Physical Review A

Fundamental limit of bandwidth-extrapolation-based superresolution

Yunkai Wang, Virginia O. Lorenz

Published Jul 5, 2023• 3 citations
Publisher

Abstract

Here we relate two methods of subdiffraction imaging: bandwidth extrapolation for spatially bounded sources and quantum-metrology-inspired methods under assumptions about source structure. We present a quantum estimation theoretical approach in which the source is modeled in terms of unknown parameters corresponding to the Fourier components, whose impact on resolution is very intuitive. Using this method, we find that imaging spatially bounded sources faces an unavoidable fundamental resolution limit, but that in the small-source limit, certain measurement approaches can significantly improve the sensitivity over conventional methods.

DOI
10.1103/physreva.108.012602

Related papers

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•14 citations

Super-resolution with Fourier measurements

S. A. Wadood, Shaurya Aarav, Kevin Liang +1 more

Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem ${x_1,x_2}$ in the near field corresponds to the single-point wavenumber problem $k\ =2π/(x_2-x_1)$ in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of $N$ sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.

physics.opticsCross-listedarXiv:2511.06098•Nov 11, 2025•2 citations

Ultra-sensitive separation estimation of optical sources

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrology-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite–Gauss basis. Analyzing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.

arXiv:2306.11916•Optica•Nov 10, 2023•51 citations

Quantum limits to optical point-source localization

Mankei Tsang

Motivated by the importance of optical microscopes to science and engineering, scientists have pondered for centuries how to improve their resolution and the existence of fundamental resolution limits. In recent years, a new class of microscopes that overcome a long-held belief about the resolution have revolutionized biological imaging. Termed "superresolution" microscopy, these techniques work by accurately locating optical point sources from far field. To investigate the fundamental localization limits, here I derive quantum lower bounds on the error of locating point sources in free space, taking full account of the quantum, nonparaxial, and vectoral nature of photons. These bounds are valid for any measurement technique, as long as it obeys quantum mechanics, and serve as general no-go theorems for the resolution of microscopes. To arrive at analytic results, I focus mainly on the cases of one and two classical monochromatic sources with an initial vacuum optical state. For one source, a lower bound on the root-mean-square position estimation error is on the order of $λ_0/\sqrt{N}$, where $λ_0$ is the free-space wavelength and $N$ is the average number of radiated photons. For two sources, owing to the statistical effect of nuisance parameters, the error bound diverges when their radiated fields overlap significantly. The use of squeezed light to enhance further the accuracy of locating one classical point source and the localization limits for partially coherent sources and single-photon sources are also discussed. The presented theory establishes a rigorous quantum statiscal inference framework for the study of superresolution microscopy and points to the possibility of using quantum techniques for true resolution enhancement.

arXiv:1411.2954•Optica•Jul 10, 2015•70 citations

Quantum-Limited Distance Estimation in Three-Dimensional Optical Superresolution

Junyan Li, Shengshi Pang

Quantum superresolution reveals that the vanishing of separation sensitivity in conventional imaging below the Rayleigh limit does not necessarily indicate a fundamental loss of information in the optical field. However, the quantum limit for estimating the physical distance between two incoherent point sources in three-dimensional imaging systems and its dependence on the spatial structure of the point-spread function remains largely unknown. In this work, we derive the quantum-limited precision for estimating the full distance between two incoherent point sources with arbitrary intensity imbalance in a three-dimensional spatially invariant imaging system. We show that the distance information remains finite in the sub-Rayleigh regime and is governed by the second-order displacement-response tensor of the point-spread function. The eigensystem of this tensor determines the optimal relative orientation between the two sources, and reflection symmetries of the point-spread function can further provide a simplified means of identifying the optimal orientation. This geometric structure is coordinate invariant and provides a direct strategy for improving resolution by physically rotating an anisotropic imaging system to align its optimal principal response direction with the source displacement. For a general three-dimensional Gaussian point-spread function, the response tensor is proportional to the inverse spatial covariance, establishing a direct connection between quantum-limited distance precision and the geometry of Gaussian distribution.

quant-pharXiv:2608.04876•Aug 6, 2026•0 citations

Quantum-inspired superresolution for incoherent imaging

Xiaojie Tan, Qi Luo, Lianwei Chen +3 more

Optical measurements that can achieve the fundamental quantum limits have the potential to improve the imaging of subdiffraction objects in important applications, including optical astronomy and fluorescence microscopy. Working towards the goal of implementing such quantum-inspired measurements for real applications, we experimentally demonstrate the localization of two incoherent optical point sources and the semiparametric estimation of object moments in the subdiffraction regime via spatial-mode demultiplexing (SPADE). In the case of two sources, we are able to estimate both of their locations accurately, not just their separation, by exploiting the asymmetric response of our SPADE device. In the case of semiparametric estimation, we demonstrate that, even if the source number is unknown, the moments of the source distribution can still be estimated accurately. Our demonstration paves the way towards the use of SPADE for optical superresolution in practical scenarios, where adaptive measurements are difficult and many parameters are unknown.

Optica•Jul 27, 2023•42 citations
Here we relate two methods of subdiffraction imaging: bandwidth extrapolation for spatially bounded sources and quantum-metrology-inspired methods under assumptions about source structure. We present a quantum estimation theoretical approach in which the source is modeled in terms of unknown parameters corresponding to the Fourier components, whose impact on resolution is very intuitive. Using this method, we find that imaging spatially bounded sources faces an unavoidable fundamental resolution limit, but that in the small-source limit, certain measurement approaches can significantly improve the sensitivity over conventional methods.
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect alignment with the centroid of the object. Both inhibit the practical application of these methods, as uniform motion and/or relative jitter destroy their assumptions. Here, we show that measuring intensity in the Fourier plane enables super-resolution without any of the issues of image-based methods. We start with the shift-invariance of the Fourier transform and the observation that the two-point position problem x1,x2{x_1,x_2}x1​,x2​ in the near field corresponds to the single-point wavenumber problem k =2π/(x2−x1)k\ =2π/(x_2-x_1)k =2π/(x2​−x1​) in the far field. We consider the full range of mutual coherence and show that for fully coherent sources, the Fourier method saturates the quantum limit, i.e. it gives the best possible measurement. Similar results hold for sub-Rayleigh constellations of NNN sources, which can act collectively as a spatially averaged metasurface and/or individually as elements of a phased-array antenna. The theory paves the way to merge Fourier optics with super-resolution techniques, enabling experimental devices that are both simpler and more robust than previous designs.
Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrology-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite–Gauss basis. Analyzing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.
Motivated by the importance of optical microscopes to science and engineering, scientists have pondered for centuries how to improve their resolution and the existence of fundamental resolution limits. In recent years, a new class of microscopes that overcome a long-held belief about the resolution have revolutionized biological imaging. Termed "superresolution" microscopy, these techniques work by accurately locating optical point sources from far field. To investigate the fundamental localization limits, here I derive quantum lower bounds on the error of locating point sources in free space, taking full account of the quantum, nonparaxial, and vectoral nature of photons. These bounds are valid for any measurement technique, as long as it obeys quantum mechanics, and serve as general no-go theorems for the resolution of microscopes. To arrive at analytic results, I focus mainly on the cases of one and two classical monochromatic sources with an initial vacuum optical state. For one source, a lower bound on the root-mean-square position estimation error is on the order of λ0/Nλ_0/\sqrt{N}λ0​/N​, where λ0λ_0λ0​ is the free-space wavelength and NNN is the average number of radiated photons. For two sources, owing to the statistical effect of nuisance parameters, the error bound diverges when their radiated fields overlap significantly. The use of squeezed light to enhance further the accuracy of locating one classical point source and the localization limits for partially coherent sources and single-photon sources are also discussed. The presented theory establishes a rigorous quantum statiscal inference framework for the study of superresolution microscopy and points to the possibility of using quantum techniques for true resolution enhancement.
Quantum superresolution reveals that the vanishing of separation sensitivity in conventional imaging below the Rayleigh limit does not necessarily indicate a fundamental loss of information in the optical field. However, the quantum limit for estimating the physical distance between two incoherent point sources in three-dimensional imaging systems and its dependence on the spatial structure of the point-spread function remains largely unknown. In this work, we derive the quantum-limited precision for estimating the full distance between two incoherent point sources with arbitrary intensity imbalance in a three-dimensional spatially invariant imaging system. We show that the distance information remains finite in the sub-Rayleigh regime and is governed by the second-order displacement-response tensor of the point-spread function. The eigensystem of this tensor determines the optimal relative orientation between the two sources, and reflection symmetries of the point-spread function can further provide a simplified means of identifying the optimal orientation. This geometric structure is coordinate invariant and provides a direct strategy for improving resolution by physically rotating an anisotropic imaging system to align its optimal principal response direction with the source displacement. For a general three-dimensional Gaussian point-spread function, the response tensor is proportional to the inverse spatial covariance, establishing a direct connection between quantum-limited distance precision and the geometry of Gaussian distribution.
Optical measurements that can achieve the fundamental quantum limits have the potential to improve the imaging of subdiffraction objects in important applications, including optical astronomy and fluorescence microscopy. Working towards the goal of implementing such quantum-inspired measurements for real applications, we experimentally demonstrate the localization of two incoherent optical point sources and the semiparametric estimation of object moments in the subdiffraction regime via spatial-mode demultiplexing (SPADE). In the case of two sources, we are able to estimate both of their locations accurately, not just their separation, by exploiting the asymmetric response of our SPADE device. In the case of semiparametric estimation, we demonstrate that, even if the source number is unknown, the moments of the source distribution can still be estimated accurately. Our demonstration paves the way towards the use of SPADE for optical superresolution in practical scenarios, where adaptive measurements are difficult and many parameters are unknown.