Vacuum

Cold atom technology applied to ultra-high vacuum (UHV) measurements

Wenjun Sun, Xiangmin Wu, Yongjun Cheng, Meng Dong, Z.J. Ma, Wenjie Jia, Yafei Zhang, Ruifang Zhang, Chengyao Wu, Cun Feng, Hong‐Gang Luo

Published Feb 23, 2024• 6 citations
Publisher
DOI
10.1016/j.vacuum.2024.113079

Related papers

Advances in cold atom UHV/XHV metrology

Xiangmin Wu, Yongjun Cheng, Dong Meng +7 more

Vacuum•Oct 6, 2022•6 citations

Development of an ultra-high vacuum system for space cold atom clock

Wei Ren, Jingfeng Xiang, Yuantao Zhang +6 more

Vacuum•Mar 11, 2015•13 citations

Development of an ultra-high vacuum system for a cold atom physics rack in space

Qian Liu, Y. Xie, Lin Li +7 more

Vacuum•Mar 13, 2021•13 citations

Non-Reactive Atom-Molecule Scattering in Support of a Cold-Atom Based UHV Pressure Sensor

Constantinos Makrides, Eite Tiesinga

Bulletin of the American Physical Society•May 29, 2018•0 citations

Integrated atomic quantum technologies in demanding environments: development and qualification of miniaturized optical setups and integration technologies for UHV and space operation

Marc Christ, Alexander Kassner, Robert Smol +6 more

Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.

International Conference on Space Optics (ICSO)•Jul 12, 2019•1 citation

Challenges to miniaturizing cold atom technology for deployable vacuum metrology

Stephen Eckel, Daniel S. Barker, James A. Fedchak +5 more

Cold atoms are excellent metrological tools; they currently realize SI time and, soon, SI pressure in the ultra-high (UHV) and extreme high vacuum (XHV) regimes. The development of primary, vacuum metrology based on cold atoms currently falls under the purview of national metrology institutes. Under the emerging paradigm of the "quantum-SI", these technologies become deployable (relatively easy-to-use sensors that integrate with other vacuum chambers), providing a primary realization of the pascal in the UHV and XHV for the end-user. Here, we discuss the challenges that this goal presents. We investigate, for two different modes of operation, the expected corrections to the ideal cold-atom vacuum gauge and estimate the associated uncertainties. Finally, we discuss the appropriate choice of sensor atom, the light Li atom rather than the heavier Rb.

arXiv:1809.05378•Metrologia•Aug 21, 2018•53 citations
Employing compact quantum sensors in field or in space (e.g., small satellites) implies demanding requirements on components and integration technologies. Within our work on integrated sensors, we develop miniaturized, ultra-stable optical setups for optical cooling and trapping of cold atomic gases. Besides challenging demands on alignment precision, and thermo-mechanical durability, we specifically address ultra-high vacuum (UHV) compatibility of our integration technologies and optical components. A prototype design of an UHV-compatible, crossed beam optical dipole trap setup and its application within a cold atomic quantum sensor is described. First qualification efforts on adhesive micro-integration technologies are presented. These tests are conducted in application-relevant geometries and material combinations common for micro-integrated optical setups. Adhesive aging will be investigated by thermal cycling or gamma radiation exposure. For vacuum compatibility testing, a versatile UHV testing system is currently being set up, enabling residual gas analysis and measurement of total gas rates down to 5•10-10mbar l/s at a base pressure of 10-11 mbar, exceeding the common ASTM E595 test.
Cold atoms are excellent metrological tools; they currently realize SI time and, soon, SI pressure in the ultra-high (UHV) and extreme high vacuum (XHV) regimes. The development of primary, vacuum metrology based on cold atoms currently falls under the purview of national metrology institutes. Under the emerging paradigm of the "quantum-SI", these technologies become deployable (relatively easy-to-use sensors that integrate with other vacuum chambers), providing a primary realization of the pascal in the UHV and XHV for the end-user. Here, we discuss the challenges that this goal presents. We investigate, for two different modes of operation, the expected corrections to the ideal cold-atom vacuum gauge and estimate the associated uncertainties. Finally, we discuss the appropriate choice of sensor atom, the light Li atom rather than the heavier Rb.