A major and ongoing focus of our research effort has been the development of laser pulse sequences analogous to those used in nuclear magnetic resonance, to study relaxation phenomena in condensed phases. Sequences of multiple rectangular 90° and 180° pulses with various phases have been used extensively in high resolution and solid state NMR for nearly three decades, and have been shown to enhance forbidden transitions, selectively refocus some intermolecular interactions, or even increase physiological image contrast for tumor identification. By contrast, the conventional approach to optical coherent transient spectroscopy (splitting a single high power pulse into several parts) generates pulse sequences with well defined delays, but generally totally unknown phases; in addition, the pulse shape is not easily controlled. This approach has proven extremely useful in the past, particularly if noncollinear pulses are used to exploit propagation effects, but growing recognition of the fundamental complexity of condensed phase relaxation processes (and the defects of a two-level approximation) reveals a fundamental need for a more powerful approach.
In this series of papers we report on the generation and application of multiple pulse phase coherent sequences in optical spectroscopy.In this paper the effects of intense pulse trains on systems with only two resonant energy levels are analyzed, with particular attention to the effects of extreme inhomogeneous broadening and population depletion to nonresonant levels.It is shown that these effects, which are present in virtually all optical systems, make the simple gyroscopic model of optical coherent transients invalid.Exact calculations show, e.g., that a two-pulse photon echo is not maximized by a 1:2 length ratio for the pulses; that the maximum excited state population is not created by a 180" pulse; and that three equal pulses are almost as effective as a 1:2:1 ratio for producing three pulse echoes.The role of pulse phase is extensively analyzed.Pulse sequences are proposed and experimentally demonstrated which permit optical phase sensitive detection and measurement of ground state relaxation parameters.The experimental results are based on an extension of the acousto-optic modulation and fluoresence detection techniques of Zewail and Orlowski [Zewail et al., Chem.Phys.Lett.48, 256 (1977); Orlowski et al., ibid.54, 197 (1978)).The relative merits offluorescence and transverse polarization detection are discussed, and fluorescence detection is shown to be more generally useful for these new sequences.Finally, composite pulse trains are shown to be capable of substantially increasing the signal available from highly inhomogenously broadened transitions.In paper II we extend the treatment to multilevel systems with some emphasis on solid state applications.
In this series of papers we report on the generation and application of multiple pulse phase coherent sequences in optical spectroscopy. In this paper the effects of intense pulse trains on systems with only two resonant energy levels are analyzed, with particular attention to the effects of extreme inhomogeneous broadening and population depletion to nonresonant levels. It is shown that these effects, which are present in virtually all optical systems, make the simple gyroscopic model of optical coherent transients invalid. Exact calculations show, e.g., that a two-pulse photon echo is not maximized by a 1:2 length ratio for the pulses; that the maximum excited state population is not created by a 180° pulse; and that three equal pulses are almost as effective as a 1:2:1 ratio for producing three pulse echoes. The role of pulse phase is extensively analyzed. Pulse sequences are proposed and experimentally demonstrated which permit optical phase sensitive detection and measurement of ground state relaxation parameters. The experimental results are based on an extension of the acousto-optic modulation and fluoresence detection techniques of Zewail and Orlowski [Zewail et al., Chem. Phys. Lett. 48, 256 (1977); Orlowski et al., ibid. 54, 197 (1978)]. The relative merits of fluorescence and transverse polarization detection are discussed, and fluorescence detection is shown to be more generally useful for these new sequences. Finally, composite pulse trains are shown to be capable of substantially increasing the signal available from highly inhomogenously broadened transitions. In paper II we extend the treatment to multilevel systems with some emphasis on solid state applications.
Early in the study of nuclear magnetic resonance, it was recognized that coherent transient signals could possess shapes highly correlated with the radio frequency pulses used to generate them.1 Similar results were observed in the case of optical coherent transients.2 The information necessary to recreate the excitation pulse shapes has traditionally been seen to reside in the polarization of the sample or in the population difference between two energy states. Information so stored is constrained to relax at rates determined by the transverse T2 or the longitudinal T1, relaxation times of the excited nuclear or optical transition. Owing to the shortness of T1 and T2, coherent transient pulse shape storage has been viewed previously as having limited utility.
Optical spectroscopy using ultrafast light pulses has undergone a revolution in the last decade due to the introduction and development of multidimensional coherent techniques. These methods build on established coherent spectroscopic techniques, such as photon echoes, but go beyond them by correlating the coherent dynamics during two time periods. The resulting multidimensional spectra have a number of advantages including disentangling congested spectra, revealing coupling between resonances, and removing the effects of inhomogeneous broadening. Similar ideas are currently being used for imaging. The papers in this 'focus on' collection document some of the current areas of activity in these fields.
A new method of picosecond and femtosecond transient spectroscopy yielding information about ultrafast relaxation processes without requiring ultrashort light pulses is presented. It is based on the present theoretical analysis of the resonant degenerate four-wave-mixing process excited by two temporally incoherent light beams with wave vectors ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ and ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}$ which are originated from a single beam at frequency $\ensuremath{\omega}$ but have mutual time delay $\ensuremath{\tau}$. Under the assumption that the incoherent light field has Gaussian random complex amplitude and that the resonant material consists of the usual two-level atoms, the statistically averaged intensity of the output light field with ${\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{3}=2{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{2}\ensuremath{-}{\stackrel{\ensuremath{\rightarrow}}{\mathrm{k}}}_{1}$ at $\ensuremath{\omega}$ is calculated as a function of $\ensuremath{\tau}$. Even with the light having a much longer duration than both
T1 (the longitudinal relaxation time) and
T2 (the transverse relaxation time), the correlation trace, i.e., output intensity versus $\ensuremath{\tau}$, represents a decay profile determined mainly by
T2 for both homogeneously and inhomogeneously broadened transitions, as long as the light correlation time ${\ensuremath{\tau}}_{c}$ is much shorter than the relaxation times. The correlation trace does not always represent a single-exponential decay but is sometimes slightly deformed by the
T1 effect. However, it does not cause a significant error in the determination of
T2. Moreover, as $\frac{{T}_{2}}{{T}_{1}}\ensuremath{\rightarrow}0$, the trace becomes a single-exponential decay curve determined only by
T2. The feature of the results obtained by the present method is similar to that obtained by the conventional coherent transient spectroscopy with short pulses, such as the photon echo. The time resolution in the present method, however, is limited only by ${\ensuremath{\tau}}_{c}$ much shorter than the light duration. By regarding the incoherent light as a series of random ultrashort pulses, the present four-wave-mixing process is also interpreted as the ensemble of numerous transient four-wave-mixing processes caused by various combinations of these pulses.