Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chip

Traveling-wave parametric amplifier–induced qubit dephasing: analysis and mitigation

Yingshan Zhang, Huikai Xu, Yu Hao Song, Yuqun Xu, Shuang Yang, Ziyue Hua, Shoukuan Zhao, Weiyang Liu, Guangming Xue, Yirong Jin, Haifeng Yu

Published Sep 28, 2023• 6 citations
Publisher

Abstract

The mitigation of dephasing poses a significant challenge in improving the performance of error-prone superconducting quantum computing systems. Here, we investigate the dephasing of a transmon qubit in a dispersive readout regime using a Josephson travelling-wave parametric amplifier as the preamplifier. Our findings reveal that the potent pump leakage from the preamplifier may lead to severe dephasing. This issue could be attributed to a mixture of measurement-induced dephasing, ac Stark effect, and heating. We show that pulse-mode readout is a promising measurement scheme to mitigate qubit dephasing while minimizing the need for bulky circulators. Our work provides key insights into mitigating decoherence from microwave-pumped preamplifiers, which will be critical for advancing large-scale quantum computers.

DOI
10.1016/j.chip.2023.100067

Related papers

Intermodulation Distortion in a Josephson Traveling-Wave Parametric Amplifier

Ants Remm, Sebastian Krinner, Nathan Lacroix +5 more

Josephson traveling-wave parametric amplifiers (TWPAs) enable the amplification of weak microwave signals close to the quantum limit with large bandwidth, which has a broad range of applications in superconducting quantum computing and in the operation of single-photon detectors. While the large bandwidth allows for their use in frequency-multiplexed detection architectures, an increased number of readout tones per amplifier puts more stringent requirements on the dynamic range to avoid saturation. Here, we characterize the undesired mixing processes between the different frequency-multiplexed tones applied to a Josephson TWPA, a phenomenon also known as intermodulation distortion. The effect becomes particularly significant when the amplifier is operated close to its saturation power. Furthermore, we demonstrate that intermodulation distortion can lead to significant crosstalk and reduction of fidelity for multiplexed readout of superconducting qubits. We suggest using large detunings between the pump and signal frequencies to mitigate crosstalk. Our work provides insights into the limitations of current Josephson TWPAs and highlights the importance of performing further research on these devices.

arXiv:2210.04799•Physical Review Applied•Sep 13, 2023•24 citations

Characterisation of a travelling-wave parametric amplifier for improved qubit measurements

Hampus Renberg Nilsson

In order to build a large-scale quantum computer, one of the requirements is high-fidelity multiplexed qubit readout, which in turn relies on the use of ultralow-noise amplifiers. While Josephson Parametric Amplifiers (JPAs), using a cavity with few Josephson junctions, have shown promising results for single qubit readout, they have limitations such as low saturation power and a gain-bandwidth product restriction. This makes them less suited for frequency multiplexed qubit readout. A current-pumped Josephson Travelling-Wave Parametric Amplifier (JTWPA), using 4-wave mixing in a lumped-element transmission line, features both high saturation power as well as no restriction on large bandwidth and high gain. This is possible due to multiple junctions and the lack of a cavity. However, also this current pumped JTWPA has an inherent problem, namely phase mismatch between the pump and the signal. This prevents exponential gain. In this thesis, a current pumped JTWPA using the resonant phase matching (RPM) technique to reduce the phase mismatch problem is studied and characterised. The JTWPA shows high gain, high saturation power and a large signal-to-noise ratio improvement. The JTWPA is also used for qubit readout, for which it clearly improves the readout fidelity.

•Jan 1, 2019•0 citations

Circuit Design and Experimental Characterization of a Josephson Traveling-Wave Parametric Amplifier

Christoph Kissling

Bringing signals from quantum to classical, from few-photon to many-photon levels for further processing, is a common challenge in rising quantum technologies. These include quantum computing, quantum communication, quantum sensing, radio astronomy, and dark matter searches, typically operating at microwave frequencies and millikelvin temperatures. Superconducting parametric amplifiers, as the first piece in the readout chain, have become a cornerstone of these technologies, since they offer unrivaled noise performance near the quantum-mechanical limit and high gain to surpass the noise of subsequent amplifiers. A notable implementation is the Josephson traveling-wave parametric amplifier (TWPA), which stands out due to its bandwidth of several Gigahertz and high saturation power, often larger than -100 dBm. These key properties come at the cost of complexity in design and fabrication: TWPA metamaterials often contain several thousands of Josephson junctions. Designing high-gain TWPAs involves three major challenges: ensuring impedance-matching, phase-matching of parametric amplification, and suppressing unwanted processes, all achievable through sub-wavelength dispersion engineering. This thesis covers the circuit design and analysis, implementation, and experimental characterization of a dispersion-engineered TWPA based on radio-frequency superconducting interference devices (rf-SQUIDs). It focuses on a detailed investigation of dispersion-engineering techniques and their effects on amplifier performance, particularly through the use of time-domain circuit simulations to analyze the multimode dynamics of the circuit. The experimentally realized device features 18 dB of gain, an instantaneous bandwidth spanning from 2.2 to 6.7 GHz, a system noise of 2.5 quanta, and a saturation power of (−86.5 ± 4.0) dBm. With these characteristics, it is suitable for frequency-multiplexed readout of detector arrays or qubits. Its high saturation power, about 10 dB higher than other reported Josephson-junction-based TWPAs, allows increasing the number of qubits per readout line, or decreasing the intermodulation between frequency-multiplexed qubits, both crucial for scaling up quantum computation.

•Feb 24, 2026•0 citations

Characterization and Control of Measurement-Induced Dephasing on Superconducting Flux Qubit with a Josephson Bifurcation Amplifier

Kosuke Kakuyanagi, Yuichiro Matsuzaki, Tatsuya Baba +3 more

Quantum measurements play a central role in quantum information processing. Understanding the mechanism of the quantum measurements is essential to both improve the visibility of the readout and decrease the projection error during measurement. Here, we describe and demonstrate an experimental protocol for quantifying a measurement backaction when we readout a superconducting flux qubit using a Josephson bifurcation amplifier. The coupling with the Josephson bifurcation amplifier induces a dephasing on the flux qubit during the readout. We have succeeded in estimating and controlling the strength of such a measurement-induced dephasing by changing the pulse height of the microwave driving. Our results are crucial for designing a suitable quantum readout technique for the realization of practical quantum devices.

Journal of the Physical Society of Japan•Sep 6, 2016•3 citations

Gain compression in Josephson traveling-wave parametric amplifiers

Gwenael Le Gal, Guilliam Butseraen, Arpit Ranadive +6 more

Superconducting traveling-wave parametric amplifiers (TWPAs) are increasingly used in various applications, including quantum computing, quantum sensing, and dark matter detection. However, one important characteristic of these amplifiers, gain compression, has not received much attention. As a result, there is a lack of comprehensive experimental exploration of this phenomenon in the existing literature. In this study, we present an experimental investigation of gain compression in a Josephson traveling-wave parametric amplifier based on a four-wave mixing process. We have implemented a novel setup to monitor the complex transmission of both the pump and signal tones, which allows us to simultaneously track pump depletion and signal amplification as functions of signal power and frequency across the entire bandwidth of the device. Our findings indicate that, while pump depletion occurs during gain compression, it is not the only mechanism involved in the saturation of a TWPA. Power-induced phase-matching processes also take place within the device. This study provides valuable insights for optimizing TWPAs for applications that require high total input power, such as multiplexed qubit readout or broadband photon emission.

arXiv:2502.03022•Physical Review Applied•Jun 4, 2025•6 citations

Field-induced phase-matching in Josephson traveling wave parametric amplifiers

Daniil E. Bazulin, S. Gandorfer, N. Bruckmoser +9 more

Superconducting Josephson traveling wave parametric amplifiers (JTWPAs) enable broadband, quantum-limited amplification of weak microwave signals. JTWPAs are essential for the single-shot readout of superconducting qubits, broadband vacuum squeezing, or the generation of microwave cluster states. Phase-matching between signal and pump modes in such JTWPAs represents a major engineering challenge, which is typically solved by integrating resonators in a nonlinear medium in order to tailor electromagnetic dispersion relations and achieve a broadband, high-gain amplification. Here, we experimentally demonstrate a phase-matching approach using a homogeneous nonlinear medium based on Josephson elements by exploiting a magnetic field inhomogeneity. We show how the latter may lead to the sign reversal of the 3-wave mixing nonlinearity and stabilization of the parametric amplification. We envision this technique as a viable alternative to conventional phase-matching approaches.

arXiv:2611.13084•Nov 9, 2026•0 citations
The mitigation of dephasing poses a significant challenge in improving the performance of error-prone superconducting quantum computing systems. Here, we investigate the dephasing of a transmon qubit in a dispersive readout regime using a Josephson travelling-wave parametric amplifier as the preamplifier. Our findings reveal that the potent pump leakage from the preamplifier may lead to severe dephasing. This issue could be attributed to a mixture of measurement-induced dephasing, ac Stark effect, and heating. We show that pulse-mode readout is a promising measurement scheme to mitigate qubit dephasing while minimizing the need for bulky circulators. Our work provides key insights into mitigating decoherence from microwave-pumped preamplifiers, which will be critical for advancing large-scale quantum computers.
Josephson traveling-wave parametric amplifiers (TWPAs) enable the amplification of weak microwave signals close to the quantum limit with large bandwidth, which has a broad range of applications in superconducting quantum computing and in the operation of single-photon detectors. While the large bandwidth allows for their use in frequency-multiplexed detection architectures, an increased number of readout tones per amplifier puts more stringent requirements on the dynamic range to avoid saturation. Here, we characterize the undesired mixing processes between the different frequency-multiplexed tones applied to a Josephson TWPA, a phenomenon also known as intermodulation distortion. The effect becomes particularly significant when the amplifier is operated close to its saturation power. Furthermore, we demonstrate that intermodulation distortion can lead to significant crosstalk and reduction of fidelity for multiplexed readout of superconducting qubits. We suggest using large detunings between the pump and signal frequencies to mitigate crosstalk. Our work provides insights into the limitations of current Josephson TWPAs and highlights the importance of performing further research on these devices.
In order to build a large-scale quantum computer, one of the requirements is high-fidelity multiplexed qubit readout, which in turn relies on the use of ultralow-noise amplifiers. While Josephson Parametric Amplifiers (JPAs), using a cavity with few Josephson junctions, have shown promising results for single qubit readout, they have limitations such as low saturation power and a gain-bandwidth product restriction. This makes them less suited for frequency multiplexed qubit readout. A current-pumped Josephson Travelling-Wave Parametric Amplifier (JTWPA), using 4-wave mixing in a lumped-element transmission line, features both high saturation power as well as no restriction on large bandwidth and high gain. This is possible due to multiple junctions and the lack of a cavity. However, also this current pumped JTWPA has an inherent problem, namely phase mismatch between the pump and the signal. This prevents exponential gain. In this thesis, a current pumped JTWPA using the resonant phase matching (RPM) technique to reduce the phase mismatch problem is studied and characterised. The JTWPA shows high gain, high saturation power and a large signal-to-noise ratio improvement. The JTWPA is also used for qubit readout, for which it clearly improves the readout fidelity.
Bringing signals from quantum to classical, from few-photon to many-photon levels for further processing, is a common challenge in rising quantum technologies. These include quantum computing, quantum communication, quantum sensing, radio astronomy, and dark matter searches, typically operating at microwave frequencies and millikelvin temperatures. Superconducting parametric amplifiers, as the first piece in the readout chain, have become a cornerstone of these technologies, since they offer unrivaled noise performance near the quantum-mechanical limit and high gain to surpass the noise of subsequent amplifiers. A notable implementation is the Josephson traveling-wave parametric amplifier (TWPA), which stands out due to its bandwidth of several Gigahertz and high saturation power, often larger than -100 dBm. These key properties come at the cost of complexity in design and fabrication: TWPA metamaterials often contain several thousands of Josephson junctions. Designing high-gain TWPAs involves three major challenges: ensuring impedance-matching, phase-matching of parametric amplification, and suppressing unwanted processes, all achievable through sub-wavelength dispersion engineering. This thesis covers the circuit design and analysis, implementation, and experimental characterization of a dispersion-engineered TWPA based on radio-frequency superconducting interference devices (rf-SQUIDs). It focuses on a detailed investigation of dispersion-engineering techniques and their effects on amplifier performance, particularly through the use of time-domain circuit simulations to analyze the multimode dynamics of the circuit. The experimentally realized device features 18 dB of gain, an instantaneous bandwidth spanning from 2.2 to 6.7 GHz, a system noise of 2.5 quanta, and a saturation power of (−86.5 ± 4.0) dBm. With these characteristics, it is suitable for frequency-multiplexed readout of detector arrays or qubits. Its high saturation power, about 10 dB higher than other reported Josephson-junction-based TWPAs, allows increasing the number of qubits per readout line, or decreasing the intermodulation between frequency-multiplexed qubits, both crucial for scaling up quantum computation.
Quantum measurements play a central role in quantum information processing. Understanding the mechanism of the quantum measurements is essential to both improve the visibility of the readout and decrease the projection error during measurement. Here, we describe and demonstrate an experimental protocol for quantifying a measurement backaction when we readout a superconducting flux qubit using a Josephson bifurcation amplifier. The coupling with the Josephson bifurcation amplifier induces a dephasing on the flux qubit during the readout. We have succeeded in estimating and controlling the strength of such a measurement-induced dephasing by changing the pulse height of the microwave driving. Our results are crucial for designing a suitable quantum readout technique for the realization of practical quantum devices.
Superconducting traveling-wave parametric amplifiers (TWPAs) are increasingly used in various applications, including quantum computing, quantum sensing, and dark matter detection. However, one important characteristic of these amplifiers, gain compression, has not received much attention. As a result, there is a lack of comprehensive experimental exploration of this phenomenon in the existing literature. In this study, we present an experimental investigation of gain compression in a Josephson traveling-wave parametric amplifier based on a four-wave mixing process. We have implemented a novel setup to monitor the complex transmission of both the pump and signal tones, which allows us to simultaneously track pump depletion and signal amplification as functions of signal power and frequency across the entire bandwidth of the device. Our findings indicate that, while pump depletion occurs during gain compression, it is not the only mechanism involved in the saturation of a TWPA. Power-induced phase-matching processes also take place within the device. This study provides valuable insights for optimizing TWPAs for applications that require high total input power, such as multiplexed qubit readout or broadband photon emission.
Superconducting Josephson traveling wave parametric amplifiers (JTWPAs) enable broadband, quantum-limited amplification of weak microwave signals. JTWPAs are essential for the single-shot readout of superconducting qubits, broadband vacuum squeezing, or the generation of microwave cluster states. Phase-matching between signal and pump modes in such JTWPAs represents a major engineering challenge, which is typically solved by integrating resonators in a nonlinear medium in order to tailor electromagnetic dispersion relations and achieve a broadband, high-gain amplification. Here, we experimentally demonstrate a phase-matching approach using a homogeneous nonlinear medium based on Josephson elements by exploiting a magnetic field inhomogeneity. We show how the latter may lead to the sign reversal of the 3-wave mixing nonlinearity and stabilization of the parametric amplification. We envision this technique as a viable alternative to conventional phase-matching approaches.