Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optoelectronics Instrumentation and Data Processing

Evaluation of the Operational Parameters of Single-Photon Detectors in Quantum Key Distribution Devices

Vladimir Zavodilenko, Anton Losev, Alexandr A. Filyaev, I. D. Pavlov

Published Feb 1, 2023• 0 citations
Publisher

Abstract

Abstract Automated measuring stand (AMS) for evaluation of the operational parameters of single-photon detectors (SPD) has been developed together with the software that implements the method of evaluating SPD efficiency parameters from the experimental data measured with AMS. We present graphical interface of the software, which allows generating recommendations for configuring operation mode of the detector and its subsequent integration into the quantum key distribution (QKD) system. Successful tests of the results of our work enable their implementation in the SPD production process.

DOI
10.3103/s8756699023010168

Related papers

Software for measuring parameters of single photon detectors at a modular research quantum key distribution setup

D. E. Kashirskiĭ, Meerimai Mazhitova

Abstract This article considers the issue of developing software for automated measurement of single photon detectors parameters at a modular research quantum key distribution setup. Using the developed software, a technique for measuring single photon detector parameters was tested. The dependences of the parameters on the pulse repetition rate, the degree of attenuation of laser radiation, and the duration of one measurement are analyzed.

Journal of Physics Conference Series•Dec 1, 2020•0 citations

Automation of Measuring Parameters of Single Photon Detectors at a Modular Research Quantum Key Distribution Setup

D. E. Kashirskiĭ, Meerimai Mazhitova

This paper considers the issue of developing software for automated measurement of single photon detectors at a modular research quantum key distribution setup. The results of measuring the parameters of single photon detectors are presented.

International Congress on Energy Fluxes and Radiation Effects (EFRE)•Sep 14, 2020•0 citations

Design and implementation of silicon single-photon avalanche photodiode modeling tool for QKD systems

Adil Fadhil Mushatet, Ahmed Ismael Khaleel, Shelan Khasro Tawfeeq

Single-photon detection concept is the most crucial factor that determines the performance of quantum key distribution (QKD) systems. In this paper, a simulator with time domain visualizers and configurable parameters using continuous time simulation approach is presented for modeling and investigating the performance of single-photon detectors operating in Gieger mode at the wavelength of 830 nm. The widely used C30921S silicon avalanche photodiode was modeled in terms of avalanche pulse, the effect of experiment conditions such as excess voltage, temperature and average photon number on the photon detection efficiency, dark count rate and afterpulse probability. This work shows a general repeatable modeling process for significant performance evaluation. The most remarkable result emerged from the simulated data generated and detected by commercial devices is that the modeling process provides guidance for single-photon detectors design and characterization. The validation and testing results of the single-photon avalanche detectors (SPAD) simulator showed acceptable results with the theoretical and experimental results reported in related references and the device's data sheets.

International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering•Jun 18, 2021•0 citations

Practical 15 Mb/s Quantum Key Distribution Using Compact Single-Photon Detectors

Tingting 婷婷 Shi 施, Zhengyu Yan, Yuanbin Fan +4 more

Abstract Quantum key distribution (QKD) is recognized as an unconditionally secure method of communication encryption, relying solely on the principles of quantum mechanics. A key performance metric for QKD systems is secure key rate (SKR), which is a critical factor for real-world applications. Herein, we report a practical QKD system, equipped with compact gated InGaAs/InP single-photon detectors (SPDs), that can generate a high SKR of 15.2 Mb/s with a channel loss of 2 dB. This exceptional performance stems from the ultra-low afterpulsing probability of the SPDs, which significantly reduces the bit error rate in the QKD system. The typical quantum bit error rate is 1.3%. The results validate the feasibility of an integrated, practical QKD system and offer a reliable solution for the future development of real-world QKD networks.

Chinese Physics Letters•Nov 1, 2025•1 citation

Key parameters of single photon receivers and sources for fi ber-optic quantum cryptography systems: parameter analysis and measurement methods

Stepan B. Bychkov, Ivan S. Korolev, С. В. Тихомиров

The development of fi ber-optic communication and data transmission systems gives rise to a number of new challenges, among which information protection against unauthorized access is of particular relevance. In response to this need, quantum cryptography has emerged – optical cryptographic systems with quantum key distribution. Such systems protect communication channels by encrypting data with a one-time secret key. The theoretical foundation guaranteeing secure key transmission relies on the Heisenberg uncertainty principle and the no-cloning theorem for quantum states of elementary particles. However, real-world quantum cryptography systems exhibit vulnerabilities stemming from imperfections in their components. Single photon detectors and single photon sources are critical elements of quantum key distribution systems. This work analyses the main types of attacks on quantum cryptography equipment and identifi es the key parameters of single photon sources and single photon detectors. Knowledge of their actual values can be crucial for proving a system’s resilience against attacks. Additionally, the paper describes the equipment and methods used to study single-photon sources. The study also describes the method and results of investigating the quantum effi ciency and false trigger probabilities of gated single-photon detectors with fi ber input. The described measurement methods are harmonized with the recommendations of the European Telecommunications Standards Institute. Together, the described measurement techniques and setups enable the assessment of single photon source and detector parameters during expert evaluation of quantum cryptography system vulnerabilities. The paper concludes with a call for the establishment of a reference database to support metrological assurance of key parameters for single photon sources and receivers, in order to advance quantum cryptography systems

Izmeritel`naya Tekhnika•May 11, 2026•0 citations

Measurement scheme and standardization progress of SPD component in commercial QKD system

Junsen Lai, Wenyu Zhao, Haiyi Zhang

Quantum key distribution (QKD) has advantage to provide information-theoretical security key sharing based on the fundamental laws of quantum physics. Single photon detectors (SPD) are crucial components of discrete variable (DV) QKD system, which influence the key generation rate, transmission distance, and even security of the system. For multivendor commercialized DV-QKD system, the characteristic and performance of SPDs are also the focus of measurement and standardization. In this paper, the single photon detection technology in QKD system is briefly reviewed, the measurement schemes of avalanche photodiode (APD) based SPD components in commercial DV-QKD system are proposed and analyzed, and the recent standardization progress of SPD component in China Communications Standards Association (CCSA) are discussed.

Eighth Symposium on Novel Photoelectronic Detection Technology and Applications•Mar 27, 2022•0 citations
Abstract Automated measuring stand (AMS) for evaluation of the operational parameters of single-photon detectors (SPD) has been developed together with the software that implements the method of evaluating SPD efficiency parameters from the experimental data measured with AMS. We present graphical interface of the software, which allows generating recommendations for configuring operation mode of the detector and its subsequent integration into the quantum key distribution (QKD) system. Successful tests of the results of our work enable their implementation in the SPD production process.
Single-photon detection concept is the most crucial factor that determines the performance of quantum key distribution (QKD) systems. In this paper, a simulator with time domain visualizers and configurable parameters using continuous time simulation approach is presented for modeling and investigating the performance of single-photon detectors operating in Gieger mode at the wavelength of 830 nm. The widely used C30921S silicon avalanche photodiode was modeled in terms of avalanche pulse, the effect of experiment conditions such as excess voltage, temperature and average photon number on the photon detection efficiency, dark count rate and afterpulse probability. This work shows a general repeatable modeling process for significant performance evaluation. The most remarkable result emerged from the simulated data generated and detected by commercial devices is that the modeling process provides guidance for single-photon detectors design and characterization. The validation and testing results of the single-photon avalanche detectors (SPAD) simulator showed acceptable results with the theoretical and experimental results reported in related references and the device's data sheets.
Abstract Quantum key distribution (QKD) is recognized as an unconditionally secure method of communication encryption, relying solely on the principles of quantum mechanics. A key performance metric for QKD systems is secure key rate (SKR), which is a critical factor for real-world applications. Herein, we report a practical QKD system, equipped with compact gated InGaAs/InP single-photon detectors (SPDs), that can generate a high SKR of 15.2 Mb/s with a channel loss of 2 dB. This exceptional performance stems from the ultra-low afterpulsing probability of the SPDs, which significantly reduces the bit error rate in the QKD system. The typical quantum bit error rate is 1.3%. The results validate the feasibility of an integrated, practical QKD system and offer a reliable solution for the future development of real-world QKD networks.
The development of fi ber-optic communication and data transmission systems gives rise to a number of new challenges, among which information protection against unauthorized access is of particular relevance. In response to this need, quantum cryptography has emerged – optical cryptographic systems with quantum key distribution. Such systems protect communication channels by encrypting data with a one-time secret key. The theoretical foundation guaranteeing secure key transmission relies on the Heisenberg uncertainty principle and the no-cloning theorem for quantum states of elementary particles. However, real-world quantum cryptography systems exhibit vulnerabilities stemming from imperfections in their components. Single photon detectors and single photon sources are critical elements of quantum key distribution systems. This work analyses the main types of attacks on quantum cryptography equipment and identifi es the key parameters of single photon sources and single photon detectors. Knowledge of their actual values can be crucial for proving a system’s resilience against attacks. Additionally, the paper describes the equipment and methods used to study single-photon sources. The study also describes the method and results of investigating the quantum effi ciency and false trigger probabilities of gated single-photon detectors with fi ber input. The described measurement methods are harmonized with the recommendations of the European Telecommunications Standards Institute. Together, the described measurement techniques and setups enable the assessment of single photon source and detector parameters during expert evaluation of quantum cryptography system vulnerabilities. The paper concludes with a call for the establishment of a reference database to support metrological assurance of key parameters for single photon sources and receivers, in order to advance quantum cryptography systems
Quantum key distribution (QKD) has advantage to provide information-theoretical security key sharing based on the fundamental laws of quantum physics. Single photon detectors (SPD) are crucial components of discrete variable (DV) QKD system, which influence the key generation rate, transmission distance, and even security of the system. For multivendor commercialized DV-QKD system, the characteristic and performance of SPDs are also the focus of measurement and standardization. In this paper, the single photon detection technology in QKD system is briefly reviewed, the measurement schemes of avalanche photodiode (APD) based SPD components in commercial DV-QKD system are proposed and analyzed, and the recent standardization progress of SPD component in China Communications Standards Association (CCSA) are discussed.