Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers in Optics

Optical Coherence Tomography with Undetected Photons Based on an Integrated PDC Source

Franz Roeder, René Pollmann, Michael Stefszky, Matteo Santandrea, Kai Hong Luo, Victor Quiring, Raimund Ricken, Christof Eigner, Benjamin Brecht, Christine Silberhorn

Published Jan 1, 2023• 0 citations
Publisher

Abstract

We present an optical coherence tomography scheme with undetected photons in an SU(1,1) interferometer based on an integrated nonlinear waveguide. We achieve an axial resolution of < 0.2mm in the time domain and implement differential pumping to compensate for losses in the interferometer.
DOI
10.1364/fio.2023.jtu5a.55

Related papers

Optimized OCT with Undetected Photons Based on an Integrated Waveguide PDC Source

Franz Roeder, René Pollmann, Michael Stefszky +5 more

We present the experimental realization of an optical coherence tomography scheme with undetected photons using a nonlinear waveguide in an SU(1,1)-interferometer. A differential pumping scheme is investigated and incorporated to optimize the measured interferograms.

Quantum 2.0 Conference and Exhibition•Jan 1, 2024•0 citations

Dispersion in nonlinear interferometry: implications for optical coherence tomography with undetected photons

Ivan Zorin, Paul Gattinger

Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function (PSF) in optical coherence tomography (OCT) with undetected photons; and physical compensation is less straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-IR spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is compared with an alternative numerical technique. The results demonstrate a 2.2-fold improvement in axial resolution and outperform the alternative correction method in overall imaging performance.

physics.opticsCross-listedarXiv:2602.05653•Journal of Physics Photonics•Feb 6, 2026•2 citations

Towards an Integrated Sensor for Optimized OCT with Undetected Photons

Franz Roeder, René Pollmann, Viktor Quiring +3 more

The development of practical quantum sensors requires integration. We demonstrate that nonlinear integrated interferometers based on guided-wave PDC processes bene-fit from implementation in the induced coherence geometry instead of the commonly used SU(1,1) geometry for quantum OCT measurements with undetected photons.

Quantum 2.0 Conference and Exhibition•Jan 1, 2025•2 citations

Dual Pump Wavelength Frequency-Domain Optical Coherence Tomography with undetected Mid-infrared Photons

Rajshree Swarnkar, Marlon Placke, Aron Vanselow +2 more

We implement a mid-infrared optical coherence tomography in a nonlinear optical interferometer using two different pump wavelengths for spontaneous parametric down conversion to enhance its axial resolution for the depth scans of highly scattering materials.

Quantum 2.0 Conference and Exhibition•Jan 1, 2024•0 citations

Optical coherence tomography with a nonlinear interferometer in the high parametric gain regime

Gerard J. Machado, Gaetano Frascella, Juan P. Torres +1 more

We demonstrate optical coherence tomography based on an SU(1,1) nonlinear interferometer with high-gain parametric downconversion. For imaging and sensing applications, this scheme promises to outperform previous experiments working at low parametric gain, since higher photon fluxes provide lower integration times for obtaining high-quality images. In this way, one can avoid using single-photon detectors or CCD cameras with very high sensitivities, and standard spectrometers can be used instead. Other advantages are higher sensitivity to small loss and amplification before detection so that the detected light power considerably exceeds the probing one.

arXiv:2006.02314•Applied Physics Letters•Aug 31, 2020•49 citations

Frequency-domain optical coherence tomography with undetected mid-infrared photons

Aron Vanselow, Paul Kaufmann, Ivan Zorin +3 more

Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

arXiv:2006.07400•Optica•Oct 28, 2020•112 citations
Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function (PSF) in optical coherence tomography (OCT) with undetected photons; and physical compensation is less straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-IR spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is compared with an alternative numerical technique. The results demonstrate a 2.2-fold improvement in axial resolution and outperform the alternative correction method in overall imaging performance.
We demonstrate optical coherence tomography based on an SU(1,1) nonlinear interferometer with high-gain parametric downconversion. For imaging and sensing applications, this scheme promises to outperform previous experiments working at low parametric gain, since higher photon fluxes provide lower integration times for obtaining high-quality images. In this way, one can avoid using single-photon detectors or CCD cameras with very high sensitivities, and standard spectrometers can be used instead. Other advantages are higher sensitivity to small loss and amplification before detection so that the detected light power considerably exceeds the probing one.
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.