Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

Improvement of phase sensitivity in SU(1,1) interferometer using number-conserving operations

Jie Tang, Jiahao Li, Yuexiang Cao, Ying Liu, HaoRan Hu, Ya Wang, Dan Wu, Zhi-Feng Deng, Huicun Yu, XingYu Wang, Huazhi Lun, Jiahua Wei, Lei Shi

Published Feb 9, 2024• 5 citations
Publisher

Abstract

We propose a theoretical scheme to improve the phase sensitivity by introducing the number-conserving generalized superposition of product into squeezed thermal state of the traditional SU(1,1) interferometer with intensity detection. We investigate the effect of different parameter and photon losses on phase sensitivity under the condition of the ideal and the realistic phase estimation process, respectively. Moreover, compared with the previous methods, our scheme can not only enhance the phase sensitivity, but also significantly suppress the photon losses with only first-order GSP operation. It means that our scheme needs less resources and less operations to obtain higher phase sensitivity. These above results indicate that our scheme is viable in the phase sensitivity improvement, which may have practical applications in quantum information processing.

DOI
10.1016/j.rinp.2024.107465

Related papers

Phase estimation of an SU(1,1) interferometer with a coherent superposition squeezed vacuum in a realistic case

Youke Xu, Shoukang Chang, Cunjin Liu +2 more

The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.

Optics Express•Sep 22, 2022•11 citations

Improving phase estimation using number-conserving operations

Huan Zhang, Wei Ye, Chaoping Wei +3 more

We propose a theoretical scheme to improve the resolution and precision of phase measurement with parity detection by using a nonclassical state generated by applying a number-conserving generalized superposition of products (GSP) operation, ${\left(sa{a}^{\ifmmode\dagger\else\textdagger\fi{}}+t{a}^{\ifmmode\dagger\else\textdagger\fi{}}a\right)}^{m}$ with ${s}^{2}+{t}^{2}=1$, on a two-mode squeezed vacuum (TMSV) state as the input of Mach-Zehnder interferometer. Then, the statistical properties of the proposed GSP-TMSV are investigated via average photon number (APN), antibunching effect, and two-mode squeezing. Particularly, both higher order $m$ GSP operation and lower proportion parameter $s$ are beneficial for presenting larger total APN, which leads to the improvement of quantum Fisher information (QFI). In addition, we also compare the phase measurement precisions with and without photon losses between our scheme and the previous photon subtraction or photon addition schemes. It is found that our scheme, especially for the case of $s=0$, even in the presence of photon losses, has the best performance via the enhanced phase resolution, sensitivity, and QFI when compared to those previous schemes. Interestingly, without losses, the standard quantum-noise limit (SQL) is always broken through for our scheme and the phase uncertainty associated with the state of our scheme is closer to the corresponding Heisenberg limit (HL) than the TMSV in the larger total APN region, especially for the case of two-side GSP operation $\left(m,n\right)\ensuremath{\in}\left(1,1\right)$. However, in the presence of photon losses, the HL cannot be beaten, but the SQL can be broken through, particularly for the large total APN regimes.

arXiv:2012.02441•Physical Review A•May 5, 2021•26 citations

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

Tao Jiang, Zekun Zhao, Qingqian Kang +4 more

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

arXiv:2410.17612•Optics Express•Apr 14, 2025•8 citations

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Qingqian Kang, Zekun Zhao, Teng Zhao +2 more

Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.

arXiv:2410.21292•Frontiers of Physics•Jan 1, 2025•4 citations

Phase sensitivity of an SU(1,1) interferometer in photon-loss via photon operations

Youke Xu, Teng Zhao, Qingqian Kang +3 more

We study the phase sensitivity of an SU(1,1) interferometer with photon loss by using three different photon operations schemes, i.e., performing photon-addition operation on the input port of the SU(1,1) interferometer (Scheme A), the interior of SU(1,1) interferometer (Scheme B), and both of them (Scheme C). We compare the performance of the three schemes in phase estimation by performing the same times of photon-addition operation to the mode b. The results show that Scheme B improves the phase sensitivity best in ideal case, and Scheme C performs well against internal loss, especially in the case of strong loss. All the three schemes can beat the standard quantum limit in the presence of photon loss, but Scheme B and Scheme C can break through the standard quantum limit in a larger loss range.

Optics Express•Feb 8, 2023•23 citations

Phase estimation via a number-conserving operation inside a SU(1,1) interferometer

Qingqian Kang, Zekun Zhao, Teng Zhao +2 more

Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing a number-conserving operation (NCO), i.e., $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ and ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$, inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of the NCO on the phase sensitivity, the quantum Fisher information (QFI), and the quantum Cram\'er-Rao bound under both ideal and photon-loss scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the QFI and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme exhibits superior improvement in both the ideal and photon-loss cases in terms of phase sensitivity. Moreover, in the ideal case, the $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ scheme slightly outperforms the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme in terms of the QFI. However, in the presence of high photon losses, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme demonstrates a greater advantage.

arXiv:2406.06528•Physical Review A•Aug 23, 2024•13 citations
We propose a theoretical scheme to improve the phase sensitivity by introducing the number-conserving generalized superposition of product into squeezed thermal state of the traditional SU(1,1) interferometer with intensity detection. We investigate the effect of different parameter and photon losses on phase sensitivity under the condition of the ideal and the realistic phase estimation process, respectively. Moreover, compared with the previous methods, our scheme can not only enhance the phase sensitivity, but also significantly suppress the photon losses with only first-order GSP operation. It means that our scheme needs less resources and less operations to obtain higher phase sensitivity. These above results indicate that our scheme is viable in the phase sensitivity improvement, which may have practical applications in quantum information processing.
The phase sensitivity of SU(1,1) interferometer is investigated using a coherent state and an m-coherent superposition squeezed vacuum states as inputs and the intensity detection. Photon-subtraction, photon-addition and photon superposition are three special cases. Both ideal and realistic cases are considered. It is shown that the coefficient s of coherent superposition can modulate the performance of phase sensitivity, especially in a small squeezing region. Even in the presence of photon losses, the three-kind of non-Gaussian operations can achieve the improvement of measure precision, and the photon addition presents the best robustness compared to the photon subtraction and coherent superposition. For small squeezing, the first-order non-Gaussian operation may be the most preferred in improving phase sensitivity if considering the limitations of experimental conditions. Our results may be helpful for the practical application of quantum information.
We propose a theoretical scheme to improve the resolution and precision of phase measurement with parity detection by using a nonclassical state generated by applying a number-conserving generalized superposition of products (GSP) operation, ${\left(sa{a}^{\ifmmode\dagger\else\textdagger\fi{}}+t{a}^{\ifmmode\dagger\else\textdagger\fi{}}a\right)}^{m}$ with s2+t2=1{s}^{2}+{t}^{2}=1s2+t2=1, on a two-mode squeezed vacuum (TMSV) state as the input of Mach-Zehnder interferometer. Then, the statistical properties of the proposed GSP-TMSV are investigated via average photon number (APN), antibunching effect, and two-mode squeezing. Particularly, both higher order mmm GSP operation and lower proportion parameter sss are beneficial for presenting larger total APN, which leads to the improvement of quantum Fisher information (QFI). In addition, we also compare the phase measurement precisions with and without photon losses between our scheme and the previous photon subtraction or photon addition schemes. It is found that our scheme, especially for the case of s=0s=0s=0, even in the presence of photon losses, has the best performance via the enhanced phase resolution, sensitivity, and QFI when compared to those previous schemes. Interestingly, without losses, the standard quantum-noise limit (SQL) is always broken through for our scheme and the phase uncertainty associated with the state of our scheme is closer to the corresponding Heisenberg limit (HL) than the TMSV in the larger total APN region, especially for the case of two-side GSP operation $\left(m,n\right)\ensuremath{\in}\left(1,1\right)$. However, in the presence of photon losses, the HL cannot be beaten, but the SQL can be broken through, particularly for the large total APN regimes.
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.
Compared with passive interferometers, SU(1,1) interferometers demonstrate superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. Nevertheless, the measurement precision of these interferometers is considerably impacted by photon losses, particularly internal losses, thereby restricting the overall accuracy of measurements. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the available resources in quantum metrology, squeezing stands out as one of the most practical and efficient approaches. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the impact of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can significantly enhance the phase sensitivity and QFI by strengthening intramode correlations while weakening intermode correlations, thereby effectively improving the robustness of the SU(1,1) interferometer against photon losses.
We study the phase sensitivity of an SU(1,1) interferometer with photon loss by using three different photon operations schemes, i.e., performing photon-addition operation on the input port of the SU(1,1) interferometer (Scheme A), the interior of SU(1,1) interferometer (Scheme B), and both of them (Scheme C). We compare the performance of the three schemes in phase estimation by performing the same times of photon-addition operation to the mode b. The results show that Scheme B improves the phase sensitivity best in ideal case, and Scheme C performs well against internal loss, especially in the case of strong loss. All the three schemes can beat the standard quantum limit in the presence of photon loss, but Scheme B and Scheme C can break through the standard quantum limit in a larger loss range.
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing a number-conserving operation (NCO), i.e., $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ and ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$, inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of the NCO on the phase sensitivity, the quantum Fisher information (QFI), and the quantum Cram\'er-Rao bound under both ideal and photon-loss scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the QFI and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme exhibits superior improvement in both the ideal and photon-loss cases in terms of phase sensitivity. Moreover, in the ideal case, the $a{a}^{\ifmmode\dagger\else\textdagger\fi{}}$ scheme slightly outperforms the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme in terms of the QFI. However, in the presence of high photon losses, the ${a}^{\ifmmode\dagger\else\textdagger\fi{}}a$ scheme demonstrates a greater advantage.