Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.
Wide-range high-precision velocity detection with nitrogen-vacancy (NV) color center has been realized. By treating the NV color center as a mixer, the high-precision microwave measurement is realized. Through optimization of acquisition time, the microwave frequency resolution is improved to the mHz level. Combined with the frequency-velocity conversion model, velocity detection is realized in the range of 0-100 cm/s, and the velocity resolution is up to 0.012 cm/s. The maximum deviation in repeated measurements does not exceed 1/1000. Finally, combined with the multiplexed microwave reference technique, the range of velocity can be extended to 7.4 × 10 5 m/s. All of the results provide reference for high-precision velocity detection and play a significant role in various domains of quantum precision measurement. This study provides a crucial technical foundation for the development of high-dynamic-range velocity detectors and novel quantum precision velocity measurement technologies.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
Angle of Arrival (AoA) detection plays a pivotal role in wireless communication, target localization, and remote sensing navigation, demonstrating significant importance and extensive application potential. This study introduces a microwave AoA measurement method based on a solid-state quantum spin nitrogen-vacancy (NV) center receiver, which has tunable microwave frequency response. By integrating microwave heterodyne detection with an electron spin model, the proposed approach achieves high-precision microwave phase measurement. Exploiting the functional relationship between phase and incident angle, accurate AoA sensing is realized. Furthermore, leveraging the magnetic field-tuned resonance characteristics of NV centers, a microwave AoA measurement system capable of accommo-dating diverse detection frequency bands is constructed. Experimental validation at multiple operating frequencies confirms the system’s frequency reconfigurability, stability, and reliability. Results indicate that within the tested range of 40° to 140°, the AoA measurements exhibit the smallest deviation of 0.62° at an incident angle of 90°, while the largest deviation of 4.58° is observed at an incident angle of 140°. Long-term heterodyne measurements further verify the phase stability of the proposed detection scheme. These findings provide crucial experimental evidence for the application of quantum technology in electromagnetic target identification, navigation, and localization, while laying a robust foundation for the development of miniaturized and integrated AoA quantum measurement systems.
This study introduces a novel method for the simultaneous detection of microwave sensor power and temperature, leveraging nitrogen-vacancy (NV) centers as a robust quantum system. Through precise measurement of the optical detection magnetic resonance contrast in NV centers, the microwave power is accurately determined. Furthermore, the temperature of the sensor is obtained by monitoring the variations in zero-field splitting and thorough spectral analysis. This method enables the efficient real-time acquisition of synchronized data on both microwave power and temperature from the sensor, facilitating concurrent monitoring without the necessity of additional sensing devices. Finally, we verified that the magnetic sensitivity of the system is approximately 1.2 nT/Hz1/2, and the temperature sensitivity is around 0.38 mK/Hz1/2. The minimum resolution of microwave power is about 20 nW. The experimental results demonstrate that this quantum measurement technique provides stable and accurate data across a wide range of microwave power and temperature conditions. These findings indicate substantial potential for this technique in advanced applications such as aerospace, medical diagnostics, and high-frequency communications. Future studies will aim to extend the industrial applicability of this method by refining quantum control techniques within NV center systems.
Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.
This article presents a frequency measurement method for spatial microwave signals with solid‐state atom resonance, performing measurements based on the burnt hole in spectrum with two microwave fields acting on nitrogen vacancies (NVs) simultaneously. The population on |0⟩ of the NV color center in the ground state affected by the resonance of two microwave fields with similar frequencies responds excellently to external microwave frequencies, and a phenomenon named hole burning occurs. The full width at half maximum (FWHM) of the resonant peak at the hole is 18.9 kHz. When microwaves of different frequencies are applied, the resonant peak precisely follows the signal frequency in the experiment. Subsequently, the resonant peak is processed using the differential method to obtain a frequency measurement error on the order of 100 Hz. The spatial resolution of this method is within the millimeter scale. This study can provide technical support for applications in microwave frequency measurement and spatial mapping with quantum precision measurement.
The efficient and reliable detection of microwave signals is a key element of the breakthrough in new-generation communication technology. In this article, we proposed an approach for the simultaneous identification of multiple microwave signals in a continuous frequency range based on the spectral hole-burning effect of nitrogen-vacancy (NV) centers. The protocol combines the quantum wide-field imaging method with magnetic gradient means, breaking the narrowband and discrete detection limitations of conventional optically detected magnetic resonance (ODMR) techniques. The frequencies of multiple microwave signals can be accurately decoupled by locating the relevant gaps on resonance frequency curves. Meanwhile, the effects induced by fixed-frequency signals with different powers on the resonance frequency curves were systematically analyzed. The experimental results indicated that the system realized a multiple-frequency resolution of 1 MHz and a minimum detectable power of 1 mW over a continuous bandwidth of 313-MHz. This proposal is capable of real-time and simultaneous detection of multiple microwave signals, which remarkably improves the utilization efficiency of spectrum resources.