Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Dual-Species All-Optical Magnetometer Based on a Cs-K Hybrid Vapor Cell

Yudong Ding, Wei Xiao, Yixin Zhao, Teng Wu, Xiang Peng, Hong Mei Guo

Published Mar 21, 2023• 14 citations
Publisher

Abstract

We build and characterize a dual-species all-optical magnetometer based on a Cs-K hybrid vapor cell with a paraffin coating. Using the amplitude-modulated Bell-Bloom scheme and Faraday-rotation measurement, we show that the spin polarization of Cs and K atoms can be generated and detected independently. The noise floor of the Cs channel is $35\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}$, whereas that of the K channel is $260\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}$, which is affected mainly by the magnetic resonance broadening in the presence of mutual spin-exchange collisions. With use of the proposed device, in situ magnetic field stabilization is realized by use of (i) the K channel to monitor and compensate for the magnetic field noise and (ii) the Cs channel to read out the magnetic field after active stabilization. The low-frequency magnetic field noise can be suppressed by a factor of more than $1000$ in the presence of magnetic field gradients. When applied to magnetic field stabilization, such in situ measurement is achieved more compactly and is more accurate than ex situ measurement that is realized with two spatially separated vapor cells. In addition, the proposed scheme could also be applied in a practical ground-surveying magnetometer based on dual working species.

DOI
10.1103/physrevapplied.19.034066

Related papers

Hybrid optical pumping of K and Rb atoms in a paraffin coated vapor cell

Wenhao Li, Xiang Peng, Dmitry Budker +4 more

Dynamic hybrid optical pumping effects with a radio-frequency field-driven nonlinear magneto-optical rotation scheme are studied in a dual-species paraffin coated vapor cell. By pumping K atoms and probing Rb87 atoms, we achieve an intrinsic magnetic resonance linewidth of 3 Hz, and the observed resonance is immune to power broadening and light-shift effects. Such an operation scheme shows favorable prospects for atomic magnetometry applications.

arXiv:1708.08605•Optics Letters•Oct 9, 2017•17 citations

In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers

Kaifeng Yin, Binquan Zhou, Jixi Lu +4 more

Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

IEEE Sensors Journal•Nov 30, 2021•15 citations

Hybrid pumping with dual detection: a novel comagnetometer for dual-axis magnetic field and rotation measurement

Jiale Quan, Wenfeng Fan, Longyan Ma +7 more

Abstract Quantum sensing has demonstrated exceptional potential in magnetic field and inertial rotation measurements due to its ultra-high sensitivity. Among various implementations, the spin-exchange relaxation-free comagnetometer, as atomic spin sensor, exhibits remarkable sensitivity and strong potential for miniaturization and integration. However, the low-frequency performance of such comagnetometers is fundamentally limited by intrinsic noise due to the coupling between magnetic field ( B ) and inertial rotation signals ( Ω ). In this paper, a novel dual spin-polarization detection scheme for a hybrid-pumping comagnetometer is proposed. By introducing simultaneous detection of two electron spin polarizations combined with longitudinal magnetic field modulation and demodulation, our approach enables decoupling and synchronous measurement of B and Ω . The proposed scheme is experimentally validated on a K–Rb- 21 Ne comagnetometer platform. Experimental results show that the two electron species demonstrate inconsistent behaviors in the self-compensation effect, with their respective self-compensation points occurring at different operating conditions. Finally, by individually calibrating the dual spin-polarization detection outputs, real-time in situ measurements of dual-axis magnetic fields and inertial rotation are achieved, effectively addressing the crosstalk issue between magnetic and inertial signals.

Measurement Science and Technology•Aug 5, 2026•0 citations

Dual channel self-oscillating optical magnetometer

Jacopo Belfi, G. Bevilacqua, V. Biancalana +4 more

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.

arXiv:0812.1160•Journal of the Optical Society of America B•Apr 3, 2009•30 citations

All-Optical Broadband Atomic Magnetometer Utilizing Raman-Driven Spin Noise Spectroscopy

Sayari Majumder, Saptarishi Chaudhuri

We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around$30~\text {pT}/\sqrt {\text {Hz}}$at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations

In-situ determination of spin polarization in a single-beam fiber-coupled spin-exchange-relaxation-free atomic magnetometer with differential detection

Yintao Ma, Zhixia Qiao, Yao Chen +8 more

The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.

Optics Express•Jan 9, 2023•5 citations
We build and characterize a dual-species all-optical magnetometer based on a Cs-K hybrid vapor cell with a paraffin coating. Using the amplitude-modulated Bell-Bloom scheme and Faraday-rotation measurement, we show that the spin polarization of Cs and K atoms can be generated and detected independently. The noise floor of the Cs channel is 35fT/Hz35\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}35fT/Hz​, whereas that of the K channel is 260fT/Hz260\phantom{\rule{0.2em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}260fT/Hz​, which is affected mainly by the magnetic resonance broadening in the presence of mutual spin-exchange collisions. With use of the proposed device, in situ magnetic field stabilization is realized by use of (i) the K channel to monitor and compensate for the magnetic field noise and (ii) the Cs channel to read out the magnetic field after active stabilization. The low-frequency magnetic field noise can be suppressed by a factor of more than 100010001000 in the presence of magnetic field gradients. When applied to magnetic field stabilization, such in situ measurement is achieved more compactly and is more accurate than ex situ measurement that is realized with two spatially separated vapor cells. In addition, the proposed scheme could also be applied in a practical ground-surveying magnetometer based on dual working species.
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.
Abstract Quantum sensing has demonstrated exceptional potential in magnetic field and inertial rotation measurements due to its ultra-high sensitivity. Among various implementations, the spin-exchange relaxation-free comagnetometer, as atomic spin sensor, exhibits remarkable sensitivity and strong potential for miniaturization and integration. However, the low-frequency performance of such comagnetometers is fundamentally limited by intrinsic noise due to the coupling between magnetic field ( B ) and inertial rotation signals ( Ω ). In this paper, a novel dual spin-polarization detection scheme for a hybrid-pumping comagnetometer is proposed. By introducing simultaneous detection of two electron spin polarizations combined with longitudinal magnetic field modulation and demodulation, our approach enables decoupling and synchronous measurement of B and Ω . The proposed scheme is experimentally validated on a K–Rb- 21 Ne comagnetometer platform. Experimental results show that the two electron species demonstrate inconsistent behaviors in the self-compensation effect, with their respective self-compensation points occurring at different operating conditions. Finally, by individually calibrating the dual spin-polarization detection outputs, real-time in situ measurements of dual-axis magnetic fields and inertial rotation are achieved, effectively addressing the crosstalk issue between magnetic and inertial signals.
We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D2 line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/sqrt Hz. This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm3.
We report the development and performance of an atomic magnetometer (AM) utilizing the Raman-driven spin noise spectroscopy (RDSNS) technique, which measures the intrinsic spin fluctuations of an atomic medium subjected to a coherent two-photon optical drive. The RDSNS signal is noninvasively detected using a far-off resonant weak probe light utilizing a polarimetric detection scheme. This overcomes the limitations of the small dynamic range and low bandwidth of traditional optically pumped magnetometers (OPMs) or AMs operating in the spin exchange relaxation-free (SERF) regime. We experimentally demonstrate, using both paraffin-coated and buffer-gas-filled vapor cell containing neutral rubidium atoms, that the dynamic range of such magnetometers can reach beyond 150 G while maintaining a dc magnetometer resolution of around 30 pT and a magnetic noise sensitivity of around30 pT/Hz30~\text {pT}/\sqrt {\text {Hz}}30 pT/Hz​at a bandwidth of 100 Hz and a magnetic field of about 0.6 mT. Being an all-optical setup, this instrument is largely immune to interference with stray radio frequency fields and has the potential to be miniaturized and field deployable. One of the practical applications would be to measure variations in geomagnetic fields precisely without having to shield the magnetometer.
The electronic spin polarization of alkali-metal-vapor atoms is a pivotal parameter for atomic magnetometers. Herein, a novel method is presented for determining the spin polarization with a miniaturized single-beam spin-exchange-relaxation-free (SERF) magnetometer on the basis of zero-field cross-over resonance. Two separate laser beams are utilized to heat the cell and interrogate the vapor atoms, respectively. Spin polarization can be extracted by measuring the resonance response signal of the magnetometer to the transverse magnetic field under different irradiances. Results of these experiments are consistent well with the theoretical predictions with the maximum deviation less than 4%. The proposed method has the integrated advantages of possessing a simple configuration and in-situ measurement. Furthermore, combined with a homemade optical differential detection system with a factor of approximately three of the power noise suppression, the developed single-beam SERF atomic magnetometer with a measuring sensitivity of 32 fT/Hz 1/2 has been achieved. This demonstrated approach can help guide the development of chip-scale atomic magnetometers for bio-magnetic field imaging applications.