Measurement Science and Technology

In-situ measurement and close-loop control of atomic number density in an optically pumped magnetometer based on light absorption

Ziao Liu, Jixi Lu, Yeguang Yan, Di Zhan, Weiyi Wang, Xiaoyu Li, Jianli Li

Published May 4, 2023• 13 citations
Publisher

Abstract

Abstract For optically pumped atomic magnetometers, the attenuation of the pumping light through the alkali-metal vapor due to light absorption is related to the number density of alkali-metal atoms. In this study, we propose an in-situ measurement and control method of atomic number density based on light absorption in the temperature range of 60 °C–160 °C, which is a much wider temperature range than considered in previous reports. A light absorption-density model is proposed to accurately describe the relationship between the light transmittance and the atomic number density. The influence of static and oscillating magnetic fields on the atomic number density measurement is also analyzed. Based on this model, a close-loop system is constructed to control the atomic number density using an electric heater. The experimental results exhibit that the proposed method can limit the fluctuation of the atomic number density in the range of 1.4%.

DOI
10.1088/1361-6501/accdf6

Related papers

High-precision alkali-atom density measurement and control methods using light absorption for dual-beam SERF magnetometers

Ziao Liu, Jixi Lu, Zhaohui Hu +4 more

The alkali-atom density measurement method based on light absorption is highly suitable for a spin-exchange relaxationfree (SERF) atomic magnetometer because of its high-precision measurement and complete nonmagnetic interference.In this study, the optical rotation angle detection system based on polarization balance detection is utilized to realize the alkali-atom density real-time measurement without affecting magnetic field measurement.We discovered that there exists an optimal frequency detuning of the probe light, which offers the highest sensitivity in alkali-atom density measurement and the lowest susceptibility to temperature fluctuations in terms of the scale factor.In contrast to conventional light absorption measurements based on pump light, this method demonstrated a threefold improvement in alkali-atom density measurement sensitivity while remaining immune to ambient magnetic fields and incident light intensity fluctuations.Furthermore, we utilized this method to achieve closed-loop temperature control with an accuracy of 0.04°C.

Chinese Optics Letters•Jan 1, 2024•9 citations

In situ determination of alkali metal density using phase-frequency analysis on atomic magnetometers

Han Yao, Hong Zhang, Danyue Ma +2 more

Abstract The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.

Measurement Science and Technology•Jul 6, 2018•8 citations

Alkali Atomic Density Detection With Arbitrarily Polarized Light

Xuejing Liu, Menglu Wang, Yuhan Li +3 more

The atomic density of an alkali vapor cell is a critical factor in determining the performance of atomic magnetometers. This paper presents a novel method to detect the density of an alkali atomic ensemble under arbitrary polarization states. By establishing a comprehensive model that correlates the absorption spectrum with the incident light’s polarization, our approach enables real-time and flexible measurements across varying temperatures and polarization angles. Experimental validations are conducted by systematically rotating a quarter-wave plate and controlling the vapor cell temperature, thereby collecting transmission spectra at multiple polarizations. The results demonstrate that the proposed method simplifies density measurements while preserving high accuracy, laying a solid foundation for further research on Spin-Exchange Relaxation-Free (SERF) atomic magnetometers. This technique serves as a versatile and effective tool for in-situ monitoring of alkali metal vapor density in various sensor applications.

IEEE Sensors Journal•Apr 7, 2025•1 citation

Suppression of Light Shift for High-Density Alkali-Metal Atomic Magnetometer

Jixi Lu, Wei Quan, Ming Ding +2 more

The light shift is an important error source for atomic magnetometers. It would vanish if the frequency of the circularly polarized light is tuned to the optical resonance center. For high-density alkali-metal atomic magnetometers, the vapor cell has a large optical depth near the resonance, resulting in the difficulty in obtaining the exact resonance center by measuring the optical absorption line. In order to solve this problem, we propose a method to tune the pump light to a frequency where the shift is minimum based on the magnetic field zeroing technique. In addition, we also compare our results with the fitting center of the optical absorption line based on the measurement data far detuned from the resonance. The experimental results show that our method achieves a better suppression result of the light shift.

IEEE Sensors Journal•Oct 24, 2018•42 citations

The Space Density Distribution of Alkali Metal Atoms in a SERF Atomic Magnetometer

Qiang Guo, Xuewen Li, Ning Zhang +4 more

The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.

IEEE Sensors Journal•Jan 27, 2022•13 citations

Optimization of the alkali-metal density ratio in a hybrid optical pumping atomic magnetometer

Yang Li, Xue-Jing Liu, Hongwei Cai +2 more

Abstract The alkali-metal density ratio is one of the primary design parameters in hybrid optical pumping magnetometers. Here, experiments were conducted with a hybrid optically-pumped atomic magnetometer using a cell containing potassium and rubidium. Potassium atoms are pumped by a laser and become polarized. Rubidium atoms are polarized via collisions with potassium atoms and can be probed. The light shift was eliminated by adjusting the density ratio of potassium to rubidium atoms and by optimizing the pump laser parameters. The effect of fluctuations in the laser power and frequency were minimized as a result. The optimal density ratio and magnetic field sensitivity were 1:277 and 0.68 fT Hz −1/2 , respectively.

Measurement Science and Technology•Nov 9, 2018•18 citations
Abstract For optically pumped atomic magnetometers, the attenuation of the pumping light through the alkali-metal vapor due to light absorption is related to the number density of alkali-metal atoms. In this study, we propose an in-situ measurement and control method of atomic number density based on light absorption in the temperature range of 60 °C–160 °C, which is a much wider temperature range than considered in previous reports. A light absorption-density model is proposed to accurately describe the relationship between the light transmittance and the atomic number density. The influence of static and oscillating magnetic fields on the atomic number density measurement is also analyzed. Based on this model, a close-loop system is constructed to control the atomic number density using an electric heater. The experimental results exhibit that the proposed method can limit the fluctuation of the atomic number density in the range of 1.4%.
The alkali-atom density measurement method based on light absorption is highly suitable for a spin-exchange relaxationfree (SERF) atomic magnetometer because of its high-precision measurement and complete nonmagnetic interference.In this study, the optical rotation angle detection system based on polarization balance detection is utilized to realize the alkali-atom density real-time measurement without affecting magnetic field measurement.We discovered that there exists an optimal frequency detuning of the probe light, which offers the highest sensitivity in alkali-atom density measurement and the lowest susceptibility to temperature fluctuations in terms of the scale factor.In contrast to conventional light absorption measurements based on pump light, this method demonstrated a threefold improvement in alkali-atom density measurement sensitivity while remaining immune to ambient magnetic fields and incident light intensity fluctuations.Furthermore, we utilized this method to achieve closed-loop temperature control with an accuracy of 0.04°C.
Abstract The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.
The atomic density of an alkali vapor cell is a critical factor in determining the performance of atomic magnetometers. This paper presents a novel method to detect the density of an alkali atomic ensemble under arbitrary polarization states. By establishing a comprehensive model that correlates the absorption spectrum with the incident light’s polarization, our approach enables real-time and flexible measurements across varying temperatures and polarization angles. Experimental validations are conducted by systematically rotating a quarter-wave plate and controlling the vapor cell temperature, thereby collecting transmission spectra at multiple polarizations. The results demonstrate that the proposed method simplifies density measurements while preserving high accuracy, laying a solid foundation for further research on Spin-Exchange Relaxation-Free (SERF) atomic magnetometers. This technique serves as a versatile and effective tool for in-situ monitoring of alkali metal vapor density in various sensor applications.
The light shift is an important error source for atomic magnetometers. It would vanish if the frequency of the circularly polarized light is tuned to the optical resonance center. For high-density alkali-metal atomic magnetometers, the vapor cell has a large optical depth near the resonance, resulting in the difficulty in obtaining the exact resonance center by measuring the optical absorption line. In order to solve this problem, we propose a method to tune the pump light to a frequency where the shift is minimum based on the magnetic field zeroing technique. In addition, we also compare our results with the fitting center of the optical absorption line based on the measurement data far detuned from the resonance. The experimental results show that our method achieves a better suppression result of the light shift.
The number density of alkali atoms in vaper cell is an important parameter for atomic magnetometer. The vapor cell is usually heated to a high temperature for the number density exceed to 1018m−3to achieve the spin-exchange-relaxation-free (SERF) process. The optical rotation of multichannel atomic magnetometers is affected by the number density distribution. We present an effective method for monitoring and analyzing the spatial distribution homogeneity of the atomic number density in the alkali metal cell within the SERF magnetometer. The numerical results from researching the model of electric heating films and ovens show that the temperature gradient increases with an increase in the cell temperature. This causes an nonuniform number density distribution based on the saturated vapor pressure curve. We present a laser absorption spectroscopy method by using the high-resolution beam profiling camera to record the power of the beam before and after the cell. An optimized optical system of the atomic magnetometer has been established by measuring the the number density variation in the spatial distribution in mm scale. The number density variation coefficient, which is introduced to evaluate the distribution homogeneity, increases from 0.0257 to 0.0333 when the temperature of the oven wall rises from 140°C to 190 °C, showing the same trend as the simulation results. The optical rotation distribution is calculated according to the magnetometer output signal formula. This study is of great interest for optimizing the oven structure and improving the stability of atomic spin polarization and sensitivity of the multichannel magnetometer.
Abstract The alkali-metal density ratio is one of the primary design parameters in hybrid optical pumping magnetometers. Here, experiments were conducted with a hybrid optically-pumped atomic magnetometer using a cell containing potassium and rubidium. Potassium atoms are pumped by a laser and become polarized. Rubidium atoms are polarized via collisions with potassium atoms and can be probed. The light shift was eliminated by adjusting the density ratio of potassium to rubidium atoms and by optimizing the pump laser parameters. The effect of fluctuations in the laser power and frequency were minimized as a result. The optimal density ratio and magnetic field sensitivity were 1:277 and 0.68 fT Hz −1/2 , respectively.