Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Micromachines

Microwave Passive Direction-Finding Method Based on NV Color Center in Diamond

Qi Wang, Yusong Liu, Yue Ning Qin, Hao Guo, Jun Tang

Published Mar 30, 2023• 2 citations
Publisher

Abstract

In this study, we established a passive direction-finding scheme based on microwave power measurement: Microwave intensity was detected using microwave-frequency proportion integration differentiation control and coherent population oscillation effect converting the change in microwave resonance peak intensity into a shift of the microwave frequency spectrum, for which the minimum microwave intensity resolution was -20 dBm. The direction angle of the microwave source was calculated using the weighted global least squares method of microwave field distribution. This lay in the 12~26 dBm microwave emission intensity range, and the measurement position was in the range of (-15°~15°). The average angle error of the angle measurement was 0.24°, and the maximum angle error was 0.48°. In this study, we established a microwave passive direction-finding scheme based on quantum precision sensing, which measures the microwave frequency, intensity, and angle in a small space and has a simple system structure, small equipment size, and low system power consumption. In this study, we provide a basis for the future application of quantum sensors in microwave direction measurements.

DOI
10.3390/mi14040774

Related papers

Microwave target location method based on the diamond NV color center

Yusong Liu, Qi Wang, Yue Qin +7 more

We propose a method for microwave target source localization based on the diamond nitrogen vacancy color center. We use coherent population oscillation effect and modulation and demodulation techniques to achieve the detection of microwave intensity of microwave target sources, with a minimum detection intensity of 0.59 µW. Positioning of the microwave source was achieved within 50×100cm 2 distance from the system 1 m away using the cubic spline interpolation algorithm and minimum mean squared error. The maximum positioning error was 3.5 cm. This method provides a new, to the best of our knowledge, idea for the passive localization of microwave targets.

Applied Optics•May 5, 2023•3 citations

Research on DC Current Measurement Method based on Solid-state Quantum

Mingyang Liu, Changkui Wang, Xiaofei Li +2 more

The research focuses on the solid-state spin system of diamond NV (Negatively Charged Nitrogen Vacancy, NV) color centers, which exhibit excellent optical readout, polarization properties, and millisecond-scale coherent time. This makes it an important means to achieve quantum information processing and quantum precision measurement. Additionally, its ultrahigh sensitivity to magnetic fields provides a potential path for diamond’s high-precision current measurement. This paper investigates a reliable method in the field of direct current measurement using quantum sensing technology based on diamond NV color centers. It involves measuring the change in the optically detected magnetic resonance spectrum based on a fixed microwave frequency to achieve magnetic field measurement. Simultaneously, by utilizing the spatial distribution of magnetic sensor heads, it achieves current inversion. Finally, an experimental platform was constructed for validation. Preliminary results indicate that the linear fit error for direct current amplitude is less than 10^-7, confirming the feasibility of this technological approach and providing a potential application for diamond in measuring currents in power systems.

IEEE International Conference on Internet of Things (iThings) and IEEE Green Computing and Communications (GreenCom) and IEEE Cyber, Physical and Social Computing (CPSCom) and IEEE Smart Data (SmartData)•Dec 17, 2023•1 citation

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•1 citation

High-Dynamic-Range Detection of Microwave Signal on Chip Surface Based on Diamond Sensors

Ding Wang, Huan Fei Wen, Xin Li +9 more

This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1$\mu$W. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.

IEEE Transactions on Microwave Theory and Techniques•Nov 3, 2023•10 citations

Simultaneous Determination of Multiple Microwave Signals With High-Frequency Resolution Using Quantum Sensing Technique

Rui Zhao, Ding Wang, Huan Fei Wen +4 more

This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•2 citations

Microwave Angle-of-Arrival Detection using Nitrogen-Vacancy Center Receiver

Hao Zhang, Zhonghao Li, Bokun Duan +5 more

Angle of Arrival (AoA) detection plays a pivotal role in wireless communication, target localization, and remote sensing navigation, demonstrating significant importance and extensive application potential. This study introduces a microwave AoA measurement method based on a solid-state quantum spin nitrogen-vacancy (NV) center receiver, which has tunable microwave frequency response. By integrating microwave heterodyne detection with an electron spin model, the proposed approach achieves high-precision microwave phase measurement. Exploiting the functional relationship between phase and incident angle, accurate AoA sensing is realized. Furthermore, leveraging the magnetic field-tuned resonance characteristics of NV centers, a microwave AoA measurement system capable of accommo-dating diverse detection frequency bands is constructed. Experimental validation at multiple operating frequencies confirms the system’s frequency reconfigurability, stability, and reliability. Results indicate that within the tested range of 40° to 140°, the AoA measurements exhibit the smallest deviation of 0.62° at an incident angle of 90°, while the largest deviation of 4.58° is observed at an incident angle of 140°. Long-term heterodyne measurements further verify the phase stability of the proposed detection scheme. These findings provide crucial experimental evidence for the application of quantum technology in electromagnetic target identification, navigation, and localization, while laying a robust foundation for the development of miniaturized and integrated AoA quantum measurement systems.

IEEE Transactions on Antennas and Propagation•Jan 1, 2026•0 citations
In this study, we established a passive direction-finding scheme based on microwave power measurement: Microwave intensity was detected using microwave-frequency proportion integration differentiation control and coherent population oscillation effect converting the change in microwave resonance peak intensity into a shift of the microwave frequency spectrum, for which the minimum microwave intensity resolution was -20 dBm. The direction angle of the microwave source was calculated using the weighted global least squares method of microwave field distribution. This lay in the 12~26 dBm microwave emission intensity range, and the measurement position was in the range of (-15°~15°). The average angle error of the angle measurement was 0.24°, and the maximum angle error was 0.48°. In this study, we established a microwave passive direction-finding scheme based on quantum precision sensing, which measures the microwave frequency, intensity, and angle in a small space and has a simple system structure, small equipment size, and low system power consumption. In this study, we provide a basis for the future application of quantum sensors in microwave direction measurements.
We propose a method for microwave target source localization based on the diamond nitrogen vacancy color center. We use coherent population oscillation effect and modulation and demodulation techniques to achieve the detection of microwave intensity of microwave target sources, with a minimum detection intensity of 0.59 µW. Positioning of the microwave source was achieved within 50×100cm 2 distance from the system 1 m away using the cubic spline interpolation algorithm and minimum mean squared error. The maximum positioning error was 3.5 cm. This method provides a new, to the best of our knowledge, idea for the passive localization of microwave targets.
The research focuses on the solid-state spin system of diamond NV (Negatively Charged Nitrogen Vacancy, NV) color centers, which exhibit excellent optical readout, polarization properties, and millisecond-scale coherent time. This makes it an important means to achieve quantum information processing and quantum precision measurement. Additionally, its ultrahigh sensitivity to magnetic fields provides a potential path for diamond’s high-precision current measurement. This paper investigates a reliable method in the field of direct current measurement using quantum sensing technology based on diamond NV color centers. It involves measuring the change in the optically detected magnetic resonance spectrum based on a fixed microwave frequency to achieve magnetic field measurement. Simultaneously, by utilizing the spatial distribution of magnetic sensor heads, it achieves current inversion. Finally, an experimental platform was constructed for validation. Preliminary results indicate that the linear fit error for direct current amplitude is less than 10^-7, confirming the feasibility of this technological approach and providing a potential application for diamond in measuring currents in power systems.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
This article proposed a microwave (MW) detection method by utilizing the effect of the dual MW on nitrogen-vacancy (NV) centers in diamond. We established a theoretical model of dual MW superposition and experimentally discovered the unusual peak in the optically detected magnetic resonance (ODMR) spectrum. The peak frequency and the full-width at half-maximum of the unusual peak, as well as fluorescence intensity in the nonresonant frequency range of the ODMR spectrum, were systematically analyzed to obtain the frequency and amplitude of the measured MW signals. The broadband MW detection was realized in a wide range of 2240–4512 MHz by utilizing the linear relation between the magnetic field and the resonant frequency in the Zeeman splitting. The experiments showed that the minimum detection power was up to 1μ\muμW. The proposed approach can greatly improve the practicability of detecting MW fields on chip surfaces by quantum engineering techniques.
This article presents a method to simultaneously determine multiple microwave signals using the hole-burning effect based on nitrogen-vacancy (NV) centers in diamonds. Tracking the anomalous peaks caused by fixed-frequency microwave signals in the optically detected magnetic resonance spectrum, the frequencies under test can be detected with high precision and accuracy in real time. Meanwhile, the applicability of the scheme in detecting microwave signals of different power is evaluated systematically by adjusting the power of measured fixed-frequency microwave signals. In addition, the frequency resolution of the system is characterized by modulating the frequency of one of the microwave signals. The experiment results indicate that the frequency resolution is as small as 5 kHz and the recognition deviation is less than 0.40 kHz. The method will provide a new idea in the field of electromagnetic compatibility testing, radio signal processing, and Internet of Things Engineering.
Angle of Arrival (AoA) detection plays a pivotal role in wireless communication, target localization, and remote sensing navigation, demonstrating significant importance and extensive application potential. This study introduces a microwave AoA measurement method based on a solid-state quantum spin nitrogen-vacancy (NV) center receiver, which has tunable microwave frequency response. By integrating microwave heterodyne detection with an electron spin model, the proposed approach achieves high-precision microwave phase measurement. Exploiting the functional relationship between phase and incident angle, accurate AoA sensing is realized. Furthermore, leveraging the magnetic field-tuned resonance characteristics of NV centers, a microwave AoA measurement system capable of accommo-dating diverse detection frequency bands is constructed. Experimental validation at multiple operating frequencies confirms the system’s frequency reconfigurability, stability, and reliability. Results indicate that within the tested range of 40° to 140°, the AoA measurements exhibit the smallest deviation of 0.62° at an incident angle of 90°, while the largest deviation of 4.58° is observed at an incident angle of 140°. Long-term heterodyne measurements further verify the phase stability of the proposed detection scheme. These findings provide crucial experimental evidence for the application of quantum technology in electromagnetic target identification, navigation, and localization, while laying a robust foundation for the development of miniaturized and integrated AoA quantum measurement systems.