Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advanced Science

Population Control of Upconversion Energy Transfer for Stimulation Emission Depletion Nanoscopy

Yongtao Liu, Shihui Wen, Fan Wang, Chao Zuo, Chaohao Chen, Jiajia Zhou, Dayong Jin

Published Apr 23, 2023• 23 citations
Publisher

Abstract

Abstract Upconverting stimulated emission depletion microscopy (U‐STED) is emerging as an effective approach for super‐resolution imaging due to its significantly low depletion power and its ability to surpass the limitations of the square‐root law and achieve higher resolution. Though the compelling performance, a trade‐off between the spatial resolution and imaging quality in U‐STED has been recognized in restricting the usability due to the low excitation power drove high depletion efficiency. Moreover, it is a burden to search for the right power relying on trial and error as the underpinning mechanism is unknown. Here, a method is proposed that can easily predict the ideal excitation power for high depletion efficiency with the assistance of the non‐saturate excitation based on the dynamic cross‐relaxation (CR) energy transfer of upconversion nanoparticles. This allows the authors to employ the rate equation model to simulate the populations of each relevant energy state of lanthanides and predict the ideal excitation power for high depletion efficiency. The authors demonstrate that the resolution of STED with the assistance of nonsaturated confocal super‐resolution results can easily achieve the highest resolution of sub‐40 nm, 1/24th of the excitation wavelengths. The finding on the CR effect provides opportunities for population control in realizing low‐power high‐resolution nanoscopy.

DOI
10.1002/advs.202205990

Related papers

Super-resolution microscopy enabled by high-efficiency surface-migration emission depletion

Rui Pu, Qiuqiang Zhan, Xingyun Peng +6 more

Abstract Nonlinear depletion of fluorescence states by stimulated emission constitutes the basis of stimulated emission depletion (STED) microscopy. Despite significant efforts over the past decade, achieving super-resolution at low saturation intensities by STED remains a major technical challenge. By harnessing the surface quenching effect in NaGdF 4 :Yb/Tm nanocrystals, we report here high-efficiency emission depletion through surface migration. Using a dual-beam, continuous-wave laser manipulation scheme (975-nm excitation and 730-nm de-excitation), we achieved an emission depletion efficiency of over 95% and a low saturation intensity of 18.3 kW cm −2 . Emission depletion by surface migration through gadolinium sublattices enables super-resolution imaging with sub-20 nm lateral resolution. Our approach circumvents the fundamental limitation of high-intensity STED microscopy, providing autofluorescence-free, re-excitation-background-free imaging with a saturation intensity over three orders of magnitude lower than conventional fluorophores. We also demonstrated super-resolution imaging of actin filaments in Hela cells labeled with 8-nm nanoparticles. Combined with the highly photostable lanthanide luminescence, surface-migration emission depletion (SMED) could provide a powerful mechanism for low-power, super-resolution imaging or biological tracking as well as super-resolved optical sensing/writing and lithography.

Nature Communications•Nov 4, 2022•52 citations

STED with wavelengths closer to the emission maximum

Giuseppe Vicidomini, Gaël Moneron, Christian Eggeling +2 more

In stimulated emission depletion (STED) nanoscopy the wavelength of the STED beam is usually tuned towards the red tail of the emission maximum of the fluorophore. Shifting the STED wavelength closer to the emission peak, i.e. towards the blue region, favorably increases the stimulated emission cross-section. However, this blue-shifting also increases the probability to excite fluorophores that have remained in their ground state, compromising the image contrast. Here we present a method to exploit the higher STED efficiency of blue-shifted STED beams while maintaining the contrast in the image. The method is exemplified by imaging immunolabeled features in mammalian cells with an up to 3-fold increased STED efficiency compared to that encountered in standard STED nanoscopy implementations.

Optics Express•Feb 16, 2012•104 citations

Stimulated Emission Depletion Microscopy Resolves Individual Nitrogen Vacancy Centers in Diamond Nanocrystals

Silvia Arroyo-Camejo, Marie‐Pierre Adam, Mondher Besbes +6 more

Nitrogen-vacancy (NV) color centers in nanodiamonds are highly promising for bioimaging and sensing. However, resolving individual NV centers within nanodiamond particles and the controlled addressing and readout of their spin state has remained a major challenge. Spatially stochastic super-resolution techniques cannot provide this capability in principle, whereas coordinate-controlled super-resolution imaging methods, like stimulated emission depletion (STED) microscopy, have been predicted to fail in nanodiamonds. Here we show that, contrary to these predictions, STED can resolve single NV centers in 40-250 nm sized nanodiamonds with a resolution of ≈10 nm. Even multiple adjacent NVs located in single nanodiamonds can be imaged individually down to relative distances of ≈15 nm. Far-field optical super-resolution of NVs inside nanodiamonds is highly relevant for bioimaging applications of these fluorescent nanolabels. The targeted addressing and readout of individual NV(-) spins inside nanodiamonds by STED should also be of high significance for quantum sensing and information applications.

ACS Nano•Nov 18, 2013•135 citations

An indirectly stimulated emission depletion method for STED microscopy

Zhijun Luo, Yanan Liu, Menglin Chen +2 more

Abstract In stimulated emission depletion (STED) microscopy, the resolution can be improved by directly depleting electrons from the target excitation state to the ground state at the doughnut area. In the study, an indirectly STED method for STED microscopy was proposed. A dynamic model based on state transition process for STED microscopy with triexciton fluorescence quantum dots was firstly developed. The depletion efficiencies of both direct and indirect ways were then theoretically investigated. Compared with direct depletion of quantum dots from their triexciton state to the ground state, indirect depletion of quantum dots from their biexciton state to the ground state was more efficient for triexciton depletion. This indirect depletion method offers a new route to reduce the depletion laser intensity for STED microscopy in order to achieve a nanometer imaging resolution.

Journal of Physics D Applied Physics•Jul 15, 2019•0 citations

Photobleaching in STED nanoscopy and its dependence on the photon flux applied for reversible silencing of the fluorophore

Joanna Oracz, Volker Westphal, Czesław Radzewicz +2 more

In STED (stimulated emission depletion) nanoscopy, the resolution and signal are limited by the fluorophore de-excitation efficiency and photobleaching. Here, we investigated their dependence on the pulse duration and power of the applied STED light for the popular 750 nm wavelength. In experiments with red- and orange-emitting dyes, the pulse duration was varied from the sub-picosecond range up to continuous-wave conditions, with average powers up to 200 mW at 80 MHz repetition rate, i.e. peak powers up to 1 kW and pulse energies up to 2.5 nJ. We demonstrate the dependence of bleaching on pulse duration, which dictates the optimal parameters of how to deliver the photons required for transient fluorophore silencing. Measurements with the dye ATTO647N reveal that the bleaching of excited molecules scales with peak power with a single effective order ~1.4. This motivates peak power reduction while maintaining the number of STED-light photons, in line with the superior resolution commonly achieved for nanosecond STED pulses. Other dyes (ATTO590, STAR580, STAR635P) exhibit two distinctive bleaching regimes for constant pulse energy, one with strong dependence on peak power, one nearly independent. We interpret the results within a photobleaching model that guides quantitative predictions of resolution and bleaching.

Scientific Reports•Sep 6, 2017•77 citations

Stimulated Emission Depletion Microscopy with Diamond Silicon Vacancy Centers

Yaser Silani, Forrest Hubert, Víctor M. Acosta

The spatial resolution and fluorescence signal amplitude in stimulated emission depletion (STED) microscopy is limited by the photostability of available fluorophores. Here, we show that negatively charged silicon vacancy (SiV) centers in diamond are promising fluorophores for STED microscopy, owing to their photostable, near-infrared emission and favorable photophysical properties. A home-built pulsed STED microscope was used to image shallow implanted SiV centers in bulk diamond at room temperature. The SiV stimulated emission cross section for 765–800 nm light is found to be (4.0 ± 0.3) × 10 –17 cm 2, which is approximately 2–4 times larger than that of the negatively charged diamond nitrogen vacancy center and approaches that of commonly used organic dye molecules. We performed STED microscopy on isolated SiV centers and observed a lateral full-width-at-half-maximum spot size of 89 ± 2 nm, limited by the low available STED laser pulse energy (0.4 nJ). For a pulse energy of 5 nJ, the resolution is expected to be ∼20 nm. We show that the present microscope can resolve SiV centers separated by ≲150 nm that cannot be resolved by confocal microscopy.

arXiv:1907.08604•ACS Photonics•Sep 9, 2019•17 citations
Abstract Upconverting stimulated emission depletion microscopy (U‐STED) is emerging as an effective approach for super‐resolution imaging due to its significantly low depletion power and its ability to surpass the limitations of the square‐root law and achieve higher resolution. Though the compelling performance, a trade‐off between the spatial resolution and imaging quality in U‐STED has been recognized in restricting the usability due to the low excitation power drove high depletion efficiency. Moreover, it is a burden to search for the right power relying on trial and error as the underpinning mechanism is unknown. Here, a method is proposed that can easily predict the ideal excitation power for high depletion efficiency with the assistance of the non‐saturate excitation based on the dynamic cross‐relaxation (CR) energy transfer of upconversion nanoparticles. This allows the authors to employ the rate equation model to simulate the populations of each relevant energy state of lanthanides and predict the ideal excitation power for high depletion efficiency. The authors demonstrate that the resolution of STED with the assistance of nonsaturated confocal super‐resolution results can easily achieve the highest resolution of sub‐40 nm, 1/24th of the excitation wavelengths. The finding on the CR effect provides opportunities for population control in realizing low‐power high‐resolution nanoscopy.
Abstract Nonlinear depletion of fluorescence states by stimulated emission constitutes the basis of stimulated emission depletion (STED) microscopy. Despite significant efforts over the past decade, achieving super-resolution at low saturation intensities by STED remains a major technical challenge. By harnessing the surface quenching effect in NaGdF 4 :Yb/Tm nanocrystals, we report here high-efficiency emission depletion through surface migration. Using a dual-beam, continuous-wave laser manipulation scheme (975-nm excitation and 730-nm de-excitation), we achieved an emission depletion efficiency of over 95% and a low saturation intensity of 18.3 kW cm −2 . Emission depletion by surface migration through gadolinium sublattices enables super-resolution imaging with sub-20 nm lateral resolution. Our approach circumvents the fundamental limitation of high-intensity STED microscopy, providing autofluorescence-free, re-excitation-background-free imaging with a saturation intensity over three orders of magnitude lower than conventional fluorophores. We also demonstrated super-resolution imaging of actin filaments in Hela cells labeled with 8-nm nanoparticles. Combined with the highly photostable lanthanide luminescence, surface-migration emission depletion (SMED) could provide a powerful mechanism for low-power, super-resolution imaging or biological tracking as well as super-resolved optical sensing/writing and lithography.
In stimulated emission depletion (STED) nanoscopy the wavelength of the STED beam is usually tuned towards the red tail of the emission maximum of the fluorophore. Shifting the STED wavelength closer to the emission peak, i.e. towards the blue region, favorably increases the stimulated emission cross-section. However, this blue-shifting also increases the probability to excite fluorophores that have remained in their ground state, compromising the image contrast. Here we present a method to exploit the higher STED efficiency of blue-shifted STED beams while maintaining the contrast in the image. The method is exemplified by imaging immunolabeled features in mammalian cells with an up to 3-fold increased STED efficiency compared to that encountered in standard STED nanoscopy implementations.
Nitrogen-vacancy (NV) color centers in nanodiamonds are highly promising for bioimaging and sensing. However, resolving individual NV centers within nanodiamond particles and the controlled addressing and readout of their spin state has remained a major challenge. Spatially stochastic super-resolution techniques cannot provide this capability in principle, whereas coordinate-controlled super-resolution imaging methods, like stimulated emission depletion (STED) microscopy, have been predicted to fail in nanodiamonds. Here we show that, contrary to these predictions, STED can resolve single NV centers in 40-250 nm sized nanodiamonds with a resolution of ≈10 nm. Even multiple adjacent NVs located in single nanodiamonds can be imaged individually down to relative distances of ≈15 nm. Far-field optical super-resolution of NVs inside nanodiamonds is highly relevant for bioimaging applications of these fluorescent nanolabels. The targeted addressing and readout of individual NV(-) spins inside nanodiamonds by STED should also be of high significance for quantum sensing and information applications.
Abstract In stimulated emission depletion (STED) microscopy, the resolution can be improved by directly depleting electrons from the target excitation state to the ground state at the doughnut area. In the study, an indirectly STED method for STED microscopy was proposed. A dynamic model based on state transition process for STED microscopy with triexciton fluorescence quantum dots was firstly developed. The depletion efficiencies of both direct and indirect ways were then theoretically investigated. Compared with direct depletion of quantum dots from their triexciton state to the ground state, indirect depletion of quantum dots from their biexciton state to the ground state was more efficient for triexciton depletion. This indirect depletion method offers a new route to reduce the depletion laser intensity for STED microscopy in order to achieve a nanometer imaging resolution.
In STED (stimulated emission depletion) nanoscopy, the resolution and signal are limited by the fluorophore de-excitation efficiency and photobleaching. Here, we investigated their dependence on the pulse duration and power of the applied STED light for the popular 750 nm wavelength. In experiments with red- and orange-emitting dyes, the pulse duration was varied from the sub-picosecond range up to continuous-wave conditions, with average powers up to 200 mW at 80 MHz repetition rate, i.e. peak powers up to 1 kW and pulse energies up to 2.5 nJ. We demonstrate the dependence of bleaching on pulse duration, which dictates the optimal parameters of how to deliver the photons required for transient fluorophore silencing. Measurements with the dye ATTO647N reveal that the bleaching of excited molecules scales with peak power with a single effective order ~1.4. This motivates peak power reduction while maintaining the number of STED-light photons, in line with the superior resolution commonly achieved for nanosecond STED pulses. Other dyes (ATTO590, STAR580, STAR635P) exhibit two distinctive bleaching regimes for constant pulse energy, one with strong dependence on peak power, one nearly independent. We interpret the results within a photobleaching model that guides quantitative predictions of resolution and bleaching.
The spatial resolution and fluorescence signal amplitude in stimulated emission depletion (STED) microscopy is limited by the photostability of available fluorophores. Here, we show that negatively charged silicon vacancy (SiV) centers in diamond are promising fluorophores for STED microscopy, owing to their photostable, near-infrared emission and favorable photophysical properties. A home-built pulsed STED microscope was used to image shallow implanted SiV centers in bulk diamond at room temperature. The SiV stimulated emission cross section for 765–800 nm light is found to be (4.0 ± 0.3) × 10 –17 cm 2, which is approximately 2–4 times larger than that of the negatively charged diamond nitrogen vacancy center and approaches that of commonly used organic dye molecules. We performed STED microscopy on isolated SiV centers and observed a lateral full-width-at-half-maximum spot size of 89 ± 2 nm, limited by the low available STED laser pulse energy (0.4 nJ). For a pulse energy of 5 nJ, the resolution is expected to be ∼20 nm. We show that the present microscope can resolve SiV centers separated by ≲150 nm that cannot be resolved by confocal microscopy.