediated modulation that yields a measured sensitivity 5 dB better than that with a classical optical readout in this configuration. The theoretical potential of this technique points to resolving particle concentrations with more accuracy than is possible via classical approaches to optical transduction.

Physical Review A•Nov 4, 2015•95 citations
Quantum states of light allow for highly sensitive biosensing configurations, surpassing the limitations imposed by shot-noise. In this theoretical study, we focus on optical plasmonic sensors, which have extensive applications in disease diagnostics, including detection of diseases like HIV. Our investigation involves simulating the impact of quantum states of light, such as the NOON state and squeezed states, on enhancing the limit of detection in a plasmonic phase-sensing biosensor, surpassing coherent light states’ shot-noise limit. Specifically, we explore the use of quantum states to improve the limit of detection in phase-based biosensors for HIV detection, operating below the shot-noise limit. Through our analysis, we demonstrate that incorporating quantum states of light in surface plasmon resonance (SPR) biosensing leads to enhanced performance compared to classical states. Moreover, we take into account the impact of environmental losses in the biosensing setup, considering the real-world challenges in practical implementation. Our findings emphasize the potential of quantum SPR biosensors in the development of novel disease diagnostics devices.
Abstract Our research aims to create a theoretical framework that may be used to improve phase-based surface plasmon resonance (SPR) biosensor precision beyond the shot noise limit by utilizing quantum states including squeezed states and NOON states. For this work, a two-mode phase sensing setup model is created. One of the two arms of the two mode model of this model has an integrated SPR system based on the Krestchmann arrangement. An experiment involving phase-based plasmonic biosensing is modeled using the two-mode setup. The state preparation, the biosensing component, and the measurement comprise the three main components of the model. The measurement varies depending on the particular input state. Quantum noise reduction for quantum states results from the combination of the sub-Poissonian statistical structure of a single mode and the non-classical correlation of the photon number between the two modes (entanglement). We show that when combined with the high sensitivity of the SPR sensor, the use of two-mode quantum states of light considerably increases the estimation precision of the refractive index of an analyte. Here, we use distilled water diluted BSA solutions at different concentrations that correlate to different refractive indices to reproduce a static phase-based SPR biosensor. Both lossless and lossy circumstances were taken into consideration for the model. The NOON state and the product coherent squeezed vacuum (PCSV) state are the two main quantum states taken into consideration in this work. The PCSV state exhibited the better limit of detection (LOD) among the states that we measured, suggesting that it is a promising candidate for the development of quantum biosensing systems. The effect of losses will require more investigation, but this work enables us to identify a precise course of action for enhancing the performance of the phase-based surface plasmon resonance sensor even further. Phase-based quantum SPR sensors have yet to be thoroughly examined, but intensity-based quantum SPR sensors have previously been extensively researched in the biochemical and medical sensing domains.
The utilization of quantum resources can enhance the sensitivity of conventional measurement techniques beyond the standard quantum limit (SQL). The objective of quantum metrology is to enable such quantum enhancements in practical devices. To achieve this objective, it is essential to have devices that are compatible with existing quantum resources operating within the SQL. Plasmonic sensors are promising candidates among these devices since they are extensively employed in biochemical sensing applications. Plasmonic sensors exhibit a response to slight variations in the local refractive index, which manifests as a shift in their resonance response. This shift, in turn, induces changes in the amplitude and phase of the probing light. By utilizing quantum states of light, such as NOON states, squeezed states, or Fock states, to probe these sensors, the measurement noise floor can be lowered, enabling the detection of signals below the SQL. In this study, we compare two configurations of quantum plasmonic sensing: phase-based and amplitude-based. By considering the Quantum Cramér Rao bound for both configurations, we demonstrate that the phase-based configuration can more effectively exploit the available quantum resources than the amplitude-based configuration. A limitation of this work is that it did not consider loss.
Optical sensors have applications in a range of settings, from measuring mechanical vibrations in manufacturing processes to biometrics in security devices and the detection of proteins and viruses in biomedical research. Many sensing approaches exist and plasmonic systems in particular have been studied extensively due to their ability to confine light below the diffraction limit, which greatly enhances their sensitivity compared to conventional approaches. Recently, various quantum techniques have been discovered that can outperform classical sensing ones and provide sensitivity beyond the shot-noise limit. The use of these quantum techniques in plasmonics for improving sensing performance is currently being explored. We study the performance of a plasmonic sensor that exploits the quantum nature of light and its highly confined field. We consider specialized quantum states and by comparison we show how each can provide improved sensitivity beyond the shot-noise limit.
The main goal of this thesis is to show how the use of quantum states of light in biosensing \nwith surface plasmon resonance (SPR) gives an enhancement over using classical \nstates. SPR is a highly sensitive technique for monitoring changes in the optical properties \nof a substance in the immediate vicinity of a sensor surface, which makes it very \nuseful in biosensing and surface science research. We focus primarily on a bio-sensing \nSPR setup known as the Kretschmann con guration in which surface plasmons are excited \nusing a bulk prism and a gold coated microscope slide. The excitation is performed \nby means of an evanescent eld arising from total internal re \nection from the backside \nof the sensor surface. \nWe show theoretically that using quantum states of light such as the Fock state, twomode \nsqueezed vacuum and two-mode squeezed displaced state improves the precision \nin the estimation of kinetic parameters measured from the sensorgrams produced by the \nKretschmann con guration. Quantum states of light allow us to measure the parameters \nmore accurately in comparison to the use of classical states of light. We look at a theoretical \napplication of quantum bio-sensing in an immobilized Bovine serum albumin (BSA) \ninteraction with anti-BSA, a binding reaction between a phosphate-bu ered saline (PBS) \nsolution that contains Bovine carbonic anhydrase and its inhibitor benzene-sulfonamide, \nand a HIV case study. In our HIV case study we look at the binding reaction between a \nvariant of HIV-1 protease and nel navir which is an inhibitor. \nThe thesis also looks at an experimental implementation of the Kretschmann con guration \nwith light from a single-photon source and shows an enhancement in sensitivity. We \nuse the spontaneous parametric down conversion process to generate our single photons \nwhich we use to study the binding kinetics of BSA on a gold slide. This experiment is \ndone with the anticipation that it will be extended in future to a drug kinetics study \nwith HIV protease as we look at drug development.
Photonic sensors have many applications in a range of physical settings, from measuring mechanical pressure in manufacturing to detecting protein concentration in biomedical samples. A variety of sensing approaches exist, and plasmonic systems in particular have received much attention due to their ability to confine light below the diffraction limit, greatly enhancing sensitivity. Recently, quantum techniques have been identified that can outperform classical sensing methods and achieve sensitivity below the so-called shot-noise limit. Despite this significant potential, the use of definite photon number states in lossy plasmonic systems for further improving sensing capabilities is not well studied. Here, we investigate the sensing performance of a plasmonic interferometer that simultaneously exploits the quantum nature of light and its electromagnetic field confinement. We show that, despite the presence of loss, specialized quantum resources can provide improved sensitivity and resolution beyond the shot-noise limit within a compact plasmonic device operating below the diffraction limit.
Surface plasmon resonance (SPR) sensors can reach the quantum noise limit of the optical readout field in various configurations. We demonstrate that two-mode intensity squeezed states produce a further enhancement in sensitivity compared with a classical optical readout when the quantum noise is used to transduce an SPR sensor signal in the Kretschmann configuration. The quantum noise reduction between the twin beams when incident at an angle away from the plasmonic resonance, combined with quantum noise resulting from quantum anticorrelations when on resonance, results in an effective SPR-mediated modulation that yields a measured sensitivity 5 dB better than that with a classical optical readout in this configuration. The theoretical potential of this technique points to resolving particle concentrations with more accuracy than is possible via classical approaches to optical transduction.