Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Письма в журнал технической физики

Quantum noise source based on shot noise of a balanced photodetector with a tunable integrated optical beam splitter

В.В. Лебедев, V.M. Petrov, I. V. Ilichev, Peter M. Agruzov, А.В. Шамрай

Published Jan 1, 2022• 0 citations
Publisher

Abstract

A broadband quantum noise source based on detection of shot noise of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter constructed in the form of the dual output Mach-Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, the power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz. Keywords: quantum random number generator, vacuum fluctuations, shot noise measurements, integrated optics, lithium niobate

DOI
10.21883/tpl.2022.14.52066.18870

Related papers

Quantum Noise Source Based on Shot Noise of a Balanced Photodetector with a Tunable Integrated Optical Beam Splitter

Vladimir V. Lebedev, V. M. Petrov, Igor V. Il'ichev +2 more

Abstract A broadband quantum noise source based on detection of shot noise of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter constructed in the form of the dual output Mach–Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, the power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz.

Technical Physics Letters•Dec 1, 2023•1 citation

Источник квантового шума на основе детектирования дробового шума балансного фотоприемника с управляемым интегрально-оптическим светоделителем

В.В. Лебедев, В.М. Петров, Igor V. Il'ichev +2 more

Broadband quantum noise source based on the shot noise detection of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter in the form of the dual output Mach-Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz.

Письма в журнал технической физики•Jan 1, 2021•2 citations

Broadband Chip-Based Source of Quantum Noise with Electrically Controllable Beam Splitter

E. A. Vashukevich, Vladimir V. Lebedev, Igor V. Il'ichev +4 more

The theory and practical realization of a broadband quantum-noise generator based on an original integrated optical beam splitter in the form of a Mach-Zehnder interferometer is demonstrated. The beam splitter with a double output, made on a lithium niobate substrate, provides accurate electro-optical balancing of the homodyne quantum-noise detection circuit. The experimentally obtained excess of quantum noise over classical noise is 12 dB in the frequency band over 4 GHz, which is the best parameters of quantum-noise generators known from the literature.

arXiv:2109.09570•Physical Review Applied•Jun 22, 2022•6 citations

Quantum-limited operation of balanced mixer homodyne and heterodyne receivers

S. Machida, Y. Yamamoto

The quantum-limited operation of balanced mixer optical homodyne and heterodyne receiver using a 50-50 percent beam splitter and two identical photodetectors is experimentally confirmed. The absolute quantum noise levels are calibrated with an incoherent GaAs light-emitting diode output. The photoelectron statistics, obtained through the analog photon counting experiment, are reduced to the quantum limit. The photocurrent fluctuation spectral density measured with a spectrum analyzer also agrees with the quantum noise spectral density. Furthermore, the deviations from the absolute quantum noise level are within ±0.02 dB. Finally, complete suppression of local oscillator excess noise is demonstrated in the 0-1.5 GHz frequency region.

IEEE Journal of Quantum Electronics•May 1, 1986•48 citations

Effect of Classical Noise on Quantum Random Number Generation Based on Vacuum Fluctuation

Ken Tanizawa

A quantum random number generator (QRNG) utilizes quantum mechanical phenomena, such as photon superposition and vacuum fluctuation, to produce truly unpredictable random numbers. This study analyzes the effect of classical noise in a QRNG based on vacuum fluctuation, focusing on thermal noise and relative intensity noise (RIN) in an entropy source consisting of a laser source and balanced homodyne receiver. Numerical analysis shows that RIN significantly impacts QRNG performance when the error in the splitting ratio of a half beam splitter in the receiver exceeds 0.5 dB. This study indicates design guidelines for QRNG setups based on vacuum fluctuation.

•Feb 21, 2025•0 citations

Low-noise,Broadband Photo-detector Designs in Quantum Optics

Kuanshou Zhang

We report a kind of low-noise,broadband photo-detector that can be applied in the quantum optics experiments.Based on the proper photo-diode,sampling resistor,feedback resistor and capacity were selected,a low-noise,broadband photo-detector was designed and fabricated.The photo-detector can be used to detect the quantum noise with the band-width of 2-50 MHz and the incident power of up to 15 mW.It can also be applied in the quantum optics experiments such as balance detectors,homodyne detectors and so on.A pair of identical photo-detectors with the band-width of 2-31 MHz and Common Mode Rejection Ratio of 30 dB was used as balance detectors to measure the intensity noise of white light,cw single frequency 1064 nm laser and 1550 nm laser.

Acta Sinica Quantum Optica•Jan 1, 2010•2 citations
A broadband quantum noise source based on detection of shot noise of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter constructed in the form of the dual output Mach-Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, the power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz. Keywords: quantum random number generator, vacuum fluctuations, shot noise measurements, integrated optics, lithium niobate
Abstract A broadband quantum noise source based on detection of shot noise of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter constructed in the form of the dual output Mach–Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, the power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz.
Broadband quantum noise source based on the shot noise detection of a balanced photodetector is demonstrated. Precise electro-optical tuning of the balanced photodetector circuit was carried out by an integrated optical beam splitter in the form of the dual output Mach-Zehnder interferometer on a lithium niobate substrate. The classical component of the detected noise related to the relative intensity noise of a laser diode was suppressed by more than 15 dB. At the maximum laser power of 100 mW, power spectral density of detected shot noise was 12 dB higher than the level of technical noise of the measuring system in the frequency band above 3 GHz.
The theory and practical realization of a broadband quantum-noise generator based on an original integrated optical beam splitter in the form of a Mach-Zehnder interferometer is demonstrated. The beam splitter with a double output, made on a lithium niobate substrate, provides accurate electro-optical balancing of the homodyne quantum-noise detection circuit. The experimentally obtained excess of quantum noise over classical noise is 12 dB in the frequency band over 4 GHz, which is the best parameters of quantum-noise generators known from the literature.
The quantum-limited operation of balanced mixer optical homodyne and heterodyne receiver using a 50-50 percent beam splitter and two identical photodetectors is experimentally confirmed. The absolute quantum noise levels are calibrated with an incoherent GaAs light-emitting diode output. The photoelectron statistics, obtained through the analog photon counting experiment, are reduced to the quantum limit. The photocurrent fluctuation spectral density measured with a spectrum analyzer also agrees with the quantum noise spectral density. Furthermore, the deviations from the absolute quantum noise level are within ±0.02 dB. Finally, complete suppression of local oscillator excess noise is demonstrated in the 0-1.5 GHz frequency region.
A quantum random number generator (QRNG) utilizes quantum mechanical phenomena, such as photon superposition and vacuum fluctuation, to produce truly unpredictable random numbers. This study analyzes the effect of classical noise in a QRNG based on vacuum fluctuation, focusing on thermal noise and relative intensity noise (RIN) in an entropy source consisting of a laser source and balanced homodyne receiver. Numerical analysis shows that RIN significantly impacts QRNG performance when the error in the splitting ratio of a half beam splitter in the receiver exceeds 0.5 dB. This study indicates design guidelines for QRNG setups based on vacuum fluctuation.
We report a kind of low-noise,broadband photo-detector that can be applied in the quantum optics experiments.Based on the proper photo-diode,sampling resistor,feedback resistor and capacity were selected,a low-noise,broadband photo-detector was designed and fabricated.The photo-detector can be used to detect the quantum noise with the band-width of 2-50 MHz and the incident power of up to 15 mW.It can also be applied in the quantum optics experiments such as balance detectors,homodyne detectors and so on.A pair of identical photo-detectors with the band-width of 2-31 MHz and Common Mode Rejection Ratio of 30 dB was used as balance detectors to measure the intensity noise of white light,cw single frequency 1064 nm laser and 1550 nm laser.