Optical and Quantum Sensing and Precision Metrology II

Experimental source separation estimation reaching the Cramér-Rao bound

David Barral, Clémentine Rouvière, Antonin Grateau, Ilya Karuseichyk, Giacomo Sorelli, Manuel Gessner, Mattia Walschaers, Nicolas Treps

Published Mar 8, 2023• 0 citations
Publisher

Abstract

We experimentally implement the separation estimation between to incoherent optical sources. Our method, relying on spatial-mode demultiplexing and intensity measurements, saturates the Cramèr-Rao bound, with a five orders of magnitude gain compared to the Rayleigh limit.
DOI
10.1117/12.2657172

Related papers

Experimental Separation Estimation of Incoherent Optical Sources Reaching the Cramér-Rao Bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation

Experimental separation estimation of incoherent optical sources reaching the (quantum) Cramér-Rao bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Photonics North (PN)•Jun 12, 2023•0 citations

Ultra-sensitive separation estimation of optical sources

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrology-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite–Gauss basis. Analyzing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.

arXiv:2306.11916•Optica•Nov 10, 2023•51 citations

Parameter estimation approach to super resolution

Alexander Boeschoten, Antonin Grateau, Clémentine Rouvière +7 more

The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations

Multiparameter estimation for the superresolution of two incoherent sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +2 more

We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.

quant-pharXiv:2601.14876•Physical Review Letters•Jan 22, 2026•2 citations

Rayleigh’s Criterion is Irrelevant to the Localization of Two Incoherent Optical Point Sources

Mankei Tsang, Ranjith Nair, Xiao-Ming Lu

Using the quantum Cramer-Rao bound, we prove that Rayleigh's criterion is fundamentally irrelevant to the estimation of the separation between two incoherent optical sources. We also propose measurement schemes that attain the bound.

Conference on Lasers and Electro-Optics•Jan 1, 2016•0 citations
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].
Historically, the resolution of optical imaging systems was dictated by diffraction, and the Rayleigh criterion was long considered an unsurpassable limit. In superresolution microscopy, this limit is overcome by manipulating the emission properties of the object. However, in passive imaging, when sources are uncontrolled, reaching sub-Rayleigh resolution remains a challenge. Here, we implement a quantum-metrology-inspired approach for estimating the separation between two incoherent sources, achieving a sensitivity five orders of magnitude beyond the Rayleigh limit. Using a spatial mode demultiplexer, we examine scenes with bright and faint sources, through intensity measurements in the Hermite–Gauss basis. Analyzing sensitivity and accuracy over an extensive range of separations, we demonstrate the remarkable effectiveness of demultiplexing for sub-Rayleigh separation estimation. These results effectively render the Rayleigh limit obsolete for passive imaging.
The resolution of optical systems, formulated as the smallest possible distance between two point sources for which they still can be dissolved, was for a long time believed to be limited by diffraction, formulated by the Rayleigh criterion. Recent advancements in quantum metrology have shown, by evaluation of the Quantum Cramér Rao bound (QCRB), that the Rayleigh criterion is not a fundamental limit. In our experiment, spatial mode demultiplexing (SPADE) is used to estimate the separation of the sources orders of magnitude below the Rayleigh limit. The experiment is extended to incorporate the measurement of additional parameters, such as power imbalance and centroid position of the two sources, bringing it closer to real-world applicability.
We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.