Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Research

Precision determination of the 5dD3/22 state lifetime of single Yb+174 ion

H. Shao, H. Yue, Zhiyao Ma, Yao Huang, H. Guan, K. Gao

Published Jun 27, 2023• 10 citations
Publisher

Abstract

We present a method to precisely determine the $^{2}D_{3/2}$ state lifetime of a single trapped $^{174}\mathrm{Yb}^{+}$ ion. This method is based on the detection of photons emitted from excited states, where a highly synchronized measurement sequence for laser control and an intensity-alternating sequence for atomic excitation and photon counting are used to minimize systematic errors. This method is easy to implement and is immune to fluctuations of magnetic field, laser intensity, and frequency detuning. Combined with the real-time approach of background photon correction, the radiative lifetime of the $^{2}D_{3/2}$ state is determined to be $54.83\ifmmode\pm\else\textpm\fi{}0.18$ ms, which represents an order of magnitude improvement in measurement precision. The accurately determined lifetime sets a benchmark for many-body atomic theories and is particularly useful to determine the coherence time limit of the optical clock.

DOI
10.1103/physrevresearch.5.023193

Related papers

Precision determination of dipole transition elements with a single ion

H. Shao, Y.-B. Tang, H.-L. Yue +6 more

In the field of quantum metrology, transition matrix elements are crucial for accurately evaluating the black-body radiation shift of the clock transition and the amplitude of the related parity-violating transition, and can be used as probes to test quantum electrodynamic effects, especially at the 10−3–10−4 level. We developed a universal experimental approach to precisely determine the dipole transition matrix elements by using the shelving technique, for the species where two transition channels are involved, in which the excitation pulses with increasing duration were utilized to induce shelving, and the resulting shelving probabilities were determined by counting the scattered photons from the excited P1/22 state to the S1/22 ground state. Using the scattered photons offers several advantages, including insensitivity to fluctuations in magnetic field, laser intensity, and frequency detuning. An intensity-alternating sequence to minimize detection noise and a real-time approach for background photon correction were implemented in parallel. We applied this technique to a single Yb+ ion, and determined the 6p P1/22-5d D23/2 transition matrix element 2.9979(20) ea0, which indicates an order of magnitude improvement over existing reports. By combining our result with the 6p P1/22 lifetime of 8.12(2) ns, we extracted the 6s S1/22-6p P1/22 transition matrix element to be 2.4703(31) ea0. The accurately determined dipole transition matrix elements can serve as a benchmark for the development of high-precision atomic many-body theoretical methods.

Photonics Research•Jul 23, 2024•2 citations

Precision measurement of the 3dD3/22 –state lifetime in a single trapped Ca+40

H. Shao, Yao Huang, H. Guan +2 more

We present a high-precision measurement of the $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}$--state lifetime in a single trapped $^{40}\mathrm{Ca}^{+}$. The measurement was performed using a high-efficiency quantum-state detection technique to monitor quantum jumps and a high-precision and highly synchronous measurement sequence for laser control. A feature in our measurement is the pumping rate of the 729-nm laser that was corrected in a real-time way. The $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}$--state lifetime was obtained through the measurement of the spontaneous decay rate after incoherent shelving of the ion to the $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}$ state with a wait time. Systematic errors, such as collisions with background gases, heating effects, impurity components, the shelving and pumping rates, and state detection, were carefully analyzed and estimated. We determined an improved value of the $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}$--state lifetime to be ${\ensuremath{\tau}}_{3/2}=1.195(8)$ s. Furthermore, the $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}\ensuremath{\rightarrow}4s\phantom{\rule{4pt}{0ex}}^{2}S_{1/2}$ quadrupole transition matrix element was measured to be ${S}_{ki}=7.936(26)e{a}_{0}^{2}$, and the ratio between the lifetimes of $3d{\phantom{\rule{4pt}{0ex}}}^{2}{D}_{3/2}$ and $3d{\phantom{\rule{4pt}{0ex}}}^{2}{D}_{5/2}$ was determined to be 1.018(11). Our method can be universally applied to lifetime measurements of other single ions and atoms with a similar structure.

Physical Review A•Oct 10, 2016•17 citations

Measurement of the lifetime of the 6p P21/2o level of Yb+

Steven Olmschenk, David Hayes, Dzmitry Matsukevich +4 more

We present a precise measurement of the lifetime of the $6p\text{ }{^{2}P}_{1/2}^{o}$ excited state of a single trapped ytterbium ion $({\text{Yb}}^{+})$. A time-correlated single-photon counting technique is used, where ultrafast pulses excite the ion and the emitted photons are coupled into a single-mode optical fiber. By performing the measurement on a single atom with fast excitation and excellent spatial filtering, we are able to eliminate common systematics. The lifetime of the $6p\text{ }{^{2}P}_{1/2}^{o}$ state is measured to be $8.12\ifmmode\pm\else\textpm\fi{}0.02\text{ }\text{ns}$, in good agreement with previous experimental measurements and some theoretical values.

arXiv:0906.0586•Physical Review A•Aug 10, 2009•56 citations

High-Resolution Spectroscopy of $^{173}$Yb$^{+}$ Ions

J. Jiang, A. V. Viatkina, Saaswath JK +7 more

Compared to other stable isotopes of $\rm{Yb}^+$, $^{173}\rm{Yb}^+$ has a richer hyperfine structure, which leads to more favorable clock transitions, spectroscopic techniques for probing new physics, and more sophisticated quantum computing architectures. However, to date, its electronic spectrum remains poorly characterized. Here, we report on efficient laser cooling, state preparation, and detection of a single trapped $^{173}\rm{Yb}^+$ ion. The previously unobserved $^2\!S_{1/2} \rightarrow {}^2\!D_{3/2}$ electric quadrupole transition at 436 nm is coherently excited, and the isotope shift between $^{171}\rm{Yb}^+$ and $^{173}\rm{Yb}^+$ on this transition is determined with an uncertainty of 1.4 Hz. Using microwave spectroscopy, we resolve the hyperfine structure (HFS) of the ${}^2\!D_{3/2}$ state with a relative uncertainty below $10^{-8}$. From the HFS measurement data, we infer for ${}^{173}$Yb a nuclear magnetic octupole moment $Ω= -0.062(8)\,({\rm b} \times μ_N)$ with uncertainty reduced by more than 2 orders of magnitude compared to previous studies. The data also allow us to determine hyperfine anomalies for the ${}^2\!S_{1/2}$ and ${}^2\!D_{3/2}$ states.

physics.atom-phCross-listedarXiv:2601.09585•Physical Review Letters•Jan 15, 2026•3 citations

171 Yb + 5 D 3/2 hyperfine state detection and F = 2 lifetime

M. Schacht, J R Danielson, S Rahaman +3 more

Abstract We report on measurements of the lifetime of the state in single ions confined in a radiofrequency quadrupole trap. Experimental parameters that affect hyperfine state preparation and detection efficiency are characterized and optimized. A set of wait times for optimal sampling of the lifetime is chosen and used to measure that lifetime with high statistical sensitivity. A systematic variation in this lifetime seems to be apparent. The source of the variation was not identified, but ion number and cooling rate appear to be ruled out. A net determination is made of ms which is significantly longer than other measurements of the same quantity with four times better statistical precision than the most recent measurement. An alternate shelving scheme is proposed that would provide S – D state discrimination for Yb + even isotopes as well as improved sensitivity for D state hyperfine discrimination in odd isotopes.

Journal of Physics B Atomic Molecular and Optical Physics•Mar 11, 2015•13 citations

Direct measurement of the 3 d 2 D 3 / 2 to 3 d 2 D 5 / 2 lifetime ratio in a single trapped 40 Ca +

H Shao, Yao Huang, H. Guan +1 more

Abstract We present for the first time a direct measurement of the lifetime ratio between the 3 d 2 D 3 / 2 and 3 d 2 D 5 / 2 metastable states in a single trapped 40 Ca + . A high-efficiency quantum state detection technique is adopted to monitor the quantum jumps, and a high precision and synchronized measurement sequence is used for laser control to study the rule of spontaneous decay. Our method shows that the lifetime ratio is a constant and is irrelevant to the dwell time; it is only determined by the spontaneous decay probabilities of the two metastable states at one random decay time, independent of the lifetimes of the two metastable states. Systematic errors such as collisions with background gases, heating effects, impurity components, the shelving and pumping rates and the photon counts are analyzed, and the lifetime ratio between the 3 d 2 D 3 / 2 and 3 d 2 D 5 / 2 states is directly measured to be 1.0257(43) with an uncertainty of 0.42%. Our result is in good agreement with the most precise many-body atomic structure calculations. Our method can be used to obtain the lifetime of a state which is usually difficult to measure and can be used to determine the magnetic dipole transition matrix elements in heavy ions such as Ba + and Ra + , and can also be universally applied to lifetime ratio measurements of other single atoms and ions with a similar structure.

Journal of Physics B Atomic Molecular and Optical Physics•Dec 13, 2017•4 citations
We present a method to precisely determine the 2D3/2^{2}D_{3/2}2D3/2​ state lifetime of a single trapped 174Yb+^{174}\mathrm{Yb}^{+}174Yb+ ion. This method is based on the detection of photons emitted from excited states, where a highly synchronized measurement sequence for laser control and an intensity-alternating sequence for atomic excitation and photon counting are used to minimize systematic errors. This method is easy to implement and is immune to fluctuations of magnetic field, laser intensity, and frequency detuning. Combined with the real-time approach of background photon correction, the radiative lifetime of the 2D3/2^{2}D_{3/2}2D3/2​ state is determined to be 54.83\ifmmode±\else\textpm\fi0.1854.83\ifmmode\pm\else\textpm\fi{}0.1854.83\ifmmode±\else\textpm\fi0.18 ms, which represents an order of magnitude improvement in measurement precision. The accurately determined lifetime sets a benchmark for many-body atomic theories and is particularly useful to determine the coherence time limit of the optical clock.
In the field of quantum metrology, transition matrix elements are crucial for accurately evaluating the black-body radiation shift of the clock transition and the amplitude of the related parity-violating transition, and can be used as probes to test quantum electrodynamic effects, especially at the 10−3–10−4 level. We developed a universal experimental approach to precisely determine the dipole transition matrix elements by using the shelving technique, for the species where two transition channels are involved, in which the excitation pulses with increasing duration were utilized to induce shelving, and the resulting shelving probabilities were determined by counting the scattered photons from the excited P1/22 state to the S1/22 ground state. Using the scattered photons offers several advantages, including insensitivity to fluctuations in magnetic field, laser intensity, and frequency detuning. An intensity-alternating sequence to minimize detection noise and a real-time approach for background photon correction were implemented in parallel. We applied this technique to a single Yb+ ion, and determined the 6p P1/22-5d D23/2 transition matrix element 2.9979(20) ea0, which indicates an order of magnitude improvement over existing reports. By combining our result with the 6p P1/22 lifetime of 8.12(2) ns, we extracted the 6s S1/22-6p P1/22 transition matrix element to be 2.4703(31) ea0. The accurately determined dipole transition matrix elements can serve as a benchmark for the development of high-precision atomic many-body theoretical methods.
We present a high-precision measurement of the 3d2D3/23d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}3d2D3/2​--state lifetime in a single trapped 40Ca+^{40}\mathrm{Ca}^{+}40Ca+. The measurement was performed using a high-efficiency quantum-state detection technique to monitor quantum jumps and a high-precision and highly synchronous measurement sequence for laser control. A feature in our measurement is the pumping rate of the 729-nm laser that was corrected in a real-time way. The 3d2D3/23d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}3d2D3/2​--state lifetime was obtained through the measurement of the spontaneous decay rate after incoherent shelving of the ion to the 3d2D3/23d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}3d2D3/2​ state with a wait time. Systematic errors, such as collisions with background gases, heating effects, impurity components, the shelving and pumping rates, and state detection, were carefully analyzed and estimated. We determined an improved value of the 3d2D3/23d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}3d2D3/2​--state lifetime to be ${\ensuremath{\tau}}_{3/2}=1.195(8)$ s. Furthermore, the $3d\phantom{\rule{4pt}{0ex}}^{2}D_{3/2}\ensuremath{\rightarrow}4s\phantom{\rule{4pt}{0ex}}^{2}S_{1/2}$ quadrupole transition matrix element was measured to be Ski=7.936(26)ea02{S}_{ki}=7.936(26)e{a}_{0}^{2}Ski​=7.936(26)ea02​, and the ratio between the lifetimes of 3d2D3/23d{\phantom{\rule{4pt}{0ex}}}^{2}{D}_{3/2}3d2D3/2​ and 3d2D5/23d{\phantom{\rule{4pt}{0ex}}}^{2}{D}_{5/2}3d2D5/2​ was determined to be 1.018(11). Our method can be universally applied to lifetime measurements of other single ions and atoms with a similar structure.
We present a precise measurement of the lifetime of the 6p 2P1/2o6p\text{ }{^{2}P}_{1/2}^{o}6p 2P1/2o​ excited state of a single trapped ytterbium ion (Yb+)({\text{Yb}}^{+})(Yb+). A time-correlated single-photon counting technique is used, where ultrafast pulses excite the ion and the emitted photons are coupled into a single-mode optical fiber. By performing the measurement on a single atom with fast excitation and excellent spatial filtering, we are able to eliminate common systematics. The lifetime of the 6p 2P1/2o6p\text{ }{^{2}P}_{1/2}^{o}6p 2P1/2o​ state is measured to be $8.12\ifmmode\pm\else\textpm\fi{}0.02\text{ }\text{ns}$, in good agreement with previous experimental measurements and some theoretical values.
High-Resolution Spectroscopy of 173^{173}173Yb+^{+}+ Ions
Compared to other stable isotopes of Yb+\rm{Yb}^+Yb+, 173Yb+^{173}\rm{Yb}^+173Yb+ has a richer hyperfine structure, which leads to more favorable clock transitions, spectroscopic techniques for probing new physics, and more sophisticated quantum computing architectures. However, to date, its electronic spectrum remains poorly characterized. Here, we report on efficient laser cooling, state preparation, and detection of a single trapped 173Yb+^{173}\rm{Yb}^+173Yb+ ion. The previously unobserved 2 ⁣S1/2→2 ⁣D3/2^2\!S_{1/2} \rightarrow {}^2\!D_{3/2}2S1/2​→2D3/2​ electric quadrupole transition at 436 nm is coherently excited, and the isotope shift between 171Yb+^{171}\rm{Yb}^+171Yb+ and 173Yb+^{173}\rm{Yb}^+173Yb+ on this transition is determined with an uncertainty of 1.4 Hz. Using microwave spectroscopy, we resolve the hyperfine structure (HFS) of the 2 ⁣D3/2{}^2\!D_{3/2}2D3/2​ state with a relative uncertainty below 10−810^{-8}10−8. From the HFS measurement data, we infer for 173{}^{173}173Yb a nuclear magnetic octupole moment Ω=−0.062(8) (b×μN)Ω= -0.062(8)\,({\rm b} \times μ_N)Ω=−0.062(8)(b×μN​) with uncertainty reduced by more than 2 orders of magnitude compared to previous studies. The data also allow us to determine hyperfine anomalies for the 2 ⁣S1/2{}^2\!S_{1/2}2S1/2​ and 2 ⁣D3/2{}^2\!D_{3/2}2D3/2​ states.
Abstract We report on measurements of the lifetime of the state in single ions confined in a radiofrequency quadrupole trap. Experimental parameters that affect hyperfine state preparation and detection efficiency are characterized and optimized. A set of wait times for optimal sampling of the lifetime is chosen and used to measure that lifetime with high statistical sensitivity. A systematic variation in this lifetime seems to be apparent. The source of the variation was not identified, but ion number and cooling rate appear to be ruled out. A net determination is made of ms which is significantly longer than other measurements of the same quantity with four times better statistical precision than the most recent measurement. An alternate shelving scheme is proposed that would provide S – D state discrimination for Yb + even isotopes as well as improved sensitivity for D state hyperfine discrimination in odd isotopes.
Abstract We present for the first time a direct measurement of the lifetime ratio between the 3 d 2 D 3 / 2 and 3 d 2 D 5 / 2 metastable states in a single trapped 40 Ca + . A high-efficiency quantum state detection technique is adopted to monitor the quantum jumps, and a high precision and synchronized measurement sequence is used for laser control to study the rule of spontaneous decay. Our method shows that the lifetime ratio is a constant and is irrelevant to the dwell time; it is only determined by the spontaneous decay probabilities of the two metastable states at one random decay time, independent of the lifetimes of the two metastable states. Systematic errors such as collisions with background gases, heating effects, impurity components, the shelving and pumping rates and the photon counts are analyzed, and the lifetime ratio between the 3 d 2 D 3 / 2 and 3 d 2 D 5 / 2 states is directly measured to be 1.0257(43) with an uncertainty of 0.42%. Our result is in good agreement with the most precise many-body atomic structure calculations. Our method can be used to obtain the lifetime of a state which is usually difficult to measure and can be used to determine the magnetic dipole transition matrix elements in heavy ions such as Ba + and Ra + , and can also be universally applied to lifetime ratio measurements of other single atoms and ions with a similar structure.